Graphic analysis of energy and exergy combined systems of solar collector and high-temperature heat pump

被引:2
|
作者
Shoeibi, Habib [1 ]
Mehrpooya, Mehdi [1 ,2 ]
Assaerh, Ehsanolah [1 ]
Izadi, Mohsen [1 ,3 ]
Pourfayaz, Fathollah [1 ,2 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, Dezful Branch, Dezful, Iran
[2] Univ Tehran, Fac New Sci & Technol, Renewable Energies & Environm Dept, Tehran, Iran
[3] Lorestan Univ, Fac Engn, Mech Engn Dept, Khorramabad, Iran
关键词
Graphic analysis; Exergy; Combined systems; Solar collector; High-temperature; Heat pump; NGL RECOVERY; MULTIOBJECTIVE OPTIMIZATION; REFRIGERATION CYCLES; SANKEY DIAGRAM; PLANT; HYBRID; ABSORPTION; WATER;
D O I
10.1007/s11696-022-02536-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study investigated the heat pump system connected to the solar collector. The purpose of this study is to determine the amount of energy consumption and exergy and system performance. This system uses high-temperature heat pumps. In this paper, energy-based and exergy currents from the primary energy source to the consumer are plotted by using Sankey and Grassmann diagrams. In this article, Sankey (enthalpy flow) and Grassmann (exergy flow) diagrams of a heat pump connected to a solar collector were investigated. The results show that stream number 12 has the highest amount of exergy of the streams and the exergy destruction of the solar collector is more than other equipment and the highest energy rate is related to stream 11. Exergy analysis in thermal energy systems is very important due to the location and degree of inefficiency of the system equipment. Exergy analysis shows that the highest amount of exergy of currents with 367,092 kW is related to the inlet current of the tank and the highest amount of exergy damage of 15,563 kW equipments is related to the solar collector. This exergy destruction for solar collectors with temperature changes throughout the year with the lowest destruction in July at 14,342 kW and the highest exergy destruction at 15,678 kW is related to June. Among the rotating equipments, the most exergy damage is related to the compressor (k101) water heat transfer cycle. By changing the exergy efficiency, the amount of exergy destruction is significantly reduced.
引用
收藏
页码:1149 / 1164
页数:16
相关论文
共 50 条
  • [41] Exergy analysis and optimization of a solar-assisted heat pump
    Reyes, ET
    Nunez, MP
    Cervantes, J
    ENERGY, 1998, 23 (04) : 337 - 344
  • [42] Energy, exergy, economic and environmental analyses and optimization of a novel vapor injection autocascade heat pump for high-temperature water heating
    Chen, Jiaheng
    Chen, Qi
    Qin, Xiang
    Wang, Dingbiao
    ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [43] Energy and exergy efficiency analysis of solar driven ejector-compressor heat pump cycle
    Yan, Gang
    Bai, Tao
    Yu, Jianlin
    SOLAR ENERGY, 2016, 125 : 243 - 255
  • [44] Performance characteristics and energy-exergy analysis of solar-assisted heat pump system
    Dikici, Aydin
    Akbulut, Abdullah
    BUILDING AND ENVIRONMENT, 2008, 43 (11) : 1961 - 1972
  • [45] An Energy and Exergy Analysis of Water and Air with Different Passage in a Solar Collector
    Assari, M. R.
    Tabrizi, H. Basirat
    Jafari, I.
    Najafpour, E.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2014, 36 (07) : 747 - 754
  • [46] Performance Analysis of a Thermoelectric Solar Collector Integrated with a Heat Pump
    Lertsatitthanakorn, C.
    Jamradloedluk, J.
    Rungsiyopas, M.
    Therdyothin, A.
    Soponronnarit, S.
    JOURNAL OF ELECTRONIC MATERIALS, 2013, 42 (07) : 2320 - 2325
  • [47] Performance Analysis of a Thermoelectric Solar Collector Integrated with a Heat Pump
    C. Lertsatitthanakorn
    J. Jamradloedluk
    M. Rungsiyopas
    A. Therdyothin
    S. Soponronnarit
    Journal of Electronic Materials, 2013, 42 : 2320 - 2325
  • [48] Performance analysis of different high-temperature heat pump systems for low-grade waste heat recovery
    Cao, Xing-Qi
    Yang, Wei-Wei
    Zhou, Fu
    He, Ya-Ling
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 291 - 300
  • [49] EXERGY ANALYSIS OF A LOW-TEMPERATURE HEAT-PUMP
    RANGREJ, HA
    NARAYANKHEDKAR, KG
    CRYOGENICS, 1983, 23 (03) : 148 - 150
  • [50] HIGH-TEMPERATURE HEAT-PUMP FLUIDS