Graphic analysis of energy and exergy combined systems of solar collector and high-temperature heat pump

被引:2
|
作者
Shoeibi, Habib [1 ]
Mehrpooya, Mehdi [1 ,2 ]
Assaerh, Ehsanolah [1 ]
Izadi, Mohsen [1 ,3 ]
Pourfayaz, Fathollah [1 ,2 ]
机构
[1] Islamic Azad Univ, Dept Mech Engn, Dezful Branch, Dezful, Iran
[2] Univ Tehran, Fac New Sci & Technol, Renewable Energies & Environm Dept, Tehran, Iran
[3] Lorestan Univ, Fac Engn, Mech Engn Dept, Khorramabad, Iran
关键词
Graphic analysis; Exergy; Combined systems; Solar collector; High-temperature; Heat pump; NGL RECOVERY; MULTIOBJECTIVE OPTIMIZATION; REFRIGERATION CYCLES; SANKEY DIAGRAM; PLANT; HYBRID; ABSORPTION; WATER;
D O I
10.1007/s11696-022-02536-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study investigated the heat pump system connected to the solar collector. The purpose of this study is to determine the amount of energy consumption and exergy and system performance. This system uses high-temperature heat pumps. In this paper, energy-based and exergy currents from the primary energy source to the consumer are plotted by using Sankey and Grassmann diagrams. In this article, Sankey (enthalpy flow) and Grassmann (exergy flow) diagrams of a heat pump connected to a solar collector were investigated. The results show that stream number 12 has the highest amount of exergy of the streams and the exergy destruction of the solar collector is more than other equipment and the highest energy rate is related to stream 11. Exergy analysis in thermal energy systems is very important due to the location and degree of inefficiency of the system equipment. Exergy analysis shows that the highest amount of exergy of currents with 367,092 kW is related to the inlet current of the tank and the highest amount of exergy damage of 15,563 kW equipments is related to the solar collector. This exergy destruction for solar collectors with temperature changes throughout the year with the lowest destruction in July at 14,342 kW and the highest exergy destruction at 15,678 kW is related to June. Among the rotating equipments, the most exergy damage is related to the compressor (k101) water heat transfer cycle. By changing the exergy efficiency, the amount of exergy destruction is significantly reduced.
引用
收藏
页码:1149 / 1164
页数:16
相关论文
共 50 条
  • [31] HIGH-TEMPERATURE SOLAR-ENERGY CONVERSION SYSTEMS
    PRICE, KM
    SOLAR ENERGY, 1980, 25 (02) : 187 - 189
  • [32] PERFORMANCE OF A COMBINED SOLAR AIR COLLECTOR AND HEAT-PUMP SYSTEM
    DEHON, P
    DETHYSEBAERT, D
    BOUSSARD, H
    REVUE DE L AGRICULTURE, 1988, 41 (03): : 689 - 700
  • [33] Performance simulation of combined heat pump with unglazed transpired solar collector
    Safijahanshahi, Esmaeel
    Salmanzadeh, Mazyar
    SOLAR ENERGY, 2019, 180 : 575 - 593
  • [34] High Temperature Heat Pump with Combined Cooling, Heat and Power Plant in Industrial Buildings: An Energy Analysis
    Noro, Marco
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (03) : 489 - 497
  • [35] Solar combined cycle with high-temperature thermochemical energy storage
    Ortiz, C.
    Tejada, C.
    Chacartegui, R.
    Bravo, R.
    Carro, A.
    Valverde, J. M.
    Valverde, J.
    ENERGY CONVERSION AND MANAGEMENT, 2021, 241
  • [36] Energy and exergy analysis of thermoelectric heat pump system
    Kaushik, S. C.
    Manikandan, S.
    Hans, Ranjana
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 86 : 843 - 852
  • [37] Energy and Exergy Analysis of an Annular Thermoelectric Heat Pump
    S. C. Kaushik
    S. Manikandan
    Ranjana Hans
    Journal of Electronic Materials, 2016, 45 : 3400 - 3409
  • [38] Energy analysis of a thermal system composed by a heat pump coupled with a PVT solar collector
    Vallati, A.
    Oclon, P.
    Colucci, C.
    Mauri, L.
    Vollaro, R. de Lieto
    Taler, J.
    ENERGY, 2019, 174 : 91 - 96
  • [39] Optimal operating temperature of solar collector for irreversible solar heat pump system
    Lin, Guoxing
    Yan, Zijun
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1996, 17 (04): : 371 - 375
  • [40] Performance analysis of multistage high-temperature heat pump cycle
    Kim, Seon Tae
    Hegner, Robert
    Oezuylasi, Goeksel
    Stathopoulos, Panagiotis
    Nicke, Eberhard
    ENERGY SCIENCE & ENGINEERING, 2023, 11 (10) : 3500 - 3511