Benchmarking the Effects on Human-Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control

被引:6
|
作者
Rodrigues-Carvalho, Camila [1 ,2 ]
Fernandez-Garcia, Marvin [3 ]
Pinto-Fernandez, David [1 ,4 ]
Sanz-Morere, Clara [5 ]
Barroso, Filipe Oliveira [1 ]
Borromeo, Susana [3 ]
Rodriguez-Sanchez, Cristina [3 ]
Moreno, Juan C. [1 ]
del-Ama, Antonio J. [3 ]
机构
[1] CSIC, Cajal Inst, Neural Rehabil Grp, Madrid 28002, Spain
[2] Carlos III Univ Madrid, Syst Engn & Automat Dept, Madrid 28903, Spain
[3] Rey Juan Carlos Univ, Elect Technol Dept, Mostoles 28933, Spain
[4] Univ Politecn Madrid, CAR UPM Associated Unit, Madrid 28040, Spain
[5] Hosp Los Madronos, Ctr Clin Neurosci, Madrid 28690, Spain
基金
欧盟地平线“2020”;
关键词
exoskeleton; human-robot interaction; electromyography; EMG control; exoskeleton control; benchmarking; MUSCLE-ACTIVITY; ROBOT; NEUROREHABILITATION; REDUCTION; ROBUST; ONSET;
D O I
10.3390/s23020791
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH's protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human-exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Impedance Reduction Control of a Knee Joint Human-Exoskeleton System
    Huo, Weiguang
    Mohammed, Samer
    Amirat, Yacine
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2019, 27 (06) : 2541 - 2556
  • [22] Minimizing human-exoskeleton interaction force by using global fast sliding mode control
    Duong Mien Ka
    Cheng Hong
    Tran Huu Toan
    Jing Qiu
    International Journal of Control, Automation and Systems, 2016, 14 : 1064 - 1073
  • [23] Modeling and Identification of the Human-Exoskeleton Interaction Dynamics for Upper Limb Rehabilitation
    Wang, Xiaofeng
    Li, Xing
    Wang, Jianhui
    PROCEEDINGS OF THE 2015 CHINESE INTELLIGENT AUTOMATION CONFERENCE: INTELLIGENT TECHNOLOGY AND SYSTEMS, 2015, 338 : 51 - 60
  • [24] Reducing the Human-Exoskeleton Interaction Force Using Bionic Design of Joints
    Yang, Wei
    Yang, Canjun
    Wei, Qianxiao
    Zhu, Minhang
    WEARABLE SENSORS AND ROBOTS, 2017, 399 : 195 - 209
  • [25] Variable Admittance Control of High Compatibility Exoskeleton Based on Human–Robotic Interaction Force
    Jian Cao
    Jianhua Zhang
    Chang Wang
    Kexiang Li
    Jianjun Zhang
    Guihua Wang
    Hongliang Ren
    Chinese Journal of Mechanical Engineering, 2024, 37 (05) : 428 - 442
  • [26] Study on the Control Method of Knee Joint Human-Exoskeleton Interactive System
    Wang, Zhipeng
    Yang, Chifu
    Ding, Zhen
    Yang, Tao
    Guo, Hao
    Jiang, Feng
    Tian, Bowen
    SENSORS, 2022, 22 (03)
  • [27] Human-exoskeleton control simulation, kinetic and kinematic modeling and parameters extraction
    Khamar, Maryam
    Edrisi, Mehdi
    Zahiri, Mohsen
    METHODSX, 2019, 6 : 1838 - 1846
  • [28] Effects Of Overground-based Versus Treadmill-based Exoskeleton Training Protocols On Human-exoskeleton Performance
    Kao, Pei-Chun
    Cring, Charles H.
    Norton, Adam
    Seay, Joseph F.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 582 - 583
  • [29] A Bionic Control Method for Human-Exoskeleton Coupling Based on CPG Model
    Sun, Tianyi
    Zhang, Shujun
    Li, Ruiqi
    Yan, Yao
    ACTUATORS, 2023, 12 (08)
  • [30] Adaptive Admittance Control for an Ankle Exoskeleton Using an EMG-Driven Musculoskeletal Model
    Yao, Shaowei
    Zhuang, Yu
    Li, Zhijun
    Song, Rong
    FRONTIERS IN NEUROROBOTICS, 2018, 12