Variable Admittance Control of High Compatibility Exoskeleton Based on Human–Robotic Interaction Force

被引:0
|
作者
Jian Cao [1 ]
Jianhua Zhang [2 ]
Chang Wang [2 ]
Kexiang Li [3 ]
Jianjun Zhang [1 ]
Guihua Wang [1 ]
Hongliang Ren [4 ]
机构
[1] School of Mechanical Engineering, Hebei University of Technology
[2] School of Mechanical Engineering, University of Science and Technology Beijing
[3] School of Mechanical and Materials Engineering, North China University of Technology
[4] Department of Electronic Engineering, The Chinese University of Hong
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The wearable exoskeleton system is a typical strongly coupled human–robotic system. Human–robotic is the environment for each other. The two support each other and compete with each other. Achieving high human–robotic compatibility is the most critical technology for wearable systems. Full structural compatibility can improve the intrinsic safety of the exoskeleton, and precise intention understanding and motion control can improve the comfort of the exoskeleton. This paper first designs a physiologically functional bionic lower limb exoskeleton based on the study of bone and joint functional anatomy and analyzes the drive mapping model of the dual closedloop four-link knee joint. Secondly, an exoskeleton dual closed-loop controller composed of a position inner loop and a force outer loop is designed. The inner loop of the controller adopts the PID control algorithm, and the outer loop adopts the adaptive admittance control algorithm based on human–robot interaction force(HRI). The controller can adaptively adjust the admittance parameters according to the HRI to respond to dynamic changes in the mechanical and physical parameters of the human–robot system, thereby improving control compliance and the wearing comfort of the exoskeleton system. Finally, we built a joint simulation experiment platform based on SolidWorks/Simulink to conduct virtual prototype simulation experiments and recruited volunteers to wear rehabilitation exoskeletons to conduct related control experiments. Experimental results show that the designed physiologically functional bionic exoskeleton and adaptive admittance controller can significantly improve the accuracy of human–robotic joint motion tracking, effectively reducing human–machine interaction forces and improving the comfort and safety of the wearer. This paper proposes a dual-closed loop four-link knee joint exoskeleton and a variable admittance control method based on HRI, which provides a new method for the design and control of exoskeletons with high compatibility.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Variable Admittance Control of High Compatibility Exoskeleton Based on Human–Robotic Interaction Force
    Cao, Jian
    Zhang, Jianhua
    Wang, Chang
    Li, Kexiang
    Zhang, Jianjun
    Wang, Guihua
    Ren, Hongliang
    [J]. Chinese Journal of Mechanical Engineering (English Edition), 2024, 37 (01):
  • [2] Admittance Control of a Robotic Exoskeleton for Physical Human Robot Interaction
    Huang, Bo
    Ye, Zhifeng
    Li, Zhijun
    Yuan, Wang
    Yang, Chenguang
    [J]. 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM), 2017, : 245 - 250
  • [3] Ankle flexible exoskeleton based on force feedback admittance control
    Chen, Dong
    Li, Weida
    Zhang, Hongmiao
    Li, Juan
    [J]. Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2024, 58 (04): : 772 - 778
  • [4] Adaptive Admittance Control Strategy for a Robotic Knee Exoskeleton With a Nonlinear Variable Stiffness Actuator
    Chen, Bing
    Zhou, Lei
    Zi, Bin
    Li, Eric
    Zhang, Dan
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2024,
  • [5] Physical Human-Robot Interaction of a Robo is Exoskeleton By Admittance Control
    Li, Zhijun
    Huang, Bo
    Ye, Zhifeng
    Deng, Mingdi
    Yang, Chenguang
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (12) : 9614 - 9624
  • [6] Variable admittance control of the exoskeleton for gait rehabilitation based on a novel strength metric
    Taherifar, Ali
    Vossoughi, Gholamreza
    Ghafari, Ali Selk
    [J]. ROBOTICA, 2018, 36 (03) : 427 - 447
  • [7] Predictive Optimization of Assistive Force in Admittance Control-Based Physical Interaction for Robotic Gait Assistance
    Itadera, Shunki
    Dean-Leon, Emmanuel
    Nakanishi, Jun
    Hasegawa, Yasuhisa
    Cheng, Gordon
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2019, 4 (04): : 3609 - 3616
  • [8] Dynamical system based variable admittance control for physical human-robot interaction
    Bian, Feifei
    Ren, Danmei
    Li, Ruifeng
    Liang, Peidong
    Wang, Ke
    Zhao, Lijun
    [J]. Industrial Robot, 2021, 47 (04): : 623 - 635
  • [9] Dynamical system based variable admittance control for physical human-robot interaction
    Bian, Feifei
    Ren, Danmei
    Li, Ruifeng
    Liang, Peidong
    Wang, Ke
    Zhao, Lijun
    [J]. INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2020, 47 (04): : 623 - 635
  • [10] Variable Admittance Control of a Hand Exoskeleton for Virtual Reality-Based Rehabilitation Tasks
    Topini, Alberto
    Sansom, William
    Secciani, Nicola
    Bartalucci, Lorenzo
    Ridolfi, Alessandro
    Allotta, Benedetto
    [J]. FRONTIERS IN NEUROROBOTICS, 2022, 15