Modified Fukuda stepping motion assessment of young healthy adults using portable inertial measurement units

被引:2
|
作者
Miwa, Toru [1 ,2 ]
Yasuda, Tomohisa [3 ]
Kouga, Teppei [1 ]
Sunami, Kishiko [1 ]
机构
[1] Osaka Metropolitan Univ, Dept Otolaryngol Head & Neck Surg, 1-4-3 Asahi-machi, Abeno-ku, Osaka 5458585, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Otolaryngol Head & Neck Surg, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 6068507, Japan
[3] Yasuda ENT Clin, 1-1-1 TakarOachi, Katsusika-ku, Tokyo 1240005, Japan
关键词
Foulage test; Inertial measurement unit; Micro-electromechanical system; Modified fukuda stepping test; Multivariable regression analysis; Sensing technologies; Six-axis motion sensor; ACCELEROMETRY; ORIENTATION; BALANCE; GAIT; EYE;
D O I
10.1016/j.heliyon.2023.e15018
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Currently, vestibular rehabilitation approaches used to monitor body position and movement during rehabilitation training require specialized equipment or rely on clinician observation. Thus, a simpler position-sensing approach that can be used to monitor movement during vestibular rehabilitation is required. This study used wearable motion sensors with built-in ac-celerometers and gyrometers to assess movement in adults. We explored stepping patterns in adults using this motion-sensing system. Six healthy adults (men, age 27.3 +/- 5.8 years) under-went a modified Fukuda stepping test (Foulage test [FT]) while wearing a six-axis motion sensor (accelerometer: X-axis, Y-axis, Z-axis; gyrometer: X-axis, Y-axis, Z-axis) positioned at the head, thorax, and lumbar spine. For motion sensor parameters, we calculated the root mean square (RMS), autocorrelation coefficient (AC), power spectrum (PS) of the AC, and Euler angles from the six-axis motion sensor. For the FT parameters, the FT value, step variance, and theta values were calculated. Data were analyzed, and multivariable regression analysis was performed using the FT value, step variance, and theta value as the dependent variables to investigate their influence on dynamic equilibrium. The explanatory variables included the motion sensor parameters, RMS, AC, and PS. Our results suggested that almost no head and lumbar spine movement occurred while stepping with eyes open. Contrastingly, the head and lumbar spine swayed with eyes closed. This accelerometric and gyroscopic device is easy to use, does not require specialized equipment, and can be used to analyze performance in the modified Fukuda stepping test in clinical practice. Inertial sensors have many advantages over other sensing technologies.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Quantification of Compensatory Torso Motion in Post-Stroke Patients Using Wearable Inertial Measurement Units
    Nguyen, Golda
    Maclean, Julie
    Stirling, Leia
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 15349 - 15360
  • [42] Low-cost real-time motion capturing system using inertial measurement units
    Salicone, Simona
    Corbellini, Simone
    Jetti, Harsha Vardhana
    Ronaghi, Sina
    ACTA IMEKO, 2022, 11 (03):
  • [43] Reliability of motion phase identification for long-track speed skating using inertial measurement units
    Iizuka, Tomoki
    Tomita, Yosuke
    PEERJ, 2024, 12
  • [44] Assessment of spatio-temporal gait parameters using inertial measurement units in neurological populations
    Esser, Patrick
    Dawes, Helen
    Collett, Johnny
    Feltham, Max G.
    Howells, Ken
    GAIT & POSTURE, 2011, 34 (04) : 558 - 560
  • [45] Improving Modified Tardieu Scale Assessment using Inertial Measurement Unit with Visual Biofeedback
    Choi, Seoyoung
    Kim, Jonghyun
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4703 - 4706
  • [46] Motion quality in rotator cuff tear using an inertial measurement unit: new parameters for dynamic motion assessment
    Kwak, Jae-Man
    Ha, Tae-Hyun
    Sun, Yucheng
    Kholinne, Erica
    Koh, Kyoung-Hwan
    Jeon, In-Ho
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (03) : 593 - 599
  • [47] Proposed Mobility Assessments with Simultaneous Full-Body Inertial Measurement Units and Optical Motion Capture in Healthy Adults and Neurological Patients for Future Validation Studies: Study Protocol
    Warmerdam, Elke
    Romijnders, Robbin
    Geritz, Johanna
    Elshehabi, Morad
    Maetzler, Corina
    Otto, Jan Carl
    Reimer, Maren
    Stuerner, Klarissa
    Baron, Ralf
    Paschen, Steffen
    Beyer, Thorben
    Dopcke, Denise
    Eiken, Tobias
    Ortmann, Hendrik
    Peters, Falko
    von der Recke, Felix
    Riesen, Moritz
    Rohwedder, Gothia
    Schaade, Anna
    Schumacher, Maike
    Sondermann, Anton
    Maetzler, Walter
    Hansen, Clint
    SENSORS, 2021, 21 (17)
  • [48] Quantifying shoulder motion in the free-living environment using wearable inertial measurement units: Challenges and recommendations
    Cain, Stephen M.
    Morrow, Melissa M. B.
    JOURNAL OF BIOMECHANICS, 2025, 182
  • [49] Using wireless inertial measurement units for measuring hip range of motion through commonly used clinical tests
    Oliva-Lozano, Jose M.
    Martin-Fuentes, Isabel
    Muyor, Jose M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2022,
  • [50] Gait Analysis Based on an Inertial Measurement Unit Sensor: Validation of Spatiotemporal Parameters Calculation in Healthy Young and Older Adults
    Sugiarto, Tommy
    Lin, Yi-Jia
    Chang, Chao-Chin
    Hsu, Wei-Chun
    2017 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2017, : 517 - 522