Modified Fukuda stepping motion assessment of young healthy adults using portable inertial measurement units

被引:2
|
作者
Miwa, Toru [1 ,2 ]
Yasuda, Tomohisa [3 ]
Kouga, Teppei [1 ]
Sunami, Kishiko [1 ]
机构
[1] Osaka Metropolitan Univ, Dept Otolaryngol Head & Neck Surg, 1-4-3 Asahi-machi, Abeno-ku, Osaka 5458585, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Otolaryngol Head & Neck Surg, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 6068507, Japan
[3] Yasuda ENT Clin, 1-1-1 TakarOachi, Katsusika-ku, Tokyo 1240005, Japan
关键词
Foulage test; Inertial measurement unit; Micro-electromechanical system; Modified fukuda stepping test; Multivariable regression analysis; Sensing technologies; Six-axis motion sensor; ACCELEROMETRY; ORIENTATION; BALANCE; GAIT; EYE;
D O I
10.1016/j.heliyon.2023.e15018
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Currently, vestibular rehabilitation approaches used to monitor body position and movement during rehabilitation training require specialized equipment or rely on clinician observation. Thus, a simpler position-sensing approach that can be used to monitor movement during vestibular rehabilitation is required. This study used wearable motion sensors with built-in ac-celerometers and gyrometers to assess movement in adults. We explored stepping patterns in adults using this motion-sensing system. Six healthy adults (men, age 27.3 +/- 5.8 years) under-went a modified Fukuda stepping test (Foulage test [FT]) while wearing a six-axis motion sensor (accelerometer: X-axis, Y-axis, Z-axis; gyrometer: X-axis, Y-axis, Z-axis) positioned at the head, thorax, and lumbar spine. For motion sensor parameters, we calculated the root mean square (RMS), autocorrelation coefficient (AC), power spectrum (PS) of the AC, and Euler angles from the six-axis motion sensor. For the FT parameters, the FT value, step variance, and theta values were calculated. Data were analyzed, and multivariable regression analysis was performed using the FT value, step variance, and theta value as the dependent variables to investigate their influence on dynamic equilibrium. The explanatory variables included the motion sensor parameters, RMS, AC, and PS. Our results suggested that almost no head and lumbar spine movement occurred while stepping with eyes open. Contrastingly, the head and lumbar spine swayed with eyes closed. This accelerometric and gyroscopic device is easy to use, does not require specialized equipment, and can be used to analyze performance in the modified Fukuda stepping test in clinical practice. Inertial sensors have many advantages over other sensing technologies.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A Portable Inertial Sensing-based Spinal Motion Measurement System for Low Back Pain Assessment
    Lee, Jung Keun
    Desmoulin, Geoffrey T.
    Khan, Aslam H.
    Park, Edward J.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4737 - 4740
  • [22] Improved Ergonomic Risk Factor Assessment Using OpenSim and Inertial Measurement Units
    Mortensen, Jonathan
    Trkov, Mitja
    Merryweather, Andrew
    2018 IEEE/ACM INTERNATIONAL CONFERECE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2018, : 27 - 28
  • [23] Center of Mass Estimation for Impaired Gait Assessment Using Inertial Measurement Units
    Labrozzi, Gabrielle C.
    Warner, Holly
    Makowski, Nathaniel S.
    Audu, Musa L.
    Triolo, Ronald J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 12 - 22
  • [24] ASSESSMENT OF LUMBAR SPINAL MOBILITY USING INERTIAL MEASUREMENT UNITS IN AXIAL SPONDYLOARTHRITIS
    Franco, L.
    Ward, W.
    Sengupta, R.
    Cazzola, D.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2018, 36 (04) : 756 - 756
  • [25] Cervical Coupling Motion Characteristics in Healthy People Using a Wireless Inertial Measurement Unit
    Kim, Hyunho
    Shin, Sang-Hoon
    Kim, Jeong-Kyun
    Park, Young-Jae
    Oh, Hwan-Sup
    Park, Young-Bae
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2013, 2013
  • [26] The feasibility of shoulder motion tracking during activities of daily living using inertial measurement units
    Kirking, Bryan
    El-Gohary, Mahmoud
    Kwon, Young
    GAIT & POSTURE, 2016, 49 : 47 - 53
  • [27] Motion artefact removal in electroencephalography and electrocardiography by using multichannel inertial measurement units and adaptive filtering
    Beach, Christopher
    Li, Mingjie
    Balaban, Ertan
    Casson, Alexander J.
    HEALTHCARE TECHNOLOGY LETTERS, 2021, 8 (05) : 128 - 138
  • [28] Reliability and Validity of Inertial Sensor Assisted Reaction Time Measurement Tools among Healthy Young Adults
    Harper, Brent
    Shiraishi, Michael
    Soangra, Rahul
    SENSORS, 2022, 22 (21)
  • [29] Walking assessment in the phase space by using Ultra-miniaturized Inertial Measurement Units
    Sessa, S.
    Saito, K.
    Zecca, M.
    Bartolomeo, L.
    Lin, Z.
    Cosentino, S.
    Ishii, H.
    Ikai, T.
    Takanishi, A.
    2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2013, : 902 - 907
  • [30] Inertial measurement unit-based motion capture to replace camera-based systems for assessing gait in healthy young adults: Proceed with caution
    Rekant J.
    Rothenberger S.
    Chambers A.
    Measurement: Sensors, 2022, 23