Modified Fukuda stepping motion assessment of young healthy adults using portable inertial measurement units

被引:2
|
作者
Miwa, Toru [1 ,2 ]
Yasuda, Tomohisa [3 ]
Kouga, Teppei [1 ]
Sunami, Kishiko [1 ]
机构
[1] Osaka Metropolitan Univ, Dept Otolaryngol Head & Neck Surg, 1-4-3 Asahi-machi, Abeno-ku, Osaka 5458585, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Otolaryngol Head & Neck Surg, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 6068507, Japan
[3] Yasuda ENT Clin, 1-1-1 TakarOachi, Katsusika-ku, Tokyo 1240005, Japan
关键词
Foulage test; Inertial measurement unit; Micro-electromechanical system; Modified fukuda stepping test; Multivariable regression analysis; Sensing technologies; Six-axis motion sensor; ACCELEROMETRY; ORIENTATION; BALANCE; GAIT; EYE;
D O I
10.1016/j.heliyon.2023.e15018
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Currently, vestibular rehabilitation approaches used to monitor body position and movement during rehabilitation training require specialized equipment or rely on clinician observation. Thus, a simpler position-sensing approach that can be used to monitor movement during vestibular rehabilitation is required. This study used wearable motion sensors with built-in ac-celerometers and gyrometers to assess movement in adults. We explored stepping patterns in adults using this motion-sensing system. Six healthy adults (men, age 27.3 +/- 5.8 years) under-went a modified Fukuda stepping test (Foulage test [FT]) while wearing a six-axis motion sensor (accelerometer: X-axis, Y-axis, Z-axis; gyrometer: X-axis, Y-axis, Z-axis) positioned at the head, thorax, and lumbar spine. For motion sensor parameters, we calculated the root mean square (RMS), autocorrelation coefficient (AC), power spectrum (PS) of the AC, and Euler angles from the six-axis motion sensor. For the FT parameters, the FT value, step variance, and theta values were calculated. Data were analyzed, and multivariable regression analysis was performed using the FT value, step variance, and theta value as the dependent variables to investigate their influence on dynamic equilibrium. The explanatory variables included the motion sensor parameters, RMS, AC, and PS. Our results suggested that almost no head and lumbar spine movement occurred while stepping with eyes open. Contrastingly, the head and lumbar spine swayed with eyes closed. This accelerometric and gyroscopic device is easy to use, does not require specialized equipment, and can be used to analyze performance in the modified Fukuda stepping test in clinical practice. Inertial sensors have many advantages over other sensing technologies.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The Fukuda Stepping Test Is Influenced by a Concurrent Cognitive Task and Step Height in Healthy Young Adults: A Descriptive Study
    Grostern, Jessica
    Lajoie, Yves
    Paquet, Nicole
    PHYSIOTHERAPY CANADA, 2021, 73 (04) : 322 - 328
  • [2] Assessment of walking quality by using Inertial Measurement Units
    Saito, K.
    Zecca, M.
    Sessa, S.
    Lin, Z.
    Bartolomeo, L.
    Cosentino, S.
    Petersen, K.
    Ishii, H.
    Ikai, T.
    Takanishi, A.
    2012 FIRST INTERNATIONAL CONFERENCE ON INNOVATIVE ENGINEERING SYSTEMS (ICIES), 2012, : 13 - 18
  • [3] Assessment of varus thrust using inertial measurement units
    Murro, Millissia A.
    Mihy, Julien A.
    Wagatsuma, Mayumi
    Hafer, Jocelyn F.
    CLINICAL BIOMECHANICS, 2025, 122
  • [4] Assessment of postural stability using inertial measurement unit on inclined surfaces in healthy adults
    Frames, Chris
    Soangra, Rahul
    Lockhart, Thurmon E.
    Biomedical Sciences Instrumentation, 2013, 49 : 234 - 242
  • [5] MEASURING GAIT KINEMATICS AND SELF SELECTED WALKING SPEED IN HEALTHY ADULTS USING INERTIAL MEASUREMENT UNITS
    Hodgins, D.
    OSTEOARTHRITIS AND CARTILAGE, 2018, 26 : S383 - S383
  • [6] Gait Characteristics Based on Shoe-Type Inertial Measurement Units in Healthy Young Adults during Treadmill Walking
    Lee, Myeounggon
    Youm, Changhong
    Noh, Byungjoo
    Park, Hwayoung
    SENSORS, 2020, 20 (07)
  • [7] Tracking limbs motion using a wireless network of inertial measurement units
    Buonocunto, Pasquale
    Marinoni, Mauro
    2014 9TH IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL EMBEDDED SYSTEMS (SIES), 2014,
  • [8] Gait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults
    Rantalainen, Timo
    Karavirta, Laura
    Pirkola, Henrikki
    Rantanen, Taina
    Linnamo, Vesa
    SENSORS, 2020, 20 (10)
  • [9] Quantification of the development of trunk control in healthy infants using inertial measurement units
    Blok, Janneke
    Poggensee, Katherine L.
    Lemus, Daniel
    Kok, Manon
    Pangalila, Robert F.
    Vallery, Heike
    Deferme, Jolien
    Toussaint-Duyster, Leontien C. C.
    Horemans, Herwin
    2022 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2022,
  • [10] Validity and Reliability of Inertial Measurement Units in Active Range of Motion Assessment in the Hip Joint
    Stolowski, Lukasz
    Niedziela, Maciej
    Lubiatowski, Bartlomiej
    Lubiatowski, Przemyslaw
    Piontek, Tomasz
    SENSORS, 2023, 23 (21)