Neural network guided sinogram-domain iterative algorithm for artifact reduction

被引:1
|
作者
Zeng, Gengsheng L. [1 ,2 ,3 ]
机构
[1] Utah Valley Univ, Dept Comp Sci, Salt Lake City, UT USA
[2] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USA
[3] Utah Valley Univ, Dept Comp Sci, 800 West Univ Pkwy,Mail Stop 129, Orem, UT 84058 USA
关键词
artifacts; computed tomography; image reconstruction; iterative algorithms; neural network; CT;
D O I
10.1002/mp.16546
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundArtifact reduction or removal is a challenging task when the artifact creation physics are not well modeled mathematically. One of such situations is metal artifacts in x-ray CT when the metallic material is unknown, and the x-ray spectrum is wide. PurposeA neural network is used to act as the objective function for iterative artifact reduction when the artifact model is unknown. MethodsA hypothetical unpredictable projection data distortion model is used to illustrate the proposed approach. The model is unpredictable, because it is controlled by a random variable. A convolutional neural network is trained to recognize the artifacts. The trained network is then used to compute the objective function for an iterative algorithm, which tries to reduce the artifacts in a computed tomography (CT) task. The objective function is evaluated in the image domain. The iterative algorithm for artifact reduction is in the projection domain. A gradient descent algorithm is used for the objective function optimization. The associated gradient is calculated with the chain rule. ResultsThe learning curves illustrate the decreasing treads of the objective function as the number of iterations increases. The images after the iterative treatment show the reduction of artifacts. A quantitative metric, the Sum Square Difference (SSD), also indicates the effectiveness of the proposed method. ConclusionThe methodology of using a neural network as an objective function has potential value for situations where a human developed model is difficult to describe the underlying physics. Real-world applications are expected to be benefit from this methodology.
引用
收藏
页码:5410 / 5420
页数:11
相关论文
共 50 条
  • [1] ICA-based noise reduction for PET sinogram-domain images
    Han, Xian-Hua
    Chen, Yen-Wei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1655 - +
  • [2] A CT metal artifact reduction algorithm based on sinogram surgery
    Jeon, Soomin
    Lee, Chang-Ock
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (03) : 413 - 434
  • [3] Metal artifact reduction algorithm using directional interpolation by sinogram decomposed derivatives
    Nam, Haewon
    Baek, Jongduk
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [4] REDUCTION OF BLADDER ARTIFACT IN SPECT BY AN ITERATIVE RECONSTRUCTION ALGORITHM
    REULAND, P
    KAISER, W
    MULLERSCHAUENBURG, W
    FEINE, U
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1991, 22 (01): : 23 - 24
  • [5] Ordered Subsets Acceleration of Iterative Algorithm for Variance Reduction on Compressed Sinogram Random Coincidences
    Panin, Vladimir Y.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2986 - 2990
  • [6] IRDNet: Iterative Relation-Based Dual-Domain Network via Metal Artifact Feature Guidance for CT Metal Artifact Reduction
    Wang, Huamin
    Yang, Shuo
    Bai, Xiao
    Wang, Zhe
    Wu, Jiayi
    Lv, Yang
    Cao, Guohua
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (08) : 959 - 972
  • [7] DuDoNet: Dual Domain Network for CT Metal Artifact Reduction
    Lin, Wei-An
    Liao, Haofu
    Peng, Cheng
    Sun, Xiaohang
    Zhang, Jingdan
    Luo, Jiebo
    Chellappa, Rama
    Zhou, Shaohua Kevin
    2019 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2019), 2019, : 10504 - 10513
  • [8] Using a deep neural network for four-dimensional CT artifact reduction in image-guided radiotherapy
    Mori, Shinichiro
    Hirai, Ryusuke
    Sakata, Yukinobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 67 - 75
  • [9] Fast iterative algorithm for metal artifact reduction in X-ray CT
    Wang, G
    Frei, T
    Vannier, MW
    ACADEMIC RADIOLOGY, 2000, 7 (08) : 607 - 614
  • [10] The λ-MLEM algorithm:: An iterative reconstruction technique for metal artifact reduction in CT images
    Oehler, May
    Buzug, Thorsten M.
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 42 - +