Role of Cerebral Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement: An Updated Meta-Analysis

被引:3
|
作者
Kaur, Arpanjeet [2 ]
Dhaliwal, Arshdeep S. [3 ]
Sohal, Sumit [4 ]
Gwon, Yeongjin [5 ]
Gupta, Soumya [2 ]
Bhatia, Kirtipal [6 ]
Dominguez, Abel Casso [6 ]
Basman, Craig [7 ]
Tamis-Holland, Jacqueline [1 ,8 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Main Campus,9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Icahn Sch Med Mt Sinai Morningside West New York, Dept Med, New York, NY USA
[3] Icahn Sch Med Mt Sinai, Populat Hlth Sci & Policy, New York, NY USA
[4] Newark Beth Israel Med Ctr Newark, Div Cardiovasc Med, Newark, NJ USA
[5] Univ Nebraska Med Ctr, Dept Biostat, Omaha, NE USA
[6] Icahn Sch Med Mt Sinai Morningside New York, Div Cardiol, New York, NY USA
[7] Lenox Hill Hosp, Div Cardiol, New York, NY USA
[8] Cleveland Clin, Dept Cardiovasc Med, Main Campus, Cleveland, OH USA
来源
关键词
cerebral embolic protection devices; stroke; transcatheter aortic valve replacement; RANDOMIZED EVALUATION; IMPLANTATION; STENOSIS; LESIONS;
D O I
10.1161/JAHA.123.030587
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cerebral embolic protection devices (CEPD) capture embolic material in an attempt to reduce ischemic brain injury during transcatheter aortic valve replacement. Prior reports have indicated mixed results regarding the benefits of these devices. With new data emerging, we performed an updated meta-analysis examining the effect of CEPD during transcatheter aortic valve replacement on various clinical, neurological, and safety parameters.Methods and Results A comprehensive review of electronic databases was performed comparing CEPD and no-CEPD in transcatheter aortic valve replacement. Primary clinical outcome was all-cause stroke. Secondary clinical outcomes were disabling stroke and all-cause mortality. Neurological outcomes included worsening of the National Institutes of Health Stroke Scale score, Montreal Cognitive Assessment score from baseline at discharge, presence of new ischemic lesions, and total lesion volume on neuroimaging. Safety outcomes included major or minor vascular complications and stage 2 or 3 acute kidney injury. Seven randomized controlled trials with 4016 patients met the inclusion criteria. There was no statistically significant difference in the primary clinical outcome of all-cause stroke; secondary clinical outcomes of disabling stroke, all-cause mortality, neurological outcomes of National Institutes of Health Stroke Scale score worsening, Montreal Cognitive Assessment worsening, presence of new ischemic lesions, or total lesion volume on diffusion-weighted magnetic resonance imaging between CEPD versus control groups. There was no statistically significant difference in major or minor vascular complications or stage 2 or 3 acute kidney injury between the groups.Conclusions The use of CEPD in transcatheter aortic valve replacement was not associated with a statistically significant reduction in the risk of clinical, neurological, and safety outcomes.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Cerebral Embolic Protection in Transcatheter Aortic Valve Replacement
    Iskander, Mina
    Jamil, Yasser
    Forrest, John K.
    Madhavan, Mahesh V.
    Makkar, Raj
    Leon, Martin B.
    Lansky, Alexandra
    Ahmad, Yousif
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2023, 7 (04):
  • [22] A Meta-Analysis of Embolic Protection Devices in the Prevention of Cerebrovascular Events after Transcatheter Aortic Valve Replacement
    Ansari, Mohammad M.
    Cardoso, Rhanderson N.
    Garcia, Daniel C.
    Spaziano, Marco
    de Marchena, Eduardo
    Brinster, Derek
    Scheinerman, S. Jacob
    Martucci, Giuseppe
    Piazza, Nicolo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B309 - B309
  • [23] Cerebral Embolic Protection Devices: Are There Any Indications in Transcatheter Aortic Valve Replacement?
    Sayah, Neila
    Skalidis, Ioannis
    Mesnier, Jules
    Neylon, Antoinette
    Akodad, Mariama
    Asgar, Anita
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (18)
  • [24] Neurologic Outcomes with Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Giustino, Gennaro
    Mehran, Roxana
    Veltkamp, Roland
    Faggioni, Michela
    Danias, George
    Baber, Usman
    Dangas, George
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B266 - B267
  • [25] Neurologic Outcomes With Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Giustino, Gennaro
    Mehran, Roxana
    Veltkamp, Roland
    Faggioni, Michela
    Danias, George
    Baber, Usman
    Dangas, George
    CIRCULATION, 2016, 134
  • [26] Neurological Outcomes With Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Giustino, Gennaro
    Mehran, Roxana
    Veltkamp, Roland
    Faggioni, Michela
    Baber, Usman
    Dangas, George D.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (20) : 2124 - 2133
  • [27] Neurological outcomes of transcatheter aortic valve implantation with or without cerebral embolic protection devices: A meta-analysis
    Perez-Camargo, Daniel
    Travieso, Alejandro
    Carnero-Alcazar, Manuel
    Taramasso, Maurizio
    Cobiella-Carnicer, Javier
    Maroto-Castellanos, Luis C.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (09):
  • [28] Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Implantation Systematic Review and Meta-Analysis
    Bagur, Rodrigo
    Solo, Karla
    Alghofaili, Saleh
    Nombela-Franco, Luis
    Kwok, Chun Shing
    Hayman, Samual
    Siemieniuk, Reed A.
    Foroutan, Farid
    Spencer, Frederick A.
    Vandvik, Per O.
    Schaeufele, Tim G.
    Mamas, Mamas A.
    STROKE, 2017, 48 (05) : 1306 - +
  • [29] Outcomes of Cerebral Embolic Protection for Bicuspid Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement
    Zhang, Jiajun
    Li, Xiaoxing
    Tian, Rui
    Zong, Mengzhi
    Gu, Xinghua
    Xu, Feng
    Chen, Yuguo
    Li, Chuanbao
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (12):
  • [30] Clinical Outcomes of the Sentinel Cerebral Protection System in Patients Undergoing Transcatheter Aortic Valve Replacement: A Meta-Analysis
    Ndunda, Paul
    Vindhyal, Mohinder
    Srinivasan, Sachin
    Muutu, Tabitha
    Hammami, Sumaya
    Fanari, Zaher
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B236 - B236