Ultrasound measurement of optic nerve sheath diameter in a healthy adult Colombian population

被引:6
|
作者
Trocha, Guillermo [1 ]
Bonilla, Andres [1 ]
Romero, Camilo [1 ]
Palacios, Jonathan [2 ]
Molano-Gonzalez, Nicolas [3 ]
机构
[1] Fdn Cardioinfantil, Dept Neurol, Inst Cardiol, Bogota, Colombia
[2] Fdn Cardioinfantil, Dept Crit Care Med, Inst Cardiol, Bogota, Colombia
[3] Univ Rosario, Sch Med & Hlth Sci, Clin Res Grp, Bogota, Colombia
关键词
Optic nerve sheath diameter; Ultrasonography; Healthy Adults; Latin America;
D O I
10.1186/s12883-023-03062-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundMeasurement of the optic nerve sheath diameter (ONSD) provides a rapid, safe, and easy method for detecting increased intracranial pressure (ICP). However, the normal mean and upper limit values may vary according to sex, age, ethnicity, and ultrasound technique.AimWe aimed to obtain the mean ONSD in a healthy Colombian adult population and to correlate it with demographic and anthropometric measures.MethodsIn a prospective study using a 10-13 MHz linear ultrasound probe, eye transverse diameter (ETD) and ONSD in the transverse (ONSD-TP) and sagittal planes (ONSD-SP) were measured in healthy adult volunteers in Bogota, Colombia.ResultsA total of 100 healthy subjects were included, with a mean age of 26,7 +/- 8,3 years and 62 women. The mean ETD, ONSD-TP and ONSD-SP was 23.11 mm (95% confidence interval (CI): 22.90 mm-23.32 mm), 3.96 mm (95% CI: 3.85 mm-4.07 mm) and 4.0 mm (95% CI: 3.90 mm-4.11 mm), respectively. The ONSD in both planes ranged from 2.35 mm to 5.20 mm. There was a significant correlation between ONSD-SP and ONSD-TP (p < 0.0001) but no correlation between the ocular measures and demographic or anthropometric variables (p > 0.05). The intraclass correlation between the eyes was statistically significant.ConclusionOur study shows that ultrasound-measured ONSD in healthy adults in Colombia is similar to that found worldwide. An ONSD of 5.5 mm may be considered the upper limit for healthy adults in Colombia. ONSD can be measured in either plane; there is a good correlation between the two eyes; and ONSD is not modified by demographic or anthropometric characteristics.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Measurement of the Optic Nerve Sheath Diameter with Magnetic Resonance Imaging and Its Association with Eyeball Diameter in Healthy Adults
    Kim, Dong Hwan
    Jun, Jin-Sun
    Kim, Ryul
    JOURNAL OF CLINICAL NEUROLOGY, 2018, 14 (03): : 345 - 350
  • [42] Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study
    Yang, Ziyue
    Qin, Cuihong
    Zhang, Shuguang
    Liu, Shaohua
    Sun, Tongwen
    CRITICAL CARE, 2020, 24 (01):
  • [43] Ultrasound measurement of optic nerve sheath diameter pre- and post-lumbar puncture
    Christopher K. Schott
    Mohammad I. Hirzallah
    Rock Heyman
    Daniel N. Lesky
    Emily B. Brant
    Clifton W. Callaway
    The Ultrasound Journal, 12
  • [44] Advancements in Ultrasound Techniques for Evaluating Intracranial Pressure Through Optic Nerve Sheath Diameter Measurement
    Fan, Wei-Ze
    Jiang, Jun-Rong
    Zang, Hui-Ling
    Shen, Xiao-Hui
    Cheng, Hui
    Yang, Wen-Juan
    Wang, Hui
    Jing, Li-Xing
    WORLD NEUROSURGERY, 2024, 189 : 285 - 290
  • [45] Optic nerve sheath diameter ultrasound measurement to evaluate cerebral edema in children with diabetic ketoacidosis
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2019, 32 (11): : 1205 - 1206
  • [46] Detection of raised intracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children
    Beare, Nicholas A. V.
    Kampondeni, Sam
    Glover, Simon J.
    Molyneux, Elizabeth
    Taylor, Terrie E.
    Harding, Simon P.
    Molyneux, Malcolm E.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2008, 13 (11) : 1400 - 1404
  • [47] A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement
    Zeiler F.A.
    Ziesmann M.T.
    Goeres P.
    Unger B.
    Park J.
    Karakitsos D.
    Blaivas M.
    Vergis A.
    Gillman L.M.
    Critical Ultrasound Journal, 2016, 8 (1)
  • [48] Ultrasound measurement of optic nerve sheath diameter pre- and post-lumbar puncture
    Schott, Christopher K.
    Hirzallah, Mohammad, I
    Heyman, Rock
    Lesky, Daniel N.
    Brant, Emily B.
    Callaway, Clifton W.
    ULTRASOUND JOURNAL, 2020, 12 (01):
  • [49] Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure
    Major, Robert
    Girling, Simon
    Boyle, Adrian
    EMERGENCY MEDICINE JOURNAL, 2011, 28 (08) : 679 - 681
  • [50] Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study
    Ziyue Yang
    Cuihong Qin
    Shuguang Zhang
    Shaohua Liu
    Tongwen Sun
    Critical Care, 24