Ultrasound measurement of optic nerve sheath diameter in a healthy adult Colombian population

被引:6
|
作者
Trocha, Guillermo [1 ]
Bonilla, Andres [1 ]
Romero, Camilo [1 ]
Palacios, Jonathan [2 ]
Molano-Gonzalez, Nicolas [3 ]
机构
[1] Fdn Cardioinfantil, Dept Neurol, Inst Cardiol, Bogota, Colombia
[2] Fdn Cardioinfantil, Dept Crit Care Med, Inst Cardiol, Bogota, Colombia
[3] Univ Rosario, Sch Med & Hlth Sci, Clin Res Grp, Bogota, Colombia
关键词
Optic nerve sheath diameter; Ultrasonography; Healthy Adults; Latin America;
D O I
10.1186/s12883-023-03062-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundMeasurement of the optic nerve sheath diameter (ONSD) provides a rapid, safe, and easy method for detecting increased intracranial pressure (ICP). However, the normal mean and upper limit values may vary according to sex, age, ethnicity, and ultrasound technique.AimWe aimed to obtain the mean ONSD in a healthy Colombian adult population and to correlate it with demographic and anthropometric measures.MethodsIn a prospective study using a 10-13 MHz linear ultrasound probe, eye transverse diameter (ETD) and ONSD in the transverse (ONSD-TP) and sagittal planes (ONSD-SP) were measured in healthy adult volunteers in Bogota, Colombia.ResultsA total of 100 healthy subjects were included, with a mean age of 26,7 +/- 8,3 years and 62 women. The mean ETD, ONSD-TP and ONSD-SP was 23.11 mm (95% confidence interval (CI): 22.90 mm-23.32 mm), 3.96 mm (95% CI: 3.85 mm-4.07 mm) and 4.0 mm (95% CI: 3.90 mm-4.11 mm), respectively. The ONSD in both planes ranged from 2.35 mm to 5.20 mm. There was a significant correlation between ONSD-SP and ONSD-TP (p < 0.0001) but no correlation between the ocular measures and demographic or anthropometric variables (p > 0.05). The intraclass correlation between the eyes was statistically significant.ConclusionOur study shows that ultrasound-measured ONSD in healthy adults in Colombia is similar to that found worldwide. An ONSD of 5.5 mm may be considered the upper limit for healthy adults in Colombia. ONSD can be measured in either plane; there is a good correlation between the two eyes; and ONSD is not modified by demographic or anthropometric characteristics.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Ultrasonography of Optic Nerve Sheath Diameter in Healthy Volunteers
    Remon, Ariel Sosa
    Rodriguez, Wilfredo Boch
    Arias, Dasha Maria Garcia
    Chavez, Carmen Esther Remon
    Alvarez, Ana Esperanza Jerez
    Naranjo, Arian Jesus Cuba
    FINLAY, 2024, 14 (01): : 97 - 103
  • [22] ULTRASOUND APPRAISAL OF OPTIC NERVE SHEATH DIAMETER IN CERVICAL COLLAR APPLIED HEALTHY VOLUNTEERS
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nichola
    JOURNAL OF EMERGENCY MEDICINE, 2020, 58 (01): : 125 - 126
  • [23] Ultrasound Nomograms of the Fetal Optic Nerve Sheath Diameter
    Haratz, Karina Krajden
    Melcer, Yaakov
    Leibovitz, Zvi
    Feit, Hagit
    Lerman-Sagie, Tally
    Lev, Dorit
    Ginath, Shimon
    Gindes, Liat
    Moron, Antonio Fernandes
    Malinger, Gustavo
    ULTRASCHALL IN DER MEDIZIN, 2019, 40 (04): : 476 - 480
  • [24] Response to a letter to the editor "Ultrasound assessment of optic nerve sheath diameter in healthy volunteers"
    Gillman, Lawrence M.
    Zeiler, Frederick A.
    Unger, Bertram
    Karakitsos, Dimitrios
    JOURNAL OF CRITICAL CARE, 2017, 40 : 280 - 280
  • [25] Optic nerve sheath diameter ultrasound: Yes, No, and Maybe?
    Fischer, Ernest A.
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2021, 2 (04)
  • [26] Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging
    Shirodkar, Chetan G.
    Munta, Kartik
    Rao, S. Manimala
    Mahesh, M. Uma
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 19 (08) : 466 - 470
  • [27] ACCURACY OF OPTIC NERVE SHEATH DIAMETER MEASUREMENT BY EMERGENCY PHYSICIANS USING BEDSIDE ULTRASOUND
    Hassen, Getaw Worku
    Bruck, Isaac
    Donahue, Joseph
    Mason, Benjamin
    Sweeney, Brett
    Saab, Weafue
    Weedon, Jeremy
    Patel, Neal
    Perry, Kenneth
    Matari, Hussein
    Jaiswal, Rajnish
    Kalantari, Hossein
    JOURNAL OF EMERGENCY MEDICINE, 2015, 48 (04): : 450 - 457
  • [28] Ultrasound measurement of the optic nerve sheath diameter in traumatic brain injury: a narrative review
    Natile, M.
    Simonet, O.
    Vallot, F.
    De Kock, M.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 (04) : 151 - 168
  • [29] Optic nerve sheath diameter measurement by ultrasound after moderate traumatic brain injury
    Graziano, Mario
    Biondino, Danilo
    Fioretto, Isabella
    Marino, Andrea Valerio
    CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, 2023, 10 (02): : 249 - 250
  • [30] Sonographic measurement of the optic nerve sheath diameter at height
    Kunze, Georg
    FLUGMEDIZIN TROPENMEDIZIN REISEMEDIZIN, 2023, 30 (06): : 269 - 270