Comparative Analysis of Nipple Reconstruction Five vs. C-V

被引:0
|
作者
Ferraro, Giuseppe Andrea [1 ]
Gesuet, Francesco Paolo [1 ]
Molle, Marcello [1 ,2 ]
Cosenza, Vincenzo [1 ]
Filosa, Francesco Giuseppe [1 ]
Pelella, Tommaso [1 ]
Nicoletti, Giovanni Francesco [1 ]
机构
[1] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Dent Specialties, Plast & Reconstruct Surg Unit, Naples, Italy
[2] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Dent Specialties, Plast & Reconstruct Surg Unit, Piazza Luigi Miraglia 2, I-80138 Naples, Italy
来源
JPRAS OPEN | 2024年 / 39卷
关键词
5; Flap; C -V Flap; NAC reconstruction; Case-control nipple reconstruction; SPARING MASTECTOMY; FLAP; TIME;
D O I
10.1016/j.jpra.2023.11.014
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Nipple-areola complex reconstruction represents the final phase in the comprehensive post-mastectomy treatment regimen. Despite the diversity of approaches available, there is currently no universally accepted benchmark technique for this critical aspect of breast reconstruction. In this study, we conducted a comparative assessment of two prominent techniques, the five Flap and C-V Flap.Materials and Methods: Between November 2016 and April 2023, we recruited 100 female patients who had undergone unilateral post-oncological mastectomy and divided them into two groups: Group A comprising 50 patients who underwent the 5-Flap technique, whereas Group B comprising the remaining 50 underwent the C-V Flap technique. Over a 6-month observation period, we assessed nipple projection loss and evaluated overall satisfaction through self-reporting by patients and independent assessments by a medical observer.Results: In our study, none of the reconstructed nipples in Group A (5 Flap) experienced either total or partial necrosis, contrasting with Group B (C-V Flap) which encountered a 10% incidence of partial necrosis and 4% incidence of total necrosis. Furthermore, the average nipple projection loss in Group B was substantial, measuring a 30% reduction from the initial projection at the 1-year mark, whereas Group A demonstrated a significantly lower 13% reduction. Notably, despite these variations in outcomes, both groups reported an equal and high level of satisfaction, with patients and external observers providing an average satisfaction score of 8.0 and 9.0, respectively.Conclusion: The five-flap technique represents a safe and effective approach for patients undergoing nipple reconstruction.(c) 2023 The Author(s). Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [41] Comparative analysis of propeller flaps vs. modified perforator-based flaps in foot and ankle reconstruction
    Rajkumar R
    Harish Kumar Sharma
    Suvashis Dash
    Vaddi Suman Babu
    European Journal of Plastic Surgery, 2021, 44 : 243 - 248
  • [42] Comparative analysis of propeller flaps vs. modified perforator-based flaps in foot and ankle reconstruction
    Rajkumar, R.
    Sharma, Harish Kumar
    Dash, Suvashis
    Babu, Vaddi Suman
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 2021, 44 (02) : 243 - 248
  • [43] A Comparative Analysis of Outcomes of Free Nipple Areolar Grafting in Autologous Breast Reconstruction
    Egan, Katie G.
    Lai, Eric
    Holding, Julie
    Butterworth, James
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2021, 37 (05) : 458 - 464
  • [44] AIR AS AN ADJUSTABLE INSULATOR FOR C-V AND G-V ANALYSIS OF SEMICONDUCTOR SURFACES
    MORELAND, J
    DRUCKER, J
    HANSMA, PK
    KOTTHAUS, JP
    ADAMS, A
    KVAAS, R
    APPLIED PHYSICS LETTERS, 1984, 45 (01) : 104 - 106
  • [45] Letter in response to Macdonald C, Nakhdjevani A, Shah A. The "Swiss-Roll" flap: A modified C-V flap for nipple reconstruction. The Breast 20 (2011) 475-477
    Matthews, Edward
    Ahmed, Foiz
    Breeze, John
    Heppell, Simon
    BREAST, 2012, 21 (01): : 109 - 109
  • [46] PULSE SCANNING C-V TECHNIQUE FOR THE ANALYSIS OF CARRIER GENERATION IN SI
    KAWAZU, S
    MATSUKAWA, T
    NAKATA, H
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1981, 128 (03) : C100 - C101
  • [47] C-V ANALYSIS OF THE SCHOTTKY-BARRIER IN UNDOPED SEMIINSULATING GAAS
    DUBECKY, F
    DARMO, J
    BETKO, J
    MOZOLOVA, Z
    PELFER, PG
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1994, 9 (09) : 1654 - 1658
  • [48] C-V ANALYSIS OF SCHOTTKY BARRIERS IN PRESENCE OF A SERIES BULK RESISTANCE
    SHAW, RF
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (10): : 1118 - 1118
  • [49] STATISTICAL TECHNIQUES VS. MACHINE LEARNING MODELS: A COMPARATIVE ANALYSIS FOR EXCHANGE RATE FORECASTING IN FRAGILE FIVE COUNTRIES
    Bakir, Muhammed Rasid
    Bakirtas, Ibrahim
    Olmez, Emre
    ECONOMIC COMPUTATION AND ECONOMIC CYBERNETICS STUDIES AND RESEARCH, 2023, 57 (03): : 295 - 312
  • [50] Comparative Analysis of Molecular BeadChip Assays and Serology for C c E and e, and VS and V Antigens
    Ishtiaq, G.
    Song, Y.
    Hailemariam, T.
    Enriquez, E.
    Naik, U.
    Garg, D.
    TRANSFUSION, 2013, 53 : 172A - 172A