Comparative Analysis of Nipple Reconstruction Five vs. C-V

被引:0
|
作者
Ferraro, Giuseppe Andrea [1 ]
Gesuet, Francesco Paolo [1 ]
Molle, Marcello [1 ,2 ]
Cosenza, Vincenzo [1 ]
Filosa, Francesco Giuseppe [1 ]
Pelella, Tommaso [1 ]
Nicoletti, Giovanni Francesco [1 ]
机构
[1] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Dent Specialties, Plast & Reconstruct Surg Unit, Naples, Italy
[2] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Dent Specialties, Plast & Reconstruct Surg Unit, Piazza Luigi Miraglia 2, I-80138 Naples, Italy
来源
JPRAS OPEN | 2024年 / 39卷
关键词
5; Flap; C -V Flap; NAC reconstruction; Case-control nipple reconstruction; SPARING MASTECTOMY; FLAP; TIME;
D O I
10.1016/j.jpra.2023.11.014
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Nipple-areola complex reconstruction represents the final phase in the comprehensive post-mastectomy treatment regimen. Despite the diversity of approaches available, there is currently no universally accepted benchmark technique for this critical aspect of breast reconstruction. In this study, we conducted a comparative assessment of two prominent techniques, the five Flap and C-V Flap.Materials and Methods: Between November 2016 and April 2023, we recruited 100 female patients who had undergone unilateral post-oncological mastectomy and divided them into two groups: Group A comprising 50 patients who underwent the 5-Flap technique, whereas Group B comprising the remaining 50 underwent the C-V Flap technique. Over a 6-month observation period, we assessed nipple projection loss and evaluated overall satisfaction through self-reporting by patients and independent assessments by a medical observer.Results: In our study, none of the reconstructed nipples in Group A (5 Flap) experienced either total or partial necrosis, contrasting with Group B (C-V Flap) which encountered a 10% incidence of partial necrosis and 4% incidence of total necrosis. Furthermore, the average nipple projection loss in Group B was substantial, measuring a 30% reduction from the initial projection at the 1-year mark, whereas Group A demonstrated a significantly lower 13% reduction. Notably, despite these variations in outcomes, both groups reported an equal and high level of satisfaction, with patients and external observers providing an average satisfaction score of 8.0 and 9.0, respectively.Conclusion: The five-flap technique represents a safe and effective approach for patients undergoing nipple reconstruction.(c) 2023 The Author(s). Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [31] Simultaneous abdominoplasty and umbilical reconstruction using a modified C-V flap technique
    Uraloglu, Muhammet
    Tekin, Fatih
    Orbay, Hakan
    Unlu, Ramazan Erkin
    Sensoz, Omer
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 117 (07) : 2525 - 2526
  • [32] Umbilical reconstruction using a modified inverted C-V flap with conjoint flaps
    Lee, Yoonho
    Lee, San Ha
    Woo, Kevin Volt
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2013, 47 (04) : 334 - 336
  • [33] Impulse C vs. VHDL for Accelerating Tomographic Reconstruction
    Xu, Jimmy
    Subramanian, Nikhil
    Alessio, Adam
    Hauck, Scott
    2010 18TH IEEE ANNUAL INTERNATIONAL SYMPOSIUM ON FIELD-PROGRAMMABLE CUSTOM COMPUTING MACHINES (FCCM 2010), 2010, : 171 - 174
  • [34] Analysis of C-V and I-V data of BST thin films
    Symetrix Corp, Colorado Springs, United States
    Integr Ferroelectr, 1 -4 pt 1 (133-140):
  • [35] Analysis of C-V and I-V data of BST thin films
    Joshi, V
    Dacruz, CP
    Cuchiaro, JD
    Araujo, CA
    Zuleeg, R
    INTEGRATED FERROELECTRICS, 1997, 14 (1-4) : 133 - 140
  • [36] ANALYSIS OF C-V DATA IN ACCUMULATION REGIME OF MIS STRUCTURES
    LEHOVEC, K
    LIN, ST
    SOLID-STATE ELECTRONICS, 1976, 19 (12) : 993 - 996
  • [37] Replacement of C-V monitoring with noncontact COS charge analysis
    Catmull, KB
    Cosway, RG
    Letherer, BA
    Horner, GS
    MATERIALS RELIABILITY IN MICROELECTRONICS VII, 1997, 473 : 167 - 172
  • [38] Comparative study of C-V and transconductance of a Si δ-doped GaAs FET structure
    Suzuki, Takamasa
    Katsuno, Motonari
    Goto, Hideo
    Sawaki, Nobuhiko
    Ito, Hiroshi
    Hara, Kunihiko
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1996, 35 (4 A): : 2008 - 2011
  • [39] Digital vs. analogue spectroscopy: a comparative analysis
    Ripamonti, G
    Pullia, A
    Geraci, A
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 666 - 669
  • [40] Capacitance reconstruction from measured C-V in high leakage, nitride/oxide MOS
    Choi, CH
    Wu, Y
    Goo, JS
    Yu, ZP
    Dutton, RW
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2000, 47 (10) : 1843 - 1850