A simple, ultrasensitive and cost-effective electrochemical sensor for the determination of ciprofloxacin in various types of samples

被引:42
|
作者
Adane, Wondimeneh Dubale [1 ]
Chandravanshi, Bhagwan Singh [1 ]
Tessema, Merid [1 ]
机构
[1] Addis Ababa Univ, Dept Chem, POB 1176, Addis Ababa, Ethiopia
关键词
Ciprofloxacin; Choline chloride; Carbon paste electrode; Square wave voltammetry; Electrochemical sensor; SPECTROPHOTOMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; BIOELECTROCHEMICAL SENSOR; GRAPHENE OXIDE; NANOPARTICLES; ELECTRODE; ANTIBIOTICS; FABRICATION; PLASMA; URINE;
D O I
10.1016/j.sbsr.2022.100547
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a simple, ultrasensitive, inexpensive, and environmentally friendly sensor was developed for the electrochemical determination of ciprofloxacin (CPRO) using a choline chloride-modified carbon paste electrode (ChCl/CPE). The electrochemical properties of ChCl/CPE were examined by square wave voltammetry (SWV). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), ultraviolet-visible (UV-Vis) spectroscopy, and Fourier transform infrared (FT-IR) spectrometry were used for electrochemical and morphological characterizations. The sensor exhibits excellent conductivity and superior electrocatalytic activity, within the linear range of 0.005-200 mu M, for the detection of CPRO in citrate buffer solution (CBS) at pH 5, with detection and quantification limits of 0.36 nM and 1.2 nM. The electroactive surface area of ChCl/CPE was calculated to be 0.123 cm3, which is four times higher than that of the bare CPE (0.037 cm2). The ChCl/CPE is not only simple, inexpensive and time-saving, but also has the lowest detection limit and widest linear range compared to the recently reported sensors for the determination of CPRO. The developed sensor also showed excellent reproducibility, repeatability, long-term stability, and exceptional selectivity against potentially interfering organic, inorganic, and antibiotic species. In addition, ChCl/CPE was successfully applied for the determination of ciprofloxacin in eye drops, river water, and egg samples with very good recoveries of 97-102% and relative standard deviations (RSD) of 0.27-3.85%. Therefore, the proposed electrochemical sensor is a potential candidate for the determination of ciprofloxacin in various matrices.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Low-cost paper-based electrochemical sensor for the detection of ciprofloxacin in honey and milk samples
    de Souza, Cassiano Cunha
    Alves, Guilherme Figueira
    Lisboa, Thalles Pedrosa
    Costa Matos, Maria Auxiliadora
    Matos, Renato Camargo
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 112
  • [42] A Simple, Efficient and Ultrasensitive Gold Nanourchin Based Electrochemical Sensor for the Determination of an Antimalarial Drug: Mefloquine
    Chiwunze, Tirivashe Elton
    Thapliyal, Neeta Bachheti
    Palakollu, Venkata Narayana
    Karpoormath, Rajshekhar
    ELECTROANALYSIS, 2017, 29 (09) : 2138 - 2146
  • [43] Development of a Simple, Fast, and Cost-Effective Nanobased Immunoassay Method for Detecting Norovirus in Food Samples
    Alhadrami, Hani A.
    Al-Amer, Saleh
    Aloraij, Yumna
    Alhamlan, Fatimah
    Chinnappan, Raja
    Abu-Salah, Khalid M.
    Almatrrouk, Shaihana
    Zourob, Mohammed M.
    ACS OMEGA, 2020, 5 (21): : 12162 - 12165
  • [44] A simple and cost-effective method for obtaining DNA from a wide range of animal wildlife samples
    Hoyos, Manuel
    Tusso, Sergio
    Ruiz Bedoya, Tatiana
    Manrique Gaviria, Angelica S.
    Bloor, Paul
    CONSERVATION GENETICS RESOURCES, 2017, 9 (04) : 513 - 521
  • [45] A simple and cost-effective method for obtaining DNA from a wide range of animal wildlife samples
    Manuel Hoyos
    Sergio Tusso
    Tatiana Ruiz Bedoya
    Angélica S. Manrique Gaviria
    Paul Bloor
    Conservation Genetics Resources, 2017, 9 : 513 - 521
  • [46] Fast, simple and cost-effective determination of thiopental in human plasma by a new HPLC technique
    Coppa, G
    Testa, R
    Gambini, AM
    Testa, I
    Tocchini, M
    Bonfigli, AR
    CLINICA CHIMICA ACTA, 2001, 305 (1-2) : 41 - 45
  • [47] Development of Cost-Effective Sensor for Simultaneous Determination of Nanoplastics Using Artificial Neural Network
    Fdhila, Alaeddine
    Jebril, Siwar
    Dridi, Cherif
    IEEE SENSORS JOURNAL, 2023, 23 (22) : 27038 - 27045
  • [48] Development of An Eco-Friendly and Cost-Effective Electrochemical Sensor for the Simultaneous Detection of Dopamine and Serotonin
    Moslah, Maroua
    Dridi, Cherif
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (06)
  • [49] Preparation and application of a simple electrochemical sensor for the determination of copper in some real and standard samples
    Mojtaba Nasiri-Majd
    Mohammad Ali Taher
    Hamid Fazelirad
    Ionics, 2016, 22 : 289 - 296
  • [50] Preparation and application of a simple electrochemical sensor for the determination of copper in some real and standard samples
    Nasiri-Majd, Mojtaba
    Taher, Mohammad Ali
    Fazelirad, Hamid
    IONICS, 2016, 22 (02) : 289 - 296