A simple, ultrasensitive and cost-effective electrochemical sensor for the determination of ciprofloxacin in various types of samples

被引:42
|
作者
Adane, Wondimeneh Dubale [1 ]
Chandravanshi, Bhagwan Singh [1 ]
Tessema, Merid [1 ]
机构
[1] Addis Ababa Univ, Dept Chem, POB 1176, Addis Ababa, Ethiopia
关键词
Ciprofloxacin; Choline chloride; Carbon paste electrode; Square wave voltammetry; Electrochemical sensor; SPECTROPHOTOMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; BIOELECTROCHEMICAL SENSOR; GRAPHENE OXIDE; NANOPARTICLES; ELECTRODE; ANTIBIOTICS; FABRICATION; PLASMA; URINE;
D O I
10.1016/j.sbsr.2022.100547
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a simple, ultrasensitive, inexpensive, and environmentally friendly sensor was developed for the electrochemical determination of ciprofloxacin (CPRO) using a choline chloride-modified carbon paste electrode (ChCl/CPE). The electrochemical properties of ChCl/CPE were examined by square wave voltammetry (SWV). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), ultraviolet-visible (UV-Vis) spectroscopy, and Fourier transform infrared (FT-IR) spectrometry were used for electrochemical and morphological characterizations. The sensor exhibits excellent conductivity and superior electrocatalytic activity, within the linear range of 0.005-200 mu M, for the detection of CPRO in citrate buffer solution (CBS) at pH 5, with detection and quantification limits of 0.36 nM and 1.2 nM. The electroactive surface area of ChCl/CPE was calculated to be 0.123 cm3, which is four times higher than that of the bare CPE (0.037 cm2). The ChCl/CPE is not only simple, inexpensive and time-saving, but also has the lowest detection limit and widest linear range compared to the recently reported sensors for the determination of CPRO. The developed sensor also showed excellent reproducibility, repeatability, long-term stability, and exceptional selectivity against potentially interfering organic, inorganic, and antibiotic species. In addition, ChCl/CPE was successfully applied for the determination of ciprofloxacin in eye drops, river water, and egg samples with very good recoveries of 97-102% and relative standard deviations (RSD) of 0.27-3.85%. Therefore, the proposed electrochemical sensor is a potential candidate for the determination of ciprofloxacin in various matrices.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A Simple and Cost-effective Technique for Vertebroplasty
    Bharti, Ajay
    Swaroop, Anand
    Kumar, Pramod
    Rawat, Ashok
    TECHNIQUES IN ORTHOPAEDICS, 2015, 30 (01) : 29 - 31
  • [22] Simple CSII Is Highly Cost-Effective
    Henriksen, Ole
    Dall, Mads
    Warner, Jay
    Parkin, Christopher
    DIABETES, 2015, 64 : A350 - A350
  • [23] An efficient, cost-effective and simple solution
    British Dental Journal, 2019, 227 : 1073 - 1073
  • [24] A Simple, Cost-effective Microsuction Device
    Alfaqeeh, Faisal A.
    Alhusain, Abdullah M.
    Andejani, Doaa
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2023, 11 (09) : E5233
  • [25] Cost-Effective and Fast Fabrication of Copper-Cobalt Electrochemical Glucose Sensor
    Zeynalova, Aydan
    Oskay, Kuersad Oguz
    JOURNAL OF ELECTRONIC MATERIALS, 2023, 52 (10) : 6791 - 6799
  • [26] A simple and cost-effective manual solid phase extraction method for the determination of nanomolar dissolved reactive phosphorus in aqueous samples
    Yuan, Yuan
    Wang, Shu
    Yuan, Dongxing
    Ma, Jian
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2016, 14 (02): : 79 - 86
  • [27] An Electrochemical Sensor for Ultrasensitive Determination the Polychlorinated Biphenyls
    Zheng, Xiangli
    Li, Hongli
    Xia, Fangquan
    Tian, Dong
    Hua, Xiaoxia
    Qiao, Xueying
    Zhou, Changli
    ELECTROCHIMICA ACTA, 2016, 194 : 413 - 421
  • [28] A simple, rapid, cost-effective and sensitive method for detection of Salmonella in environmental and pecan samples
    Dobhal, S.
    Zhang, G.
    Rohla, C.
    Smith, M. W.
    Ma, L. M.
    JOURNAL OF APPLIED MICROBIOLOGY, 2014, 117 (04) : 1181 - 1190
  • [29] A Cost-Effective Electrochemical Sensor Using a Graphite Pencil Electrode for Sensitive Quantification of Phenolic Antioxidants in Human Plasma and Food Samples
    Bakr, Ahmed
    Newair, Emad F.
    Ismael, Mohamed
    Khairy, Mohamed
    ELECTROANALYSIS, 2025, 37 (01)
  • [30] An ultrasensitive and selective 'turn off' fluorescent sensor with simple operation for the determination of trace copper (II) ions in water and various beverage samples
    Elmas, Sukriye Nihan Karuk
    Gunay, Ibrahim Berk
    Koran, Kenan
    Ozen, Furkan
    Aydin, Duygu
    Arslan, Fatma Nur
    Gorgulu, Ahmet Orhan
    Yilmaz, Ibrahim
    SUPRAMOLECULAR CHEMISTRY, 2019, 31 (12) : 756 - 766