Development of a complete simulation package for Self-Powered Neutron Detectors using the Monte Carlo Method and Geant4 toolkit

被引:1
|
作者
Li, Kun [1 ]
Li, Gang [1 ]
Wan, Bo [1 ]
Yang, Daibo [1 ]
Li, Dan [1 ]
Weng, Xiaohui [1 ]
Li, Ang [1 ]
Yin, Qiusheng [1 ]
Wang, Haibo [1 ]
机构
[1] Nucl Power Inst China, Sci & Technol Reactor Syst Design Technol Lab, Chengdu 610213, Peoples R China
基金
中国国家自然科学基金;
关键词
Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; Neutron detectors (cold; thermal; fast neutrons); MODEL;
D O I
10.1088/1748-0221/18/08/T08003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to provide guidance on the design and use of the Self-Powered Neutron Detector (SPND) and improve measurement accuracy, accurate simulation of SPND is required. Therefore, a complete SPND simulation package was developed, including a particle transport calculation module, an electric field calculation module, a visualization interface and a data post-processing module. Due to electric field produced by space charge in the insulator, Geant4 has been chosen as the particle transport calculation module and an iterative code for the electric field was written to implement the calculation of the electric field in the insulator. To help researchers simplify the process of writing codes, a wizard-like visual interface was developed based on QT for configuring the input files and for performing the calculations. The accuracy of the simulation package was verified by comparing it with other calculation codes. With the help of the simulation package, the user can very easily achieve an accurate simulation of the SPND.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Development of a Full Monte Carlo Therapeutic Dose Calculation Toolkit for Halcyon Using Geant4
    Liu, R.
    Ji, Z.
    Cai, B.
    Hugo, G.
    Mutic, S.
    Zhao, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E742 - E742
  • [12] A Monte Carlo method for quantitatively calculating the neutron sensitivity of rhodium self-powered neutron detectors in reactors
    Wu, Xiong
    Jiang, Jieqiong
    Wu, Tingyu
    Luo, Shijie
    [J]. RADIATION DETECTION TECHNOLOGY AND METHODS, 2024, 8 (02) : 1162 - 1170
  • [13] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [14] Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit
    Boudjella, Manal Yasmine
    Belbachir, Ahmed Hafid
    Dib, Samy Anis Amine
    Meftah, Mustapha
    [J]. JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2023, 248
  • [15] Recent Improvements in the Geant4 Monte Carlo Simulation Toolkit for Medical Physics Applications
    Perl, J.
    Faddegon, B.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2803 - +
  • [16] GATE/Geant4 as a Monte Carlo simulation toolkit for light ion beam dosimetry
    Bolsa-Ferruz, M.
    Palmans, H.
    Carlino, A.
    Stock, M.
    Traneus, E.
    Grevillot, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S727 - S728
  • [17] Development and verification of a simulation toolkit for Self-Powered Neutron Detector
    Sang, Yaodong
    Deng, Bangjie
    Zhang, Qingmin
    Shao, Ruizhi
    Sun, Bin
    Cao, Liangzhi
    Li, Yunzhao
    [J]. ANNALS OF NUCLEAR ENERGY, 2021, 150
  • [18] A comparison of cellular irradiation techniques with alpha particles using the Geant4 Monte Carlo simulation toolkit
    Incerti, S.
    Gault, N.
    Habchi, C.
    Lefaix, J. L.
    Moretto, Ph.
    Poncy, J. L.
    Pouthier, T.
    Seznec, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 122 (1-4) : 327 - 329
  • [19] A MONTE-CARLO CALCULATION OF THE NEUTRON AND GAMMA SENSITIVITIES OF SELF-POWERED DETECTORS
    PYTEL, K
    [J]. ATOMKERNENERGIE-KERNTECHNIK, 1981, 39 (01): : 31 - 37
  • [20] Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation
    Singh, Vishwanath P.
    Medhat, M. E.
    Badiger, N. M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 83 - 87