Study of a constrained finite element elbow prosthesis: the influence of the implant placement

被引:1
|
作者
Nalbone, Lorenzo [1 ]
Monac, Francesco [1 ]
Nalbone, Luca [2 ]
Ingrassia, Tommaso [3 ]
Ricotta, Vito [3 ]
Nigrelli, Vincenzo [3 ]
Ferruzza, Massimo [1 ]
Tarallo, Luigi [4 ]
Porcellini, Giuseppe [4 ]
Camarda, Lawrence [1 ]
机构
[1] Univ Palermo, Dept Orthoped & Traumatol DICHIRONS, Via Vespro, I-90100 Palermo, Italy
[2] Univ Messina, Dept Vet Sci, Messina, Italy
[3] Univ Palermo, Dept Engn, Palermo, Italy
[4] Univ Modena, Dept Orthoped & Traumatol, Modena, Italy
关键词
Totel elbow arthroplasty; Biomechanics; Elbow replacement; Prosthetic posizioning; Elbow finite element; ARTHROPLASTY; REPLACEMENT;
D O I
10.1186/s10195-023-00690-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions.Materials and methodsBy means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by +/- 3 degrees.ResultsThe greatest von Mises stress state in the bone component for the 90 degrees working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0 degrees and 145 degrees showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90 degrees (- 3 degrees in the sagittal plane, 0 degrees in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement.ConclusionThe areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90 degrees. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.Level of evidence: 5
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Influence of implants number on the biomechanical behavior of implant-supported complete prosthesis: A 3D finite element analysis
    Aguir, Hamdi
    Mabrouk, Yosra
    Chamekh, Rayene
    Saadellaoui, Ines
    HELIYON, 2023, 9 (07)
  • [42] The Influence of Various Superstructure Materials on Stress Distribution for Implant-Supported Prosthesis: Three-Dimensional Finite Element Analysis
    Jameel, Rawan Mufeed
    Al-Khafaji, Aseel Mohammed
    PROSTHESIS, 2024, 6 (05): : 1133 - 1148
  • [43] The effect of implant design of linked total elbow arthroplasty on stability and stress: a finite element analysis
    Willing, Ryan
    King, Graham J. W.
    Johnson, James A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (11) : 1165 - 1172
  • [44] Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Souto Borges, Alexandre Luiz
    Rodrigues, Vinicius Aneas
    Bottino, Marco Antonio
    Kleverlaan, Cornelis Johannes
    JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (02): : 67 - 74
  • [45] Effects of Daily Mastication on Bone Remodeling With Implant-Tooth-Supported Fixed Partial Prosthesis: A Finite Element Study
    Zhang, Guangming
    Zhang, Yonghong
    Fu, Xiaoming
    Zhang, Xiaonan
    IEEE ACCESS, 2019, 7 : 33851 - 33858
  • [46] Implant biomechanics relating to the dental implant and prosthesis design: In-vitro strain gauge analysis and finite element analysis
    Shaukat, Aqsa
    Zehra, Nida
    Kaleem, Muhammad
    Fareed, Muhammad Amber
    AIP ADVANCES, 2024, 14 (04)
  • [47] Interactive imaging for implant planning, placement, and prosthesis construction
    Parel, SM
    Triplett, RG
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (09) : 41 - 47
  • [48] Comparison of implant placement at crestal and subcrestal levels in aesthetic zone: A finite element analysis
    Ozer, Taha
    Acar, Gulin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [49] The effect of implant splinting on the load distribution in bone bed around implant-supported fixed prosthesis with different framework materials: A finite element study
    Hasan, I.
    Bourauel, C.
    Keilig, L.
    Stark, H.
    Lueckerath, W.
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2015, 199 : 43 - 51
  • [50] 3-DIMENSIONAL FINITE-ELEMENT ANALYSIS OF IMPLANT PROSTHESIS DURING CHEWING MOVEMENT
    NAKANO, T
    INUI, Y
    MATSUZAKI, D
    NAKANO, H
    KATO, K
    TSUKAMOTO, H
    YAMADA, S
    TAKASHIMA, F
    MARUYAMA, T
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 979 - 979