Study of a constrained finite element elbow prosthesis: the influence of the implant placement

被引:1
|
作者
Nalbone, Lorenzo [1 ]
Monac, Francesco [1 ]
Nalbone, Luca [2 ]
Ingrassia, Tommaso [3 ]
Ricotta, Vito [3 ]
Nigrelli, Vincenzo [3 ]
Ferruzza, Massimo [1 ]
Tarallo, Luigi [4 ]
Porcellini, Giuseppe [4 ]
Camarda, Lawrence [1 ]
机构
[1] Univ Palermo, Dept Orthoped & Traumatol DICHIRONS, Via Vespro, I-90100 Palermo, Italy
[2] Univ Messina, Dept Vet Sci, Messina, Italy
[3] Univ Palermo, Dept Engn, Palermo, Italy
[4] Univ Modena, Dept Orthoped & Traumatol, Modena, Italy
关键词
Totel elbow arthroplasty; Biomechanics; Elbow replacement; Prosthetic posizioning; Elbow finite element; ARTHROPLASTY; REPLACEMENT;
D O I
10.1186/s10195-023-00690-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions.Materials and methodsBy means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by +/- 3 degrees.ResultsThe greatest von Mises stress state in the bone component for the 90 degrees working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0 degrees and 145 degrees showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90 degrees (- 3 degrees in the sagittal plane, 0 degrees in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement.ConclusionThe areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90 degrees. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.Level of evidence: 5
引用
收藏
页数:13
相关论文
共 50 条
  • [21] The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study
    Yuan, Wei
    Zhang, Haiping
    Zhou, Xiaoshu
    Wu, Weidong
    Zhu, Yue
    WORLD NEUROSURGERY, 2018, 113 : E490 - E498
  • [22] Influence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study
    Londono, J. J.
    Ramos, A.
    Correa, S.
    Mesnard, M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 : S178 - S179
  • [23] A Three - Dimensional Finite Element Analysis of Polyetheretherketone PEEK in Dental Implant Prosthesis: A Novel Implant System
    Al-Mortadi, Noor
    Bataineh, Khaled
    Albakri, Isra
    OPEN DENTISTRY JOURNAL, 2022, 16
  • [24] Influence of Implant Location, Number, and Design in Ischemic Zone for Implant Prosthesis Success Rate: A Comparative Three-Dimensional Finite Element Analysis
    Sayed, Arshad J.
    Garg, Kamlesh K.
    Mohan, Sasankoti R.
    Tareen, Sabahat Ullah Khan
    Shankar, Bugude Shiva
    Omran, Mostafa H.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [25] Finite element modeling to predict the influence of anatomic variation and implant placement on performance of biological intervertebral disc implants
    Koga, Maho
    Kim, Byumsu
    Lintz, Marianne
    Kirnaz, Sertac
    Goldberg, Jacob L.
    Hussain, Ibrahim
    Medary, Branden
    Meyers, Kathleen N.
    Maher, Suzanne A.
    Hartl, Roger
    Bonassar, Lawrence J.
    JOR SPINE, 2023, 6 (04):
  • [26] Investigation of Influence of Different Implant Size and Placement on Stress Distribution With 3-Dimensional Finite Element Analysis
    Balkaya, Mehmet Cudi
    IMPLANT DENTISTRY, 2014, 23 (06) : 716 - 722
  • [27] Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study
    Gumrukcu, Zeynep
    Korkmaz, Yavuz Tolga
    Korkmaz, Fatih Mehmet
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 86 : 47 - 54
  • [28] Non-anatomical placement adversely affects the functional performance of the meniscal implant: a finite element study
    Shriram, Duraisamy
    Yamako, Go
    Kumar, Gideon Praveen
    Chosa, Etsuo
    Cui, Fangsen
    Subburaj, Karupppasamy
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (03) : 1167 - 1185
  • [29] Non-anatomical placement adversely affects the functional performance of the meniscal implant: a finite element study
    Duraisamy Shriram
    Go Yamako
    Gideon Praveen Kumar
    Etsuo Chosa
    Fangsen Cui
    Karupppasamy Subburaj
    Biomechanics and Modeling in Mechanobiology, 2021, 20 : 1167 - 1185
  • [30] Comparative biomechanics of all-on-4 and vertical implant placement in asymmetrical mandibular: a finite element study
    Sun, Xin
    Tang, Xiaodong
    Cheng, Kangjie
    Xia, Zhuoheng
    Liu, Yunfeng
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2024, 24 (01):