Experimental research on the cross-infection control performance of different ventilation strategies

被引:1
|
作者
Li, Han [1 ]
Lan, Yuer [1 ]
Liu, Musong [1 ]
Kong, Xiangfei [1 ]
Fan, Man [1 ]
机构
[1] Hebei Univ Technol, Sch Energy & Environm Engn, Tianjin 300401, Peoples R China
基金
中国国家自然科学基金;
关键词
Cross -infection control; Interactive ventilation; Max long-term exposure; Human health microenvironment; TRANSMISSION; ENVIRONMENT; FREQUENCY; TRANSPORT; DROPLETS; COUGH;
D O I
10.1016/j.buildenv.2023.110683
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sustained pandemics have awakened the growing need to select appropriate indoor ventilation strategies to create a healthy environment. Hence, this study experimentally evaluated the cross-infection control performance of different ventilation strategies, namely mixing ventilation with outlets installed in the bottom of the side wall (MV-BR) and at ceilings (MV-CR), stratum ventilation with outlets installed in the side wall (SV-SR) and at ceilings (SV-CR), interactive cascade ventilation with outlets installed in the side wall (ICV-SR) and at ceilings (ICV-CR). The supply air flow rate of the studied ventilation strategies remains the same (6.51 h-1) for fair comparison. The infection risk and maximum cumulative exposure are introduced as the evaluation indicators. The research results show that the mean infection risk in the respiratory zone of susceptible individuals who are standing in the sidewind directions of the infected people under ICV-SR has the lowest potential infection risk (Pi) value of 0.012, which is consistently lower than ICV-CR by 8.3%, MV-CR by 42%, MV-BR by 45%, SV-CR by 50%, and SV-SR by 55%, respectively. And the average max long-term exposure of MV-BR is 15.2% lower than MV-CR. Compared with SV-CR and ICV-CR, SV-SR and ICV-SR can also realize to reduce the max long-term exposure by 21.3% and 25%, respectively. The integrated scenario index calculation results demonstrate that ICV presents excellent cross-infection control performance than SV and MV, obtaining 53.5% and 61.2% lower cross-infection risk. The conclusions got from this study can provide guide for the design of indoor airflow organization with the epidemic normalizing.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [41] ROLE OF ULTRASONIC CLEANING IN CONTROL OF CROSS-INFECTION IN DENTISTRY
    WATMOUTH
    ULTRASONICS, 1994, 32 (04) : 315 - 317
  • [42] Cross-infection control in dental practice in the Republic of Ireland
    Kearns, HPO
    Burke, FJT
    Cheung, SW
    INTERNATIONAL DENTAL JOURNAL, 2001, 51 (01) : 17 - 22
  • [43] CONTROL OF STAPHYLOCOCCAL CROSS-INFECTION IN 3 SURGICAL WARDS
    ALDER, VG
    GILLESPIE, WA
    JOURNAL OF CLINICAL PATHOLOGY, 1960, 13 (06) : 535 - 536
  • [44] THE USE OF GLOVES IN CROSS-INFECTION CONTROL - A HISTORICAL NOTE
    BURKE, FJT
    WILSON, NHF
    BRITISH DENTAL JOURNAL, 1989, 166 (11) : 426 - 428
  • [45] IRREDUCIBLE MINIMUM IN CROSS-INFECTION CONTROL AND ISOLATION NURSING
    HUGHES, WH
    JOURNAL OF HYGIENE-CAMBRIDGE, 1970, 68 (03): : 379 - &
  • [46] Public perception of cross-infection control in dentistry in Nigeria
    Sofola, OO
    Uti, OG
    Onigbinde, OO
    INTERNATIONAL DENTAL JOURNAL, 2005, 55 (06) : 383 - 387
  • [47] Cross-infection and infection control in dental clinics in Nablus and Tulkarm districts
    Wafaa Menawi
    Areej Sabbah
    Lubna Kharraz
    BMC Microbiology, 21
  • [48] Cross-infection and infection control in dental clinics in Nablus and Tulkarm districts
    Menawi, Wafaa
    Sabbah, Areej
    Kharraz, Lubna
    BMC MICROBIOLOGY, 2021, 21 (01)
  • [49] Influence of pulmonary ventilation rate and breathing cycle period on the risk of cross-infection
    Ai, Zhengtao
    Hashimoto, Kaho
    Melikov, Arsen K.
    INDOOR AIR, 2019, 29 (06) : 993 - 1004
  • [50] The risk of airborne cross-infection in a room with vertical low-velocity ventilation
    Olmedo, I.
    Nielsen, P. V.
    Ruiz de Adana, M.
    Jensen, R. L.
    INDOOR AIR, 2013, 23 (01) : 62 - 73