Influence of pulmonary ventilation rate and breathing cycle period on the risk of cross-infection

被引:41
|
作者
Ai, Zhengtao [1 ]
Hashimoto, Kaho [1 ,2 ]
Melikov, Arsen K. [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, Copenhagen, Denmark
[2] Waseda Univ, Fac Sci & Engn, Dept Architecture, Tokyo, Japan
关键词
airborne transmission; breathing cycle period; chamber experiment; human exhalation; human exposure; pulmonary ventilation rate; PERSONALIZED VENTILATION; SPATIAL-DISTRIBUTION; THERMAL MANNEQUINS; DYNAMIC PROPERTIES; AIR-DISTRIBUTION; HOSPITAL WARD; EXHALED AIR; EXPOSURE; ROOM; FLOW;
D O I
10.1111/ina.12589
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examined the characteristics of the exhaled airflow pattern and breathing cycle period of human subjects and evaluated the influence of pulmonary ventilation rate and breathing cycle period on the risk of cross-infection. Measurements with five human subjects and a breathing thermal manikin were performed, and the peak exhaled airflow velocity from the mouth and the breathing cycle period were measured. Experiments on cross-infection between two breathing thermal manikins were then conducted in a full-scale test room, in which the pulmonary ventilation rate and breathing cycle period were varied systematically. Both peak flow velocity and breathing cycle length varied considerably between different subjects. The breathing cycle period in a standing posture was 18.9% lower than in a sitting posture. The influence of pulmonary ventilation rate and breathing cycle period extended up to a separation distance of 1.0 m between the two manikins. Increasing the pulmonary ventilation rate of the exposed person greatly increased the risk of cross-infection. Decreasing the breathing cycle period from the widely used "6 second" value led to a considerable increase in the risk of cross-infection. Standing posture resulted in a higher risk of cross-infection than sitting posture.
引用
下载
收藏
页码:993 / 1004
页数:12
相关论文
共 50 条
  • [1] Breathing and Cross-Infection Risk in the Microenvironment around People
    Nielsen, Peter V.
    Zajas, Jan
    Litewnicki, Michal
    Jensen, Rasmus L.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120
  • [2] Risk of cross-infection in a hospital ward with downward ventilation
    Nielsen, Peter V.
    Li, Yuguo
    Buus, Morten
    Winther, Frederik V.
    BUILDING AND ENVIRONMENT, 2010, 45 (09) : 2008 - 2014
  • [3] The risk of airborne cross-infection in a room with vertical low-velocity ventilation
    Olmedo, I.
    Nielsen, P. V.
    Ruiz de Adana, M.
    Jensen, R. L.
    INDOOR AIR, 2013, 23 (01) : 62 - 73
  • [4] A CROSS-INFECTION MODEL WITH DIFFUSION AND INCUBATION PERIOD
    Pang, Danfeng
    Xiao, Yanni
    Zhao, Xiao-qiang
    DISCRETE AND CONTINUOUS DYNAMICAL SYSTEMS-SERIES B, 2022, 27 (11): : 6269 - 6294
  • [5] CROSS-INFECTION RISK IN NURSING-HOMES
    CORLETT, SK
    CURRENT OPINION IN INFECTIOUS DISEASES, 1994, 7 (04) : 475 - 478
  • [6] Influence of human breathing modes on airborne cross infection risk
    Villafruela, J. M.
    Olmedo, I.
    San Jose, J. F.
    BUILDING AND ENVIRONMENT, 2016, 106 : 340 - 351
  • [7] Cross-contamination and cross-infection risk of otoscope heads
    Korkmaz, Hakan
    Cetinkol, Yeliz
    Korkmaz, Mukadder
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (12) : 3183 - 3186
  • [8] Cross-contamination and cross-infection risk of otoscope heads
    Hakan Korkmaz
    Yeliz Çetinkol
    Mukadder Korkmaz
    European Archives of Oto-Rhino-Laryngology, 2013, 270 : 3183 - 3186
  • [9] Experimental research on the cross-infection control performance of different ventilation strategies
    Li, Han
    Lan, Yuer
    Liu, Musong
    Kong, Xiangfei
    Fan, Man
    BUILDING AND ENVIRONMENT, 2023, 243
  • [10] Exhaled gases and the potential for cross-infection via noninvasive ventilation machines
    Messer, Benjamin
    Armstrong, Alison Dawn
    Lane, Nicholas David
    Robb, Ali
    Bullock, Robert Edward
    ERJ OPEN RESEARCH, 2022, 8 (03)