Influence of pulmonary ventilation rate and breathing cycle period on the risk of cross-infection

被引:41
|
作者
Ai, Zhengtao [1 ]
Hashimoto, Kaho [1 ,2 ]
Melikov, Arsen K. [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, Copenhagen, Denmark
[2] Waseda Univ, Fac Sci & Engn, Dept Architecture, Tokyo, Japan
关键词
airborne transmission; breathing cycle period; chamber experiment; human exhalation; human exposure; pulmonary ventilation rate; PERSONALIZED VENTILATION; SPATIAL-DISTRIBUTION; THERMAL MANNEQUINS; DYNAMIC PROPERTIES; AIR-DISTRIBUTION; HOSPITAL WARD; EXHALED AIR; EXPOSURE; ROOM; FLOW;
D O I
10.1111/ina.12589
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examined the characteristics of the exhaled airflow pattern and breathing cycle period of human subjects and evaluated the influence of pulmonary ventilation rate and breathing cycle period on the risk of cross-infection. Measurements with five human subjects and a breathing thermal manikin were performed, and the peak exhaled airflow velocity from the mouth and the breathing cycle period were measured. Experiments on cross-infection between two breathing thermal manikins were then conducted in a full-scale test room, in which the pulmonary ventilation rate and breathing cycle period were varied systematically. Both peak flow velocity and breathing cycle length varied considerably between different subjects. The breathing cycle period in a standing posture was 18.9% lower than in a sitting posture. The influence of pulmonary ventilation rate and breathing cycle period extended up to a separation distance of 1.0 m between the two manikins. Increasing the pulmonary ventilation rate of the exposed person greatly increased the risk of cross-infection. Decreasing the breathing cycle period from the widely used "6 second" value led to a considerable increase in the risk of cross-infection. Standing posture resulted in a higher risk of cross-infection than sitting posture.
引用
下载
收藏
页码:993 / 1004
页数:12
相关论文
共 50 条
  • [11] Protected zone ventilation and reduced personal exposure to airborne cross-infection
    Cao, G.
    Nielsen, P. V.
    Jensen, R. L.
    Heiselberg, P.
    Liu, L.
    Heikkinen, J.
    INDOOR AIR, 2015, 25 (03) : 307 - 319
  • [12] The reuse of opthalmic minims®: an unacceptable cross-infection risk?
    Rautenbach, P.
    Wilson, A.
    Gouws, P.
    EYE, 2010, 24 (01) : 50 - 52
  • [13] The reuse of ophthalmic minims: an unacceptable cross-infection risk?
    Y C Yap
    M Smith
    D Byles
    Eye, 2010, 24 : 1421 - 1422
  • [14] The reuse of ophthalmic minims: an unacceptable cross-infection risk?
    Yap, Y. C.
    Smith, M.
    Byles, D.
    EYE, 2010, 24 (08) : 1421 - 1422
  • [15] RISK OF CROSS-INFECTION FROM INHALATION ANAESTHETIC EQUIPMENT
    PANDIT, SK
    MEHTA, S
    AGARWAL, SC
    BRITISH JOURNAL OF ANAESTHESIA, 1967, 39 (11) : 838 - &
  • [16] The reuse of opthalmic minims®: an unacceptable cross-infection risk?
    P Rautenbach
    A Wilson
    P Gouws
    Eye, 2010, 24 : 50 - 52
  • [17] THE ASSESSMENT OF THE RISK OF CROSS-INFECTION WITH A MULTIUSE NASAL ATOMIZER
    SPRAGGS, PDR
    HANEKOM, WV
    MOCHLOULIS, G
    JOSEPH, T
    KELSEY, MC
    JOURNAL OF HOSPITAL INFECTION, 1994, 28 (04) : 315 - 321
  • [18] RISK OF CROSS-INFECTION THROUGH SHARED DIABETIC DEVICES
    SHALIT, P
    BRENNAN, C
    MURPHY, V
    HOOTON, TM
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (01): : 34 - 35
  • [19] Experimental Study of the Cross-infection Risk due to the Cross-flow of Exhaled Airflows and a Plane Jet with the Protected Occupied Zone Ventilation
    Cao, Guangyu
    Nielsen, Peter V.
    Xu, Chunwen
    Jensen, Rasmus Lund
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 2, 2014, 120
  • [20] Risk of DUWLs viral cross-infection: the HCV model.
    Artini, M
    Dolci, G
    De Luca, M
    Berlutti, F
    Montebugnoli, L
    Callari, A
    Selan, L
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A111 - A111