Impact of Reduced Image Noise on Deauville Scores in Patients with Lymphoma Scanned on a Long-Axial Field-of-View PET/CT-Scanner

被引:2
|
作者
Korsholm, Kirsten [1 ]
Overbeck, Nanna [1 ]
Dias, Andre H. [2 ,3 ]
Loft, Annika [1 ]
Andersen, Flemming Littrup [1 ,4 ]
Fischer, Barbara Malene [1 ,4 ]
机构
[1] Rigshospitalet, Dept Clin Physiol & Nucl Med, DK-2100 Copenhagen, Denmark
[2] Aarhus Univ Hosp, Dept Nucl Med, DK-8200 Aarhus, Denmark
[3] Aarhus Univ Hosp, PET Ctr, DK-8200 Aarhus, Denmark
[4] Univ Copenhagen, Dept Clin Med, DK-2200 Copenhagen, Denmark
关键词
LAFOV; Deauville score; lymphoma; PET; CT; reconstruction methods; POSITRON-EMISSION-TOMOGRAPHY; STANDARDIZED UPTAKE VALUE; METABOLIC TUMOR VOLUME; CELL; LIVER;
D O I
10.3390/diagnostics13050947
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Total body and long-axial field-of-view (LAFOV) PET/CT represent visionary innovations in imaging enabling either improved image quality, reduction in injected activity-dose or decreased acquisition time. An improved image quality may affect visual scoring systems, including the Deauville score (DS), which is used for clinical assessment of patients with lymphoma. The DS compares SUVmax in residual lymphomas with liver parenchyma, and here we investigate the impact of reduced image noise on the DS in patients with lymphomas scanned on a LAFOV PET/CT. Methods: Sixty-eight patients with lymphoma underwent a whole-body scan on a Biograph Vision Quadra PET/CT-scanner, and images were evaluated visually with regard to DS for three different timeframes of 90, 300, and 600 s. SUVmax and SUVmean were calculated from liver and mediastinal blood pool, in addition to SUVmax from residual lymphomas and measures of noise. Results: SUVmax in liver and in mediastinal blood pool decreased significantly with increasing acquisition time, whereas SUVmean remained stable. In residual tumor, SUVmax was stable during different acquisition times. As a result, the DS was subject to change in three patients. Conclusions: Attention should be drawn towards the eventual impact of improvements in image quality on visual scoring systems such as the DS.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] The clinical acceptability of short versus long duration acquisitions for head and neck cancer using long-axial field-of-view PET/CT: a retrospective evaluation
    Riccardo Mei
    Thomas Pyka
    Hasan Sari
    Stefano Fanti
    Ali Afshar-Oromieh
    Roland Giger
    Federico Caobelli
    Axel Rominger
    Ian Alberts
    European Journal of Nuclear Medicine and Molecular Imaging, 2024, 51 : 1436 - 1443
  • [42] Long-axial field-of-view PET/CT for the assessment of inflammation in calcified coronary artery plaques with [68 Ga]Ga-DOTA-TOC
    Clemens Mingels
    Hasan Sari
    Nasir Gözlügöl
    Carola Bregenzer
    Luisa Knappe
    Korbinian Krieger
    Ali Afshar-Oromieh
    Thomas Pyka
    Lorenzo Nardo
    Christoph Gräni
    Ian Alberts
    Axel Rominger
    Federico Caobelli
    European Journal of Nuclear Medicine and Molecular Imaging, 2024, 51 : 422 - 433
  • [43] The clinical acceptability of short versus long duration acquisitions for head and neck cancer using long-axial field-of-view PET/CT: a retrospective evaluation
    Mei, Riccardo
    Pyka, Thomas
    Sari, Hasan
    Fanti, Stefano
    Afshar-Oromieh, Ali
    Giger, Roland
    Caobelli, Federico
    Rominger, Axel
    Alberts, Ian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (05) : 1436 - 1443
  • [44] Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction
    Jakoby, Bjoern W.
    Bercier, Yanic
    Watson, Charles C.
    Bendriem, Bernard
    Townsend, David W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 633 - 639
  • [45] Achieving EARL Accreditation on a Long Axial Field-of-View (LAFOV) PET/CT System
    Holman, B.
    Willson, T.
    Ferreira, B.
    Davis, N.
    McCool, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S722 - S722
  • [46] Long-axial field-of-view PET/CT for the assessment of inflammation in calcified coronary artery plaques with [68 Ga]Ga-DOTA-TOC
    Mingels, Clemens
    Sari, Hasan
    Gozlugol, Nasir
    Bregenzer, Carola
    Knappe, Luisa
    Krieger, Korbinian
    Afshar-Oromieh, Ali
    Pyka, Thomas
    Nardo, Lorenzo
    Grani, Christoph
    Alberts, Ian
    Rominger, Axel
    Caobelli, Federico
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (02) : 422 - 433
  • [47] Long axial field-of-view PET/CT devices: are we ready for the technological revolution?
    Filippi, Luca
    Dimitrakopoulou-Strauss, Antonia
    Evangelista, Laura
    Schillaci, Orazio
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (10) : 739 - 743
  • [48] Dead time correction method for long axial field-of-view, whole-body PET scanner
    Tang, Songsong
    Liu, Yilin
    Wang, Jianxun
    Zhao, Yong
    Fan, Xin
    Dong, Yun
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [49] Long-axial field-of-view PET/CT scanners improve the detection of inflamed coronary artery plaques with 68Ga-DOTA-TOC imaging
    Mingels, Clemens
    Alberts, Ian
    Rominger, Axel
    Caobelli, Federico
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [50] Optimization of Y-90 Radioembolization Imaging for Post-Treatment Dosimetry on a Long Axial Field-of-View PET/CT Scanner
    Linder, Pia M.
    Lan, Wenhong
    Trautwein, Nils F.
    Brosch-Lenz, Julia
    von Beschwitz, Sebastian
    Kupferschlaeger, Juergen
    Reischl, Gerald
    Groezinger, Gerd
    Dittmann, Helmut
    la Fougere, Christian
    Schmidt, Fabian P.
    DIAGNOSTICS, 2023, 13 (22)