Impact of Reduced Image Noise on Deauville Scores in Patients with Lymphoma Scanned on a Long-Axial Field-of-View PET/CT-Scanner

被引:2
|
作者
Korsholm, Kirsten [1 ]
Overbeck, Nanna [1 ]
Dias, Andre H. [2 ,3 ]
Loft, Annika [1 ]
Andersen, Flemming Littrup [1 ,4 ]
Fischer, Barbara Malene [1 ,4 ]
机构
[1] Rigshospitalet, Dept Clin Physiol & Nucl Med, DK-2100 Copenhagen, Denmark
[2] Aarhus Univ Hosp, Dept Nucl Med, DK-8200 Aarhus, Denmark
[3] Aarhus Univ Hosp, PET Ctr, DK-8200 Aarhus, Denmark
[4] Univ Copenhagen, Dept Clin Med, DK-2200 Copenhagen, Denmark
关键词
LAFOV; Deauville score; lymphoma; PET; CT; reconstruction methods; POSITRON-EMISSION-TOMOGRAPHY; STANDARDIZED UPTAKE VALUE; METABOLIC TUMOR VOLUME; CELL; LIVER;
D O I
10.3390/diagnostics13050947
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Total body and long-axial field-of-view (LAFOV) PET/CT represent visionary innovations in imaging enabling either improved image quality, reduction in injected activity-dose or decreased acquisition time. An improved image quality may affect visual scoring systems, including the Deauville score (DS), which is used for clinical assessment of patients with lymphoma. The DS compares SUVmax in residual lymphomas with liver parenchyma, and here we investigate the impact of reduced image noise on the DS in patients with lymphomas scanned on a LAFOV PET/CT. Methods: Sixty-eight patients with lymphoma underwent a whole-body scan on a Biograph Vision Quadra PET/CT-scanner, and images were evaluated visually with regard to DS for three different timeframes of 90, 300, and 600 s. SUVmax and SUVmean were calculated from liver and mediastinal blood pool, in addition to SUVmax from residual lymphomas and measures of noise. Results: SUVmax in liver and in mediastinal blood pool decreased significantly with increasing acquisition time, whereas SUVmean remained stable. In residual tumor, SUVmax was stable during different acquisition times. As a result, the DS was subject to change in three patients. Conclusions: Attention should be drawn towards the eventual impact of improvements in image quality on visual scoring systems such as the DS.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Expert consensus on workflow of PET/CT with long axial field-of-view
    Liu, Guobing
    Gu, Yushen
    Sollini, Martina
    Lazar, Alexandra
    Besson, Florent L.
    Li, Sijin
    Wu, Zhifang
    Nardo, Lorenzo
    Al-Ibraheem, Akram
    Zheng, Jiefu
    Kulkarni, Harshad R.
    Rominger, Axel
    Fan, Wei
    Zhu, Xiaohua
    Zhao, Xinming
    Wu, Hubing
    Liu, Jianjun
    Li, Biao
    Cheng, Zhaoping
    Wang, Ruimin
    Xu, Baixuan
    Agostini, Denis
    Tang, Han
    Tan, Lijie
    Yang, Zhi
    Huo, Li
    Gu, Jianying
    Shi, Hongcheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (03) : 1038 - 1049
  • [22] First experiences with scanning patients with a long axial field of view PET/CT scanner
    Ferreira, B.
    Pritchard, A.
    Shirsavar, H.
    Leite, A.
    Wilson, T.
    McCool, D.
    Wagner, T.
    Holman, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S927 - S927
  • [23] Long Axial Field-of-View (LAFOV) PET/CT in Prostate Cancer
    Sachpekidis, Christos
    Dimitrakopoulou-Strauss, Antonia
    SEMINARS IN NUCLEAR MEDICINE, 2025, 55 (01) : 67 - 75
  • [24] Automated Quantitative Image-Derived Input Function for the Estimation of Cerebral Blood Flow Using Oxygen-15-Labelled Water on a Long-Axial Field-of-View PET/CT Scanner
    Andersen, Thomas Lund
    Andersen, Flemming Littrup
    Haddock, Bryan
    Rosenbaum, Sverre
    Larsson, Henrik Bo Wiberg
    Law, Ian
    Lindberg, Ulrich
    DIAGNOSTICS, 2024, 14 (15)
  • [25] Image Quality and Quantitative PET Parameters of Low-Dose [18F]FDG PET in a Long Axial Field-of-View PET/CT Scanner
    Calderon, Eduardo
    Schmidt, Fabian P.
    Lan, Wenhong
    Castaneda-Vega, Salvador
    Brendlin, Andreas S.
    Trautwein, Nils F.
    Dittmann, Helmut
    la Fougere, Christian
    Kiefer, Lena Sophie
    DIAGNOSTICS, 2023, 13 (20)
  • [26] Long-axial field-of-view PET/CT: perspectives and review of a revolutionary development in nuclear medicine based on clinical experience in over 7000 patients
    Alberts, Ian
    Sari, Hasan
    Mingels, Clemens
    Afshar-Oromieh, Ali
    Pyka, Thomas
    Shi, Kuangyu
    Rominger, Axel
    CANCER IMAGING, 2023, 23 (01)
  • [27] Long-axial field-of-view PET/CT: perspectives and review of a revolutionary development in nuclear medicine based on clinical experience in over 7000 patients
    Ian Alberts
    Hasan Sari
    Clemens Mingels
    Ali Afshar-Oromieh
    Thomas Pyka
    Kuangyu Shi
    Axel Rominger
    Cancer Imaging, 23
  • [28] Validating image-derived input functions in dynamic 18F-FDG PET scans acquired on a long-axial field-of-view PET/CT system
    Smith, Charlotte
    Yaqub, Maqsood
    Zwezerijnen, Gerben
    den Hollander, Marijke
    Zijlstra, Josee
    van Oordt, Catharina Menke-van der Houven
    Bahce, Idris
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [29] Impact of detector performance on images from a long axial field-of-view, whole-body PET scanner
    Surti, Suleman
    Karp, Joel
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [30] Impact of detector design on imaging performance of a long axial field-of-view, whole-body PET scanner
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (13): : 5343 - 5358