Characterization of Plastic Scintillator Detector for In Vivo Dosimetry in Gynecologic Brachytherapy

被引:1
|
作者
Herreros, Antonio [1 ,2 ]
Perez-Calatayud, Jose [3 ,4 ]
Ballester, Facundo [5 ]
Abellana, Rosa [1 ]
Neves, Joana [6 ]
Melo, Joana [6 ]
Moutinho, Luis [6 ]
Tarrats-Rosell, Jordi [2 ]
Serrano-Rueda, Sergi [2 ]
Tagliaferri, Luca [7 ]
Placidi, Elisa [7 ]
Rovirosa, Angeles [1 ,2 ,8 ]
机构
[1] Univ Barcelona, Fonaments Clin Dept, E-08036 Barcelona, Spain
[2] Hosp Clin Univ, Radiat Oncol Dept, Barcelona 08036, Spain
[3] Hosp Univ & Politecn La Fe, Radiat Oncol Dept, Valencia 46026, Spain
[4] Hosp Clin Benidorm, Radiat Oncol Dept, Alicante 03501, Spain
[5] IIS La Fe Univ Valencia UV, IRIMED, Burjassot 46100, Spain
[6] NU RISE SA, PCI Creat Sci Pk, P-3830352 Ilhavo, Portugal
[7] Fdn Policlin Univ A Gemelli IRCCS, Dipartimento Diagnost Immagini & Radioterapia Onco, I-00168 Rome, Italy
[8] Hosp Clin Univ, Gynecol Canc Unit, Barcelona 08036, Spain
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 03期
关键词
brachytherapy; in vivo dosimetry; plastic scintillator dosimeter; PHOTON; RECOMMENDATIONS; TEMPERATURE; FIBER; AAPM;
D O I
10.3390/jpm14030321
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
(1) Background: High dose gradients and manual steps in brachytherapy treatment procedures can lead to dose errors which make the use of in vivo dosimetry (IVD) highly recommended for verifying brachytherapy treatments. A new procedure was presented to obtain a calibration factor which allows fast and robust calibration of plastic scintillation detector (PSD) probes for the geometry of a compact phantom using Monte Carlo simulations. Additionally, characterization of PSD energy, angular, and temperature dependences was performed. (2) Methods: PENELOPE/PenEasy code was used to obtain the calibration factor. To characterize the energy dependence of the PSD, the signal was measured at different radial and transversal distances. The sensitivity to the angular position was characterized in axial and azimuthal planes. (3) Results: The calibration factor obtained allows for an absorbed dose to water determination in full scatter conditions from ionization measured in a mini polymethylmethacrylate (PMMA) phantom. The energy dependence of the PSD along the radial distances obtained was (2.3 +/- 2.1)% (k = 1). The azimuthal angular dependence measured was (2.6 +/- 3.4)% (k = 1). The PSD response decreased by (0.19 +/- 0.02)%/degrees C with increasing detector probe temperature. (4) Conclusions: The energy, angular, and temperature dependence of a PSD is compatible with IVD.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Miniaturized Scintillator Detector for in Vivo Dosimetry in HDR Brachytherapy
    Gonod, M.
    Suarez, M.
    Chacon, C.
    Crouzilles, J.
    Laskri, S.
    Vinchant, J.
    Grosjean, T.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E813 - E813
  • [2] Along-away table with a plastic scintillator detector for in vivo dosimetry in HDR brachytherapy
    Tarrats-Rosell, J.
    Herreros, A.
    Neves, J.
    Melo, J.
    Moutinho, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1500 - S1502
  • [3] Plastic Scintillation Detector Calibration Procedure for Brachytherapy in Vivo Dosimetry
    Herreros, A.
    Perez-Calatayud, J.
    Ballester, F.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E473 - E473
  • [4] Characterization of a new plastic scintillator detector system for small field dosimetry
    Mazzotta, B.
    Radici, L.
    Cutaia, C.
    Cirio, R.
    Stasi, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S736 - S737
  • [5] A high sensitivity plastic scintillation detector for in vivo dosimetry of LDR brachytherapy
    Therriault-Proulx, F.
    Beaulieu, L.
    Beddar, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S116 - S116
  • [6] Characterization of Plastic Scintillator W2 Detector in Small Field Dosimetry
    Galavis, P.
    Hu, L.
    Das, I.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E497 - E497
  • [7] PSD (plastic scintillation detector) in vivo dosimetry in post-operative endometrial brachytherapy
    Herreros, A.
    Melo, J.
    Moutinho, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1606 - S1607
  • [8] Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry
    Geso M.
    Robinson N.
    Schumer W.
    Williams K.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (1): : 5 - 10
  • [9] Characterization of a tissue equivalent plastic scintillator dosimetry system
    Petric, M
    Robar, J
    Clark, B
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2427 - 2427
  • [10] Characterization of a commercial plastic scintillator for electron FLASH dosimetry
    Oh, Kyuhak
    Hyun, Megan A.
    Gallagher, Kyle J.
    Yan, Ying
    Zhou, Sumin
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):