Characterization of a commercial plastic scintillator for electron FLASH dosimetry

被引:0
|
作者
Oh, Kyuhak [1 ]
Hyun, Megan A. [1 ]
Gallagher, Kyle J. [1 ]
Yan, Ying [1 ]
Zhou, Sumin [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE 68198 USA
来源
关键词
dosimetry; electron ultra-high dose rate (eFLASH); FLASH research extension (FLEX); plastic scintillator; BEAM DOSIMETRY; ION RECOMBINATION;
D O I
10.1002/acm2.14451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems.Methods and materialsWe assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film.ResultsWe observed that the 1 x 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 x 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of similar to 1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies.ConclusionsThis study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Novel Plastic Scintillator for Online Dosimetry in Electron FLASH-RT
    Poirier, Y.
    Xu, J.
    Ahmady, A.
    Mossahebi, S.
    Zhang, H.
    Therriault-Proulx, F.
    Sawant, A.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Characterization of a novel plastic scintillator for instant real-time dosimetry in electron FLASH-RT
    Poirier, Yannick
    Xu, Junliang
    Ahmady, Amir
    Mossahebi, Sina
    Zhang, Hong
    Therriault-Proulx, Francois
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2021, 48 (08) : 4666 - 4667
  • [3] Characterization of a tissue equivalent plastic scintillator dosimetry system
    Petric, M
    Robar, J
    Clark, B
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2427 - 2427
  • [4] Experimental characterization and Monte Carlo simulation of scintillator detectors in online electron FLASH radiotherapy dosimetry
    Morrocchi, Matteo
    Pensavalle, Jake Harold
    Ciarrocchi, Esther
    Di Martino, Fabio
    Felici, Giuseppe
    Galante, Federica
    Gasparini, Alessia
    Grasso, Luigi
    Linsalata, Stefania
    Massa, Maurizio
    Moggi, Andrea
    Pacitti, Matteo
    Vanreusel, Verdi
    Verellen, Dirk
    Bisogni, Maria Giuseppina
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (09)
  • [5] PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY
    Kim, Yewon
    Yoo, Hyunjun
    Kim, Chankyu
    Lim, Kyung Taek
    Moon, Myungkook
    Kim, Jongyul
    Cho, Gyuseong
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 187 - 190
  • [6] Technical note: Characterization and practical applications of a novel plastic scintillator for online dosimetry for an ultrahigh dose rate (FLASH)
    Poirier, Yannick
    Xu, Junliang
    Mossahebi, Sina
    Therriault-Proulx, Francois
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2022, 49 (07) : 4682 - 4692
  • [7] Characterization of Plastic Scintillator Detector for In Vivo Dosimetry in Gynecologic Brachytherapy
    Herreros, Antonio
    Perez-Calatayud, Jose
    Ballester, Facundo
    Abellana, Rosa
    Neves, Joana
    Melo, Joana
    Moutinho, Luis
    Tarrats-Rosell, Jordi
    Serrano-Rueda, Sergi
    Tagliaferri, Luca
    Placidi, Elisa
    Rovirosa, Angeles
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (03):
  • [8] Scintillator characterization in an electron FLASH beam: first experiences
    Vanreusel, V.
    Gasparini, A.
    Giammanco, A.
    Pacitti, M.
    Cociorb, M.
    Agostino, E. D'
    Felici, G.
    Verellen, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S775 - S775
  • [9] Point scintillator dosimetry in ultra-high dose rate electron "FLASH" radiation therapy: A first characterization
    Vanreusel, Verdi
    Gasparini, Alessia
    Galante, Federica
    Mariani, Giulia
    Pacitti, Matteo
    Cociorb, Madalina
    Giammanco, Andrea
    Reniers, Brigitte
    Reulens, Nathalie
    Shonde, Tunde Blessed
    Vallet, Hugo
    Vandenbroucke, Dirk
    Peeters, Marc
    Leblans, Paul
    Ma, Biwu
    Felici, Giuseppe
    Verellen, Dirk
    Nascimento, Luana de Freitas
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 103 : 127 - 137
  • [10] Plastic scintillator dosimetry in radiology applications
    Oliveira, Carmen H.
    Rego, Florbela
    Peralta, Luis
    Abreu, Maria C.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1612 - 1615