Characterization of Plastic Scintillator Detector for In Vivo Dosimetry in Gynecologic Brachytherapy

被引:1
|
作者
Herreros, Antonio [1 ,2 ]
Perez-Calatayud, Jose [3 ,4 ]
Ballester, Facundo [5 ]
Abellana, Rosa [1 ]
Neves, Joana [6 ]
Melo, Joana [6 ]
Moutinho, Luis [6 ]
Tarrats-Rosell, Jordi [2 ]
Serrano-Rueda, Sergi [2 ]
Tagliaferri, Luca [7 ]
Placidi, Elisa [7 ]
Rovirosa, Angeles [1 ,2 ,8 ]
机构
[1] Univ Barcelona, Fonaments Clin Dept, E-08036 Barcelona, Spain
[2] Hosp Clin Univ, Radiat Oncol Dept, Barcelona 08036, Spain
[3] Hosp Univ & Politecn La Fe, Radiat Oncol Dept, Valencia 46026, Spain
[4] Hosp Clin Benidorm, Radiat Oncol Dept, Alicante 03501, Spain
[5] IIS La Fe Univ Valencia UV, IRIMED, Burjassot 46100, Spain
[6] NU RISE SA, PCI Creat Sci Pk, P-3830352 Ilhavo, Portugal
[7] Fdn Policlin Univ A Gemelli IRCCS, Dipartimento Diagnost Immagini & Radioterapia Onco, I-00168 Rome, Italy
[8] Hosp Clin Univ, Gynecol Canc Unit, Barcelona 08036, Spain
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 03期
关键词
brachytherapy; in vivo dosimetry; plastic scintillator dosimeter; PHOTON; RECOMMENDATIONS; TEMPERATURE; FIBER; AAPM;
D O I
10.3390/jpm14030321
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
(1) Background: High dose gradients and manual steps in brachytherapy treatment procedures can lead to dose errors which make the use of in vivo dosimetry (IVD) highly recommended for verifying brachytherapy treatments. A new procedure was presented to obtain a calibration factor which allows fast and robust calibration of plastic scintillation detector (PSD) probes for the geometry of a compact phantom using Monte Carlo simulations. Additionally, characterization of PSD energy, angular, and temperature dependences was performed. (2) Methods: PENELOPE/PenEasy code was used to obtain the calibration factor. To characterize the energy dependence of the PSD, the signal was measured at different radial and transversal distances. The sensitivity to the angular position was characterized in axial and azimuthal planes. (3) Results: The calibration factor obtained allows for an absorbed dose to water determination in full scatter conditions from ionization measured in a mini polymethylmethacrylate (PMMA) phantom. The energy dependence of the PSD along the radial distances obtained was (2.3 +/- 2.1)% (k = 1). The azimuthal angular dependence measured was (2.6 +/- 3.4)% (k = 1). The PSD response decreased by (0.19 +/- 0.02)%/degrees C with increasing detector probe temperature. (4) Conclusions: The energy, angular, and temperature dependence of a PSD is compatible with IVD.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Surface preparation and coupling in plastic scintillator dosimetry
    Département de Physique, de Génie Physique et d'Optique, Université Laval, Québec City, Que. G1K7P4, Canada
    不详
    不详
    不详
    [J]. Med. Phys., 9 (3519-3525):
  • [32] In vivo dosimetry in pelvic brachytherapy
    Houlihan, Orla Anne
    Workman, Geraldine
    Hounsell, Alan R.
    Prise, Kevin M.
    Jain, Suneil
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1137):
  • [33] In-vivo dosimetry in brachytherapy
    Cygler, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S55 - S55
  • [34] Plastic scintillator centrality detector for BRAHMS
    Lee, YK
    Debbe, R
    Lee, JH
    Ito, H
    Sanders, SJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (2-3): : 281 - 287
  • [35] Energy Calibration of Plastic Scintillator Detector
    Stribrnsky, Branislav
    Petriska, Martin
    Hinca, Robert
    [J]. APPLIED PHYSICS OF CONDENSED MATTER (APCOM 2019), 2019, 2131
  • [36] Plastic scintillator preparation and coupling in scintillation dosimetry
    Archambault, L.
    Ayotte, G.
    Gingras, L.
    Beddar, A.
    Beaulieu, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2129 - 2130
  • [37] Preliminary Characterization of an Active CMOS Pad Detector for Tracking and Dosimetry in HDR Brachytherapy
    Bui, Thi Ngoc Hang
    Large, Matthew
    Poder, Joel
    Bucci, Joseph
    Bianco, Edoardo
    Giampaolo, Raffaele Aaron
    Rivetti, Angelo
    Da Rocha Rolo, Manuel
    Pastuovic, Zeljko
    Corradino, Thomas
    Pancheri, Lucio
    Petasecca, Marco
    [J]. SENSORS, 2024, 24 (02)
  • [38] USE OF SCINTILLATOR PHOTODIODE DETECTOR IN COUNTING MODE IN DOSIMETRY
    DANSHIN, EA
    PIVEN, LA
    RYZHIKOV, VD
    SELEGENEV, EM
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (04) : 807 - 810
  • [39] Characterization of a new MOSFET detector configuration for in vivo skin dosimetry
    Scalchi, P
    Francescon, P
    Rajaguru, P
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1571 - 1578
  • [40] Doped Plastic Scintillator Properties for Soft Tissue Dosimetry
    Tajudin, S. M.
    Namito, Y.
    Sanami, T.
    Hirayama, H.
    Hashim, S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (09) : 2108 - 2112