Sub-calcaneal plantar fat pad assessment using dual-energy computed tomography: First experience in the diabetic foot

被引:0
|
作者
Mens, M. A. [1 ,6 ,8 ]
Fassaert, T. F. [1 ,6 ]
Homan, J. H. [1 ,6 ]
Busch-Westbroek, T. E. [2 ,6 ]
Stufkens, S. A. S. [3 ,6 ]
Wellenberg, R. H. H. [1 ,6 ]
Streekstra, G. J. [1 ,4 ,6 ]
Bus, S. A. [6 ]
Nieuwdorpe, M. [5 ,7 ]
Maas, M. [1 ,6 ]
机构
[1] Locat Univ Amsterdam, Amsterdam UMC, Radiol & Nucl Med, Meibergdreef 9, Amsterdam, Netherlands
[2] Locat Univ Amsterdam, Amsterdam UMC, Rehabil Med, Meibergdreef 9, Amsterdam, Netherlands
[3] Locat Univ Amsterdam, Amsterdam UMC, Orthopaed Surg, Meibergdreef 9, Amsterdam, Netherlands
[4] Locat Univ Amsterdam, Amsterdam UMC, Biomed Engn & Phys, Meibergdreef 9, Amsterdam, Netherlands
[5] Locat Univ Amsterdam, Amsterdam UMC, Internal Med, Meibergdreef 9, Amsterdam, Netherlands
[6] Amsterdam Movement Sci, Rehabil & Dev, Amsterdam, Netherlands
[7] Amsterdam Cardiovasc Sci, Diabet & Metab, Amsterdam, Netherlands
[8] Amsterdam UMC Locat AMC, Dept Radiol & Nucl Med, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
Diabetic foot; X-ray computed tomography; Adipose tissue; Diabetes mellitus; Pressure; CT; STIFFNESS;
D O I
10.1016/j.clinbiomech.2023.106126
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: This study assessed the use of dual-energy computed tomography (CT) to evaluate sub-calcaneal plantar fat pad changes in people with diabetic neuropathy.Methods: Dual-energy CT scans of people with diabetic neuropathy and non-diabetic controls were retrospectively included. Average CT values (in Hounsfield Units) and thickness (in centimeters) of the sub-calcaneal plantar fat pad were measured in mono-energetic images at two energy levels (40 keV and 70 keV). The CT values measured in patients with diabetic neuropathy were correlated to barefoot plantar pressure measurements performed during walking in a clinical setting.Findings: Forty-five dual-energy CT scans of people with diabetic neuropathy and eleven DECT scans of non-diabetic controls were included. Mean sub-calcaneal plantar fat pad thickness did not significantly differ be-tween groups (diabetes group 1.20 +/- 0.34 cm vs. control group 1.21 +/- 0.28 cm, P = 0.585). CT values at both 40 keV (-34.7 +/- 48.7 HU vs.-76.0 +/- 42.8 HU, P = 0.013) and 70 keV (-11.2 +/- 30.8 HU vs.-36.3 +/- 27.2 HU, P = 0.017) were significantly higher in the diabetes group compared to controls, thus contained less fatty tissue. This elevation was most apparent in patients with Type 1 diabetes. CT values positively correlated with the mean peak plantar pressure.Interpretation: Dual-energy CT was able to detect changes in the plantar fat pad of people with diabetic neuropathy.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Iodine Quantification Using Dual-Energy Computed Tomography for Differentiating Thymic Tumors
    Yan, Wei-Qiang
    Xin, Yong-Kang
    Jing, Yong
    Li, Gang-Feng
    Wang, Shu-Mei
    Rong, Wei-Cheng
    Xiao, Gang
    Lei, Xue-Bin
    Li, Bo
    Hu, Yu-Chuan
    Cui, Guang-Bin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 873 - 880
  • [32] Multi-material gap measurements using dual-energy computed tomography
    Jansson, Anton
    Hermanek, Petr
    Pejryd, Lars
    Carmignato, Simone
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2018, 54 : 420 - 426
  • [33] System-Independent Characterization of Materials Using Dual-Energy Computed Tomography
    Azevedo, Stephen G.
    Martz, Harry E., Jr.
    Aufderheide, Maurice B.
    Brown, William D.
    Champley, Kyle M.
    Kallman, Jeffrey S.
    Roberson, G. Patrick
    Schneberk, Daniel
    Seetho, Isaac M.
    Smith, Jerel A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 341 - 350
  • [34] Study of the Natural Crystalline Lens Characteristics Using Dual-Energy Computed Tomography
    Sachs, Jeffrey R.
    Nahmias, Javier A.
    Hiatt, Kevin D.
    Bomar, James G.
    West, Thomas G.
    Bunch, Paul M.
    Benayoun, Marc D.
    Lack, Chris
    Thompson, Atalie C.
    DIAGNOSTICS, 2022, 12 (11)
  • [35] Iodine mapping in brain tumor imaging using dual-energy computed tomography
    Mehndiratta, Amit
    Kapal, Jyoti M.
    Prabu, A.
    MEDICAL HYPOTHESES, 2011, 76 (05) : 764 - 764
  • [36] Myocardial perfusion imaging using dual-energy computed tomography: a clinical case
    Pontone, Gianluca
    Grancini, Luca
    Andreini, Daniele
    Pepi, Mauro
    Bartorelli, Antonio L.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (08) : 835 - 835
  • [37] A BEAM-HARDENING CORRECTION USING DUAL-ENERGY COMPUTED-TOMOGRAPHY
    COLEMAN, AJ
    SINCLAIR, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (11): : 1251 - 1256
  • [38] Diagnostic Role of Dual-Energy Computed Tomography in the Assessment of Musculoskeletal Oncology: A Literature Review
    Altwalah, Jumanah
    Alsalman, Hashim
    Sheikh, Adnan
    CURRENT RADIOLOGY REPORTS, 2024, 12 (03) : 19 - 29
  • [39] Dual-energy computed tomography versus magnetic resonance imaging for the assessment of iron overload
    Ibrahim, El-Sayed H.
    Bowman, Andrew W.
    Khalifa, Ayman M.
    2014 Middle East Conference on Biomedical Engineering (MECBME), 2014, : 5 - 8
  • [40] Diagnostic Role of Dual-Energy Computed Tomography in the Assessment of Musculoskeletal Oncology: A Literature Review
    Jumanah Altwalah
    Hashim Alsalman
    Adnan Sheikh
    Current Radiology Reports, 2024, 12 : 19 - 29