Sub-calcaneal plantar fat pad assessment using dual-energy computed tomography: First experience in the diabetic foot

被引:0
|
作者
Mens, M. A. [1 ,6 ,8 ]
Fassaert, T. F. [1 ,6 ]
Homan, J. H. [1 ,6 ]
Busch-Westbroek, T. E. [2 ,6 ]
Stufkens, S. A. S. [3 ,6 ]
Wellenberg, R. H. H. [1 ,6 ]
Streekstra, G. J. [1 ,4 ,6 ]
Bus, S. A. [6 ]
Nieuwdorpe, M. [5 ,7 ]
Maas, M. [1 ,6 ]
机构
[1] Locat Univ Amsterdam, Amsterdam UMC, Radiol & Nucl Med, Meibergdreef 9, Amsterdam, Netherlands
[2] Locat Univ Amsterdam, Amsterdam UMC, Rehabil Med, Meibergdreef 9, Amsterdam, Netherlands
[3] Locat Univ Amsterdam, Amsterdam UMC, Orthopaed Surg, Meibergdreef 9, Amsterdam, Netherlands
[4] Locat Univ Amsterdam, Amsterdam UMC, Biomed Engn & Phys, Meibergdreef 9, Amsterdam, Netherlands
[5] Locat Univ Amsterdam, Amsterdam UMC, Internal Med, Meibergdreef 9, Amsterdam, Netherlands
[6] Amsterdam Movement Sci, Rehabil & Dev, Amsterdam, Netherlands
[7] Amsterdam Cardiovasc Sci, Diabet & Metab, Amsterdam, Netherlands
[8] Amsterdam UMC Locat AMC, Dept Radiol & Nucl Med, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
Diabetic foot; X-ray computed tomography; Adipose tissue; Diabetes mellitus; Pressure; CT; STIFFNESS;
D O I
10.1016/j.clinbiomech.2023.106126
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: This study assessed the use of dual-energy computed tomography (CT) to evaluate sub-calcaneal plantar fat pad changes in people with diabetic neuropathy.Methods: Dual-energy CT scans of people with diabetic neuropathy and non-diabetic controls were retrospectively included. Average CT values (in Hounsfield Units) and thickness (in centimeters) of the sub-calcaneal plantar fat pad were measured in mono-energetic images at two energy levels (40 keV and 70 keV). The CT values measured in patients with diabetic neuropathy were correlated to barefoot plantar pressure measurements performed during walking in a clinical setting.Findings: Forty-five dual-energy CT scans of people with diabetic neuropathy and eleven DECT scans of non-diabetic controls were included. Mean sub-calcaneal plantar fat pad thickness did not significantly differ be-tween groups (diabetes group 1.20 +/- 0.34 cm vs. control group 1.21 +/- 0.28 cm, P = 0.585). CT values at both 40 keV (-34.7 +/- 48.7 HU vs.-76.0 +/- 42.8 HU, P = 0.013) and 70 keV (-11.2 +/- 30.8 HU vs.-36.3 +/- 27.2 HU, P = 0.017) were significantly higher in the diabetes group compared to controls, thus contained less fatty tissue. This elevation was most apparent in patients with Type 1 diabetes. CT values positively correlated with the mean peak plantar pressure.Interpretation: Dual-energy CT was able to detect changes in the plantar fat pad of people with diabetic neuropathy.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Dual-energy computed tomography as a lower radiation dose alternative to perfusion computed tomography in tumor viability assessment
    Zegadlo, Arkadiusz
    Rozyk, Aleksandra
    Zabicka, Magdalena
    Wiesik-Szewczyk, Ewa
    Maliborski, Artur
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [22] Dual-energy computed tomography as a lower radiation dose alternative to perfusion computed tomography in tumor viability assessment
    Arkadiusz Zegadło
    Aleksandra Różyk
    Magdalena Żabicka
    Ewa Więsik–Szewczyk
    Artur Maliborski
    Scientific Reports, 13
  • [23] Denoising algorithm for quantitative assessment of thoracic dual-energy computed tomography images
    Pienn, M.
    Bredies, K.
    Stollberger, R.
    Kovacs, G.
    Olschewski, A.
    Olschewski, H.
    Balint, Z.
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (19-20) : 815 - 815
  • [24] Accuracy analysis of intrahepatic fat density measurements using dual-energy computed tomography: Validation using a test phantom
    Arai, Tomohiro
    Misawa, Masaki
    Arai, Miki
    Shinozaki, Masafumi
    Sakamoto, Kayo
    Yajima, Yoshinobu
    Nozaki, Yuichi
    Tajima, Tsuyoshi
    Sato, Masanori
    Hinoshita, Fumihiko
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (03) : 403 - 415
  • [25] Assessment of the aggressiveness of rectal cancer using quantitative parameters derived from dual-energy computed tomography
    Li, Yi
    Li, Xubin
    Ren, Xiaoyi
    Ye, Zhaoxiang
    CLINICAL IMAGING, 2020, 68 : 136 - 142
  • [26] Methodological accuracy of image-based electron density assessment using dual-energy computed tomography
    Moehler, Christian
    Wohlfahrt, Patrick
    Richter, Christian
    Greilich, Steffen
    MEDICAL PHYSICS, 2017, 44 (06) : 2429 - 2437
  • [27] Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography
    Choi, ByukGyung
    Choi, In Young
    Cha, Sang Hoon
    Yeom, Suk Keu
    Chung, Hwan Hoon
    Lee, Seung Hwa
    Cha, Jaehyung
    Lee, Ju-Han
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (12) : 1179 - 1189
  • [28] Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography
    ByukGyung Choi
    In Young Choi
    Sang Hoon Cha
    Suk Keu Yeom
    Hwan Hoon Chung
    Seung Hwa Lee
    Jaehyung Cha
    Ju-Han Lee
    Japanese Journal of Radiology, 2020, 38 : 1179 - 1189
  • [29] Spectral Signal Density of Carotid Plaque Using Dual-Energy Computed Tomography
    Reynoso, Exequiel
    Rodriguez-Granillo, Gaston A.
    Capunay, Carlos
    Deviggiano, Alejandro
    Meli, Francisco
    Carrascosa, Patricia
    JOURNAL OF NEUROIMAGING, 2017, 27 (05) : 511 - 516
  • [30] USING DUAL-ENERGY COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF PERIPHERAL AND AXIAL GOUTY ARTHRITIS
    Butendieck, R.
    Parikh, P.
    Calamia, K.
    Persellin, S.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2011, 29 (01) : 206 - 206