Sub-calcaneal plantar fat pad assessment using dual-energy computed tomography: First experience in the diabetic foot

被引:0
|
作者
Mens, M. A. [1 ,6 ,8 ]
Fassaert, T. F. [1 ,6 ]
Homan, J. H. [1 ,6 ]
Busch-Westbroek, T. E. [2 ,6 ]
Stufkens, S. A. S. [3 ,6 ]
Wellenberg, R. H. H. [1 ,6 ]
Streekstra, G. J. [1 ,4 ,6 ]
Bus, S. A. [6 ]
Nieuwdorpe, M. [5 ,7 ]
Maas, M. [1 ,6 ]
机构
[1] Locat Univ Amsterdam, Amsterdam UMC, Radiol & Nucl Med, Meibergdreef 9, Amsterdam, Netherlands
[2] Locat Univ Amsterdam, Amsterdam UMC, Rehabil Med, Meibergdreef 9, Amsterdam, Netherlands
[3] Locat Univ Amsterdam, Amsterdam UMC, Orthopaed Surg, Meibergdreef 9, Amsterdam, Netherlands
[4] Locat Univ Amsterdam, Amsterdam UMC, Biomed Engn & Phys, Meibergdreef 9, Amsterdam, Netherlands
[5] Locat Univ Amsterdam, Amsterdam UMC, Internal Med, Meibergdreef 9, Amsterdam, Netherlands
[6] Amsterdam Movement Sci, Rehabil & Dev, Amsterdam, Netherlands
[7] Amsterdam Cardiovasc Sci, Diabet & Metab, Amsterdam, Netherlands
[8] Amsterdam UMC Locat AMC, Dept Radiol & Nucl Med, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
Diabetic foot; X-ray computed tomography; Adipose tissue; Diabetes mellitus; Pressure; CT; STIFFNESS;
D O I
10.1016/j.clinbiomech.2023.106126
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: This study assessed the use of dual-energy computed tomography (CT) to evaluate sub-calcaneal plantar fat pad changes in people with diabetic neuropathy.Methods: Dual-energy CT scans of people with diabetic neuropathy and non-diabetic controls were retrospectively included. Average CT values (in Hounsfield Units) and thickness (in centimeters) of the sub-calcaneal plantar fat pad were measured in mono-energetic images at two energy levels (40 keV and 70 keV). The CT values measured in patients with diabetic neuropathy were correlated to barefoot plantar pressure measurements performed during walking in a clinical setting.Findings: Forty-five dual-energy CT scans of people with diabetic neuropathy and eleven DECT scans of non-diabetic controls were included. Mean sub-calcaneal plantar fat pad thickness did not significantly differ be-tween groups (diabetes group 1.20 +/- 0.34 cm vs. control group 1.21 +/- 0.28 cm, P = 0.585). CT values at both 40 keV (-34.7 +/- 48.7 HU vs.-76.0 +/- 42.8 HU, P = 0.013) and 70 keV (-11.2 +/- 30.8 HU vs.-36.3 +/- 27.2 HU, P = 0.017) were significantly higher in the diabetes group compared to controls, thus contained less fatty tissue. This elevation was most apparent in patients with Type 1 diabetes. CT values positively correlated with the mean peak plantar pressure.Interpretation: Dual-energy CT was able to detect changes in the plantar fat pad of people with diabetic neuropathy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Changes in sub-calcaneal fat pad composition and their association with dynamic plantar foot pressure in people with diabetic neuropathy
    Bus, A. Sicco
    Akkerman, M. Erik
    Maas, Mario
    CLINICAL BIOMECHANICS, 2021, 88
  • [2] Initial experience with visualizing hand and foot tendons by dual-energy computed tomography
    Deng, Kai
    Sun, Cong
    Liu, Cheng
    Ma, Rui
    CLINICAL IMAGING, 2009, 33 (05) : 384 - 389
  • [3] Dual-Energy Computed Tomography for Stone Type Assessment: A Pilot Study of Dual-Energy Computed Tomography with Five Indices
    Rudenko, Vadim
    Serova, Natalia
    Kapanadze, Lida
    Taratkin, Mark
    Okhunov, Zhamshid
    Leonard, Stephen P.
    Ritter, Manuel
    Kriegmair, Maximilian
    Snurnitsyna, Olesya
    Kozlov, Vasiliy
    Laukhtina, Ekaterina
    Arshiev, Magomed
    Aleksandrova, Ksenia
    Salomon, Georg
    Enikeev, Dmitry
    Glybochko, Petr
    JOURNAL OF ENDOUROLOGY, 2020, 34 (09) : 893 - 899
  • [4] Quantification of the Fat Fraction in the Liver Using Dual-Energy Computed Tomography and Multimaterial Decomposition
    Hur, Bo Yun
    Lee, Jeong Min
    Hyunsik, Woo
    Lee, Kyung Bun
    Joo, Ijin
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 845 - 852
  • [5] Assessment of the diabetic foot using spiral computed tomography imaging and plantar pressure measurements: A technical report
    Smith, KE
    Commean, PK
    Mueller, MJ
    Robertson, DD
    Pilgram, T
    Johnson, J
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2000, 37 (01): : 31 - 40
  • [6] Plantar Plate Tear Diagnosis Using Dual-Energy Computed Tomography Collagen Material Decomposition Application
    Stevens, Christopher J.
    Murphy, Darra T.
    Korzan, Jeffrey R.
    Nicolaou, Savvas
    Munk, Peter L.
    Ouellette, Hugue
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 478 - 480
  • [7] Features of urate deposition in patients with gouty arthritis of the foot using dual-energy computed tomography
    Sun, Ying
    Ma, Lili
    Zhou, Yi
    Chen, Huiyong
    Ding, Yuqin
    Zhou, Jianjun
    Wei, Lei
    Zou, Hejian
    Jiang, Lindi
    INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2015, 18 (05) : 560 - 567
  • [8] The role of dual-energy computed tomography in the assessment of pulmonary function
    Hwang, Hye Jeon
    Hoffman, Eric A.
    Lee, Chang Hyun
    Goo, Jin Mo
    Levin, David L.
    Kauczor, Hans-Ulrich
    Seo, Joon Beom
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 320 - 334
  • [9] Xenon Ventilation Imaging Using Dual-Energy Computed Tomography in Asthmatics Initial Experience
    Chae, Eun Jin
    Seo, Joon Beom
    Lee, Jeongjin
    Kim, Namkug
    Goo, Hyun Woo
    Lee, Hyun Joo
    Lee, Choong Wook
    Ra, Seung Won
    Oh, Yeon-Mok
    Cho, You Sook
    INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 354 - 361
  • [10] Optimal Contrast of Computed Tomography Portal Venography Using Dual-Energy Computed Tomography
    Wang, Qi
    Shi, Gaofeng
    Liu, Xiang
    Wu, Runze
    Wang, Shijie