A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study

被引:3
|
作者
Shin, Hangsik [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Convergence Med, Coll Med, Seoul 05505, South Korea
关键词
blood pressure; continuous blood pressure; continuous pulse transit time; pulse transit time; pulse wave velocity;
D O I
10.1111/psyp.14173
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Unlike traditional pulse transit time (PTT), continuous PTT (CPTT) can be used to calculate PTT from all samples within the cardiac cycle. It has the potential to be utilized for continuous blood pressure (BP) estimation. This study evaluated the feasibility of CPTT as a non-invasive consecutive blood pressure estimation method in 20 volunteers. The CPTT was calculated with a time delay in all discrete samples of photoplethysmograms measured at two different body sites. BP was then calculated with a regression equation. For comparative evaluation, BP based on PTT was also estimated. Continuous blood pressure was measured using a non-invasive volume clamp BP monitoring device. Four types of BP measurement, systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and pulse pressure (PP), were estimated using PTT and CPTT. Correlation coefficients and root-mean-squared-error (RMSE) were used for evaluating BP estimation performance. For estimating SBP, DBP, PP, and MAP, PTT-based BP estimation showed correlations of .407, .373, .410, and .286, respectively, and CPTT-based BP estimation showed correlations of .436, .446, .506, and .097, respectively. With PTT-based estimation, the RMSE between the estimated BP and the baseline BP was 5.44 +/- 1.56 mmHg for SBP, 3.14 +/- 0.46 mmHg for DBP, 3.66 +/- 0.70 mmHg for MAP, and 3.73 +/- 1.31 mmHg for PP. The estimated BP using CPTT showed RMSE of 5.36 +/- 1.39 mmHg for SBP, 3.02 +/- 0.49 mmHg for SBP, 3.44 +/- 0.63 mmHg for MAP, and 3.91 +/- 1.41 mmHg for PP.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Portable Non-invasive Blood Pressure Measurement using Pulse Transmit Time
    Noche, Kaiser Josephus B.
    Flores Villaverde, Jocelyn
    Lazaro, Jose, Jr.
    2017 IEEE 9TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT AND MANAGEMENT (IEEE HNICEM), 2017,
  • [42] NEXFIN CONTINUOUS NON-INVASIVE ARTERIAL BLOOD PRESSURE VALIDATED WITH INVASIVE BLOOD PRESSURE
    Martina, J. R.
    Westerhof, B. E.
    van Goudoever, J.
    de Beaumont, E. M.
    Hollmann, M. W.
    Lahpor, J. R.
    de Mol, B. A.
    van Lieshout, J. J.
    JOURNAL OF HYPERTENSION, 2009, 27 : S192 - S192
  • [43] Continuous blood pressure measurement based on pulse transit time: a comparison to ambulatory blood pressure measurement
    Kuechler, G.
    Gehring, J.
    Wesely, M.
    Thimel, K.
    Haberl, R.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1267 - 1267
  • [44] Review of Photoplethysmography Based Non-invasive Continuous Blood Pressure Methods
    Tjahjadi, Hendrana
    Ramli, Kalamullah
    2017 15TH INTERNATIONAL CONFERENCE ON QUALITY IN RESEARCH (QIR) - INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND COMPUTER ENGINEERING, 2017, : 173 - 178
  • [45] Continuous Non-invasive Blood Pressure Monitoring Based on Applanation Tonometry
    Ariyadamrogkwan, Chollitha
    Chitsakul, Kitiphol
    Treetriluxana, Suradaj
    2014 FOURTH JOINT INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONIC AND ELECTRICAL ENGINEERING (JICTEE 2014), 2014,
  • [46] Clinical Study of Continuous Non-Invasive Blood Pressure Monitoring in Neonates
    Rao, Anoop
    Eskandar-Afshari, Fatima
    Weiner, Ya'el
    Billman, Elle
    McMillin, Alexandra
    Sella, Noa
    Roxlo, Thomas
    Liu, Junjun
    Leong, Weyland
    Helfenbein, Eric
    Walendowski, Alan
    Muir, Arthur
    Joseph, Alexandria
    Verma, Archana
    Ramamoorthy, Chandra
    Honkanen, Anita
    Green, Gabrielle
    Drake, Keith
    Govindan, Rathinaswamy B.
    Rhine, William
    Quan, Xina
    SENSORS, 2023, 23 (07)
  • [47] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [48] Pulse Transition Characterization from Electrocardiography and Photoplethysmography for Non-Invasive Blood Pressure Estimation
    Mohammed, Hazem
    Wu, Hao
    Wang, Guoxing
    2022 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 22), 2022, : 2841 - 2845
  • [49] A novel Blood Pressure estimation method combing Pulse Wave Transit Time model and neural network model
    Xu, Jun
    Jiang, Jiehui
    Zhou, Hucheng
    Yan, Zhuangzhi
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2130 - 2133
  • [50] Pulse waveform as an indicator of baseline offset in pulse transit time based blood pressure estimation
    Lin, Chen
    Zhou, Yuan
    Wang, Hu
    Wang, Yao
    2017 IEEE-NIH HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2017, : 26 - 31