A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study

被引:3
|
作者
Shin, Hangsik [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Convergence Med, Coll Med, Seoul 05505, South Korea
关键词
blood pressure; continuous blood pressure; continuous pulse transit time; pulse transit time; pulse wave velocity;
D O I
10.1111/psyp.14173
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Unlike traditional pulse transit time (PTT), continuous PTT (CPTT) can be used to calculate PTT from all samples within the cardiac cycle. It has the potential to be utilized for continuous blood pressure (BP) estimation. This study evaluated the feasibility of CPTT as a non-invasive consecutive blood pressure estimation method in 20 volunteers. The CPTT was calculated with a time delay in all discrete samples of photoplethysmograms measured at two different body sites. BP was then calculated with a regression equation. For comparative evaluation, BP based on PTT was also estimated. Continuous blood pressure was measured using a non-invasive volume clamp BP monitoring device. Four types of BP measurement, systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and pulse pressure (PP), were estimated using PTT and CPTT. Correlation coefficients and root-mean-squared-error (RMSE) were used for evaluating BP estimation performance. For estimating SBP, DBP, PP, and MAP, PTT-based BP estimation showed correlations of .407, .373, .410, and .286, respectively, and CPTT-based BP estimation showed correlations of .436, .446, .506, and .097, respectively. With PTT-based estimation, the RMSE between the estimated BP and the baseline BP was 5.44 +/- 1.56 mmHg for SBP, 3.14 +/- 0.46 mmHg for DBP, 3.66 +/- 0.70 mmHg for MAP, and 3.73 +/- 1.31 mmHg for PP. The estimated BP using CPTT showed RMSE of 5.36 +/- 1.39 mmHg for SBP, 3.02 +/- 0.49 mmHg for SBP, 3.44 +/- 0.63 mmHg for MAP, and 3.91 +/- 1.41 mmHg for PP.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Noninvasive Continuous Blood Pressure Estimation with Peripheral Pulse Transit Time
    Li, Yibin
    Chen, Xiaomeng
    Zhang, Yang
    Deng, Ning
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 66 - 69
  • [22] A Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning
    Chen, Shuo
    Ji, Zhong
    Wu, Haiyan
    Xu, Yingchao
    SENSORS, 2019, 19 (11)
  • [23] Validation of Pulse Transit Time-Based Blood pressure measurement in heart failure Patients with non-invasive Ventilation
    Spiesshoefer, J.
    Heinrich, J.
    Eckert, S.
    Bitter, T.
    Horstkotte, D.
    Oldenburg, O.
    INTERNIST, 2013, 54 : 106 - 106
  • [24] Blood Pressure Estimation Based on Pulse Transit Time with LANDMARC
    Wang, Yang
    Liu, Zhiwen
    2017 IEEE LIFE SCIENCES CONFERENCE (LSC), 2017, : 141 - 144
  • [25] Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective observational study
    Raju, Reenu
    Isac, Mathai
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2022, 11 (06) : 2685 - 2689
  • [26] Introduction of Boosting Algorithms in Continuous Non-Invasive Cuff-less Blood Pressure Estimation using Pulse Arrival Time
    Ghosh, Aayushman
    Chatterjee, Tamaghno
    Sarkar, Sayan
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5429 - 5432
  • [27] Verification of a non-invasive continuous cardiac output measurement method based on the pulse-contour analysis combined with pulse wave transit time
    Yamada, T.
    Sugo, Y.
    Takeda, J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 57 - 57
  • [28] A non-invasive pulse pressure method for the estimation of total arterial compliance
    Segers, P
    Stergiopulos, N
    Verdonck, P
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 171 - 174
  • [29] Research on the non-invasive continuous blood pressure monitoring models cluster based on pulse wave
    Wu H.
    Ji Z.
    Li M.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (07): : 224 - 234
  • [30] Continuous non-invasive determination of nocturnal blood pressure variation using photoplethysmographic pulse wave signals: comparison of pulse propagation time, pulse transit time and RR-interval
    Fischer, Christoph
    Penzel, Thomas
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (01)