Effect of Tube Voltage and Radiation Dose on Image Quality in Pediatric Abdominal CT Using Deep Learning Reconstruction: A Phantom Study

被引:1
|
作者
Kim, Daehong [1 ]
Jeon, Pil-Hyun [2 ]
Lee, Chang-Lae [3 ]
Chung, Myung-Ae [4 ]
机构
[1] Eulji Univ, Dept Radiol Sci, Seongnam 13135, South Korea
[2] Wonju Severance Christian Hosp, Dept Radiol, Wonju 26426, South Korea
[3] Samsung Elect, Hlth & Med Equipment Business Unit, Suwon 16677, South Korea
[4] Eulji Univ, Dept Bigdata Med Convergence, Seongnam 13135, South Korea
来源
SYMMETRY-BASEL | 2023年 / 15卷 / 02期
关键词
tube voltage; radiation dose; image quality; pediatric computed tomography (CT); deep learning reconstruction (DLR); ALGORITHM; REDUCTION;
D O I
10.3390/sym15020501
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Children have a potential risk from radiation exposure because they are more sensitive to radiation than adults. Objective: The purpose of this work is to estimate image quality according to tube voltage (kV) and radiation dose in pediatric computed tomography (CT) using deep learning reconstruction (DLR). Methods: Phantom images of children and adults were obtained for kV, radiation dose, and image reconstruction methods. The CT emits a fan beam to the opposite detector, and the geometry of the detector was symmetrical. Phantom images of children and adults were acquired at a volume CT dose index (CTDIvol) from 0.5 to 10.0 mGy for tube voltages at 80, 100, and 120 kV. A DLR was used to reconstruct the phantom image, and filtered back projection (FBP) and iterative reconstruction (IR) were also performed for comparison with the DLR. Image quality was evaluated by measuring the contrast-to-noise ratio (CNR) and noise. Results: Under the same imaging conditions, the DLR images of pediatric and adult phantoms generally provided improved CNR and noise compared with the FBP and IR images. At a similar CNR and noise, the FBP, IR, and DLR of the pediatric images showed a dose reduction compared with the FBP, IR, and DLR of the adult images, respectively. In terms of the effect of tube voltage, the CNR of the 100 kV DLR images was higher than that of the 120 kV DLR images. Conclusion: According to the results, since pediatric CT images maintain the same image quality at lower doses compared with adult CT images, DLR can improve image quality while reducing the radiation dose in children's abdominal CT scans.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Successful Dose Reduction Using Reduced Tube Voltage With Hybrid Iterative Reconstruction in Pediatric Abdominal CT
    Berlin, Sheila C.
    Weinert, Dayna M.
    Vasavada, Pauravi S.
    Martinez-Rios, Claudia
    Parikh, Roshni A.
    Wien, Michael A.
    Jordan, David W.
    Novak, Ronald D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : 392 - 399
  • [32] Effect of a new deep learning image reconstruction algorithm for abdominal computed tomography imaging on image quality and dose reduction compared with two iterative reconstruction algorithms: a phantom study
    Greffier, Joel
    Dabli, Djamel
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Frandon, Julien
    Beregi, Jean-Paul
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 229 - +
  • [33] Reducing the radiation dose of pediatric paranasal sinus CT using an ultralow tube voltage (70 kVp) combined with iterative reconstruction Feasibility and image quality
    Chi, Jing
    Xu, Dongfeng
    Yin, Shengnan
    Li, Man
    Shen, Li
    Ding, Ning
    Chen, Xiaofang
    Ji, Yiding
    [J]. MEDICINE, 2020, 99 (34) : E21886
  • [34] Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Lee, Jeong Min
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    [J]. CURRENT MEDICAL IMAGING, 2024, 20
  • [35] Image Quality Improvement of Low-dose Abdominal CT Using Deep Learning Image Reconstruction Compared With the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Min Lee, Jeong
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    [J]. Current Medical Imaging, 2024, 20
  • [36] Effect of X-ray Tube Parameters and Iodine Concentration on Image Quality and Radiation Dose in Cerebral Pediatric and Adult CT Angiography A Phantom Study
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Raissaki, Maria
    Damilakis, John
    [J]. INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 192 - 199
  • [37] The impact of ASiR-V on abdominal CT radiation dose and image quality-A phantom study
    Morup, Svea Deppe
    Stowe, John
    Kusk, Martin Weber
    Precht, Helle
    Foley, Shane
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (03) : 453 - 459
  • [38] A feasibility study of realizing low-dose abdominal CT using deep learning image reconstruction algorithm
    Li, Lu-Lu
    Wang, Huang
    Song, Jian
    Shang, Jin
    Zhao, Xiao-Ying
    Liu, Bin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (02) : 361 - 372
  • [39] Impact of an artificial intelligence deep-learning reconstruction algorithm for CT on image quality and potential dose reduction: A phantom study
    Greffier, Joel
    Si-Mohamed, Salim
    Frandon, Julien
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5052 - 5063
  • [40] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    [J]. RADIOGRAPHICS, 2018, 38 (05) : 1421 - +