Real-time Element Position Tracking of Flexible Array Transducer for Ultrasound Beamforming

被引:6
|
作者
China, D. [1 ]
Feng, Z. [2 ,3 ]
Hooshangnejad, H. [1 ,2 ]
Sforza, D. [2 ]
Vagdargi, P. [1 ]
Bell, M. A. L. [1 ,3 ]
Uneri, A. [1 ]
Ding, K. [2 ]
机构
[1] Johns Hopkins Sch Med, Dept Biomed Engn, Baltimore, MD USA
[2] Johns Hopkins Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD USA
来源
MEDICAL IMAGING 2023 | 2023年 / 12470卷
基金
美国国家卫生研究院;
关键词
Flexible array transducer; ultrasound imaging; ultrasound beamforming; surface geometry estimation; image-guided radiotherapy; ABSORBABLE RADIOPAQUE HYDROGEL; RADIATION-THERAPY; SPACER; IMAGE; HEAD;
D O I
10.1117/12.2654435
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Unlike traditional ultrasound (US) transducers with rigid casing, flexible array transducers can be deformed to patient-specific geometries, thus potentially removing user dependence during real-time monitoring in radiotherapy. Proper transducer geometry estimation is required for the transducer's delay-and-sum (DAS) beamforming algorithm to reconstruct B-mode US images. The main contribution of this work is to track each element's position of the transducer to improve the quality of reconstructed images. An NDI Polaris Spectra infrared tracker was used to localize the custom design optical markers and interfaced using the Plus toolkit to estimate the transducer geometry in real-time. Each marker was localized with respect to a reference marker. Each element's coordinate position and azimuth angle were estimated using a polygon fitting algorithm. Finally, DAS was used to reconstruct the US image from radio-frequency channel data. Various transducer curvatures were emulated using gel padding placed on a CIRS phantom. The geometric accuracy of localizing the optical markers attached to the transducer surface was evaluated using 3D Cone-Beam Computed Tomography (CBCT). The tracked element positions' deviations compared to the CBCT images were measured to be 0.50 +/- 0.29 mm. The Dice score for the segmented target structure from reconstructed US images was 95.1 +/- 3.3% for above mentioned error in element position. We have obtained a high accuracy (<1mm error) when tracking the element positions with different random curvatures. The proposed method can be used for reconstructing US images to assist in real-time monitoring of radiotherapy, with minimal user dependence.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Real-Time Localization of OPMs in a Flexible Array During MEG Recordings
    Gu, Wenyu
    He, Kaiyan
    Ma, Xiao
    Li, Dongxu
    Pang, Wei
    Sheng, Jingwei
    Gao, Jia-Hong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 10
  • [42] The Element by Element Acoustic Power Measurement of Ultrasound Array Transducer for Sonographic Instrument
    Yun, Y. H.
    Jho, M. J.
    Kim, Y. T.
    Lee, M. H.
    Eun, H. J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1609 - +
  • [43] Real-time trajectory tracking control of a parallel robot with flexible links
    Morlock, Merlin
    Meyer, Niklas
    Pick, Marc-André
    Seifried, Robert
    Mechanism and Machine Theory, 2021, 158
  • [44] Real-time trajectory tracking control of a parallel robot with flexible links
    Morlock, Merlin
    Meyer, Niklas
    Pick, Marc-Andre
    Seifried, Robert
    MECHANISM AND MACHINE THEORY, 2021, 158
  • [45] Real-time tracking of liver motion and deformation using a flexible needle
    Lei, Peng
    Moeslein, Fred
    Wood, Bradford J.
    Shekhar, Raj
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2011, 6 (03) : 435 - 446
  • [46] IN VIVO COMPARISON OF REAL-TIME TRACKING ALGORITHMS FOR INTERVENTIONAL FLEXIBLE ENDOSCOPY
    Masson, N.
    Nageotte, Fl.
    Zanne, Ph.
    de Mathelin, M.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 1350 - 1353
  • [47] Real-time tracking of liver motion and deformation using a flexible needle
    Peng Lei
    Fred Moeslein
    Bradford J. Wood
    Raj Shekhar
    International Journal of Computer Assisted Radiology and Surgery, 2011, 6 : 435 - 446
  • [48] Real-time beamforming using high-speed FPGAs at the Allen Telescope Array
    Barott, William C.
    Milgrome, Oren
    Wright, Melvyn
    MacMahon, David
    Kilsdonk, Tom
    Backus, Peter
    Dexter, Matt
    RADIO SCIENCE, 2011, 46
  • [49] Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging
    Nam, Seung Yun
    Emelianov, Stanislav Y.
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2014, 18 (02) : 151 - 155
  • [50] Real-time ultrasound transmission imaging: Evaluation of a novel hybrid array
    Merritt, CR
    Forsberg, F
    Schultz, SM
    RADIOLOGY, 2000, 217 : 343 - 343