Real-time Element Position Tracking of Flexible Array Transducer for Ultrasound Beamforming

被引:6
|
作者
China, D. [1 ]
Feng, Z. [2 ,3 ]
Hooshangnejad, H. [1 ,2 ]
Sforza, D. [2 ]
Vagdargi, P. [1 ]
Bell, M. A. L. [1 ,3 ]
Uneri, A. [1 ]
Ding, K. [2 ]
机构
[1] Johns Hopkins Sch Med, Dept Biomed Engn, Baltimore, MD USA
[2] Johns Hopkins Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD USA
来源
MEDICAL IMAGING 2023 | 2023年 / 12470卷
基金
美国国家卫生研究院;
关键词
Flexible array transducer; ultrasound imaging; ultrasound beamforming; surface geometry estimation; image-guided radiotherapy; ABSORBABLE RADIOPAQUE HYDROGEL; RADIATION-THERAPY; SPACER; IMAGE; HEAD;
D O I
10.1117/12.2654435
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Unlike traditional ultrasound (US) transducers with rigid casing, flexible array transducers can be deformed to patient-specific geometries, thus potentially removing user dependence during real-time monitoring in radiotherapy. Proper transducer geometry estimation is required for the transducer's delay-and-sum (DAS) beamforming algorithm to reconstruct B-mode US images. The main contribution of this work is to track each element's position of the transducer to improve the quality of reconstructed images. An NDI Polaris Spectra infrared tracker was used to localize the custom design optical markers and interfaced using the Plus toolkit to estimate the transducer geometry in real-time. Each marker was localized with respect to a reference marker. Each element's coordinate position and azimuth angle were estimated using a polygon fitting algorithm. Finally, DAS was used to reconstruct the US image from radio-frequency channel data. Various transducer curvatures were emulated using gel padding placed on a CIRS phantom. The geometric accuracy of localizing the optical markers attached to the transducer surface was evaluated using 3D Cone-Beam Computed Tomography (CBCT). The tracked element positions' deviations compared to the CBCT images were measured to be 0.50 +/- 0.29 mm. The Dice score for the segmented target structure from reconstructed US images was 95.1 +/- 3.3% for above mentioned error in element position. We have obtained a high accuracy (<1mm error) when tracking the element positions with different random curvatures. The proposed method can be used for reconstructing US images to assist in real-time monitoring of radiotherapy, with minimal user dependence.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Real-time 3D ultrasound with multiple transducer arrays
    Fronheiser, MP
    Light, ED
    Smith, SW
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 786 - 789
  • [22] Real-time, 3-D ultrasound with multiple transducer arrays
    Fronheiser, MP
    Light, ED
    Idriss, SF
    Wolf, PD
    Smith, SW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) : 100 - 105
  • [24] A real-time array calibration method for underwater acoustic flexible sensor array
    An, Liang
    Chen, Lijun
    APPLIED ACOUSTICS, 2015, 97 : 54 - 64
  • [25] Real-Time Three-Dimensional Flexible Needle Tracking using Two-Dimensional Ultrasound
    Vrooijink, Gustaaf J.
    Abayazid, Momen
    Misra, Sarthak
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 1688 - 1693
  • [26] A New Real-time Position and Orientation Tracking System for Endoscopy
    Liu, Likun
    Ouyang, Zizi
    Wang, Sen
    Wang, Yi
    Chen, Xiaodong
    Yu, Daoyin
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 1196 - 1199
  • [27] Phased-Array 64-Element 20-MHz Receiver For Data Capture and Real-Time Beamforming
    Black, Richard A.
    Brady, Jay M.
    Jeffs, Brian D.
    Diao, Junming
    Warnick, Karl F.
    2016 UNITED STATES NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2016,
  • [28] Flexible real-time linux:: A flexible hard real-time environment
    Terrasa, A
    García-Fornes, A
    Botti, VJ
    REAL-TIME SYSTEMS, 2002, 22 (1-2) : 151 - 173
  • [29] Flexible Real-Time Linux*: A Flexible Hard Real-Time Environment
    Andrés Terrasa
    Ana García-Fornes
    Vicente J. Botti
    Real-Time Systems, 2002, 22 : 151 - 173
  • [30] Real-time vessel segmentation and tracking for ultrasound imaging applications
    Guerrero, Julian
    Salcudean, Septimiu E.
    McEwen, James A.
    Masri, Bassarn A.
    Nicolaou, Savvakis
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (08) : 1079 - 1090