Real-time Element Position Tracking of Flexible Array Transducer for Ultrasound Beamforming

被引:6
|
作者
China, D. [1 ]
Feng, Z. [2 ,3 ]
Hooshangnejad, H. [1 ,2 ]
Sforza, D. [2 ]
Vagdargi, P. [1 ]
Bell, M. A. L. [1 ,3 ]
Uneri, A. [1 ]
Ding, K. [2 ]
机构
[1] Johns Hopkins Sch Med, Dept Biomed Engn, Baltimore, MD USA
[2] Johns Hopkins Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD USA
来源
MEDICAL IMAGING 2023 | 2023年 / 12470卷
基金
美国国家卫生研究院;
关键词
Flexible array transducer; ultrasound imaging; ultrasound beamforming; surface geometry estimation; image-guided radiotherapy; ABSORBABLE RADIOPAQUE HYDROGEL; RADIATION-THERAPY; SPACER; IMAGE; HEAD;
D O I
10.1117/12.2654435
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Unlike traditional ultrasound (US) transducers with rigid casing, flexible array transducers can be deformed to patient-specific geometries, thus potentially removing user dependence during real-time monitoring in radiotherapy. Proper transducer geometry estimation is required for the transducer's delay-and-sum (DAS) beamforming algorithm to reconstruct B-mode US images. The main contribution of this work is to track each element's position of the transducer to improve the quality of reconstructed images. An NDI Polaris Spectra infrared tracker was used to localize the custom design optical markers and interfaced using the Plus toolkit to estimate the transducer geometry in real-time. Each marker was localized with respect to a reference marker. Each element's coordinate position and azimuth angle were estimated using a polygon fitting algorithm. Finally, DAS was used to reconstruct the US image from radio-frequency channel data. Various transducer curvatures were emulated using gel padding placed on a CIRS phantom. The geometric accuracy of localizing the optical markers attached to the transducer surface was evaluated using 3D Cone-Beam Computed Tomography (CBCT). The tracked element positions' deviations compared to the CBCT images were measured to be 0.50 +/- 0.29 mm. The Dice score for the segmented target structure from reconstructed US images was 95.1 +/- 3.3% for above mentioned error in element position. We have obtained a high accuracy (<1mm error) when tracking the element positions with different random curvatures. The proposed method can be used for reconstructing US images to assist in real-time monitoring of radiotherapy, with minimal user dependence.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Deep Learning for Ultrasound Beamforming in Flexible Array Transducer
    Huang, Xinyue
    Bell, Muyinatu A. Lediju
    Ding, Kai
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (11) : 3178 - 3189
  • [2] Real-time 3-D intracranial ultrasound with an endoscopic matrix array transducer
    Light, Edward D.
    Mukundan, Srinivasan
    Wolf, Patrick D.
    Smith, Stephen W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (08): : 1277 - 1284
  • [3] Real-time photoacoustic imaging based on multi-element linear transducer array
    Yin, BZ
    Xing, D
    Wang, Y
    Zeng, YG
    Tan, Y
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 105 - 113
  • [4] Boundary Array Transducer and Beamforming for Low-Cost Real-time 3D Imaging
    Yen, Jesse T.
    Powis, Emily
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [5] A Flexible Ultrasound Transducer Array Patch
    Zhang, Wenjie
    Ma, Tiancheng
    Han, Liuyang
    Zhao, Liuyan
    Liu, Jie
    Dong, Ying
    Wang, Xiaohao
    25TH ANNUAL CONFERENCE & 14TH INTERNATIONAL CONFERENCE OF THE CHINESE SOCIETY OF MICRO-NANO TECHNOLOGY, CSMNT 2023, 2024, 2740
  • [6] Preliminary work of real-time ultrasound imaging system for 2-D array transducer
    Li, Xu
    Yang, Jiali
    Ding, Mingyue
    Yuchi, Ming
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1579 - S1585
  • [7] Real-time image tracking of a flexible bronchoscope
    Schneider, A
    Hautmann, H
    Barfuss, H
    Pinkau, T
    Peltz, F
    Feussner, H
    Wichert, A
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 753 - 757
  • [8] Real-time Beamforming Testbed and Tracking Relay for mmWave Applications
    Bisulli, Lorenzo
    Scazzoli, Davide
    Linsalata, Francesco
    Magarini, Maurizio
    Mizmizi, Marouan
    Mazzucco, Christian
    Spagnolini, Umberto
    2024 IEEE 30TH INTERNATIONAL CONFERENCE ON EMBEDDED AND REAL-TIME COMPUTING SYSTEMS AND APPLICATIONS, RTCSA 2024, 2024, : 114 - 119
  • [9] A two-dimensional transducer array for real-time 3D medical ultrasound imaging
    Bureau, JM
    Steichen, W
    Lebail, G
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1065 - 1068
  • [10] Real-time imaging for patient position alignment and tracking
    Murphy, MJ
    IMAGING IN RADIATION THERAPY, 1998, (24): : 237 - 258