A Universal Device to Convert a Continuous Flow Assist Device to a Pulsatile Flow Device to Simulate Normal Blood Flow and Pressure Patterns

被引:0
|
作者
Gerrah, Rabin [1 ]
机构
[1] Stanford Univ, Dept Cardiothorac Surg, CVRB Falk Bldg,300 Pasteur Dr, Stanford, CA 94305 USA
关键词
assist devices; pulsatility; cardiovascular; hemodynamics;
D O I
10.1177/15533506221140534
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundContinuous follow assist devices (CFAD) are the most commonly used mechanical circulatory support devices. Compared to Pulsatile flow assist devices (PFAD), CFADs deliver a non-physiologic type of flow, which might contribute to complications related to lack of pulsatility in these devices. Moreover, lack of pulsatility complicates the clinical management of these patients who often present with good perfusion but with no palpable pulse and none or a negligible pulse pressure on blood pressure measurement.Methods and resultsPresented here is a concept of a universal converter device that can be added inline other CFADs to convert the flow from continuous to pulsatile, simulating a normal flow and pressure pattern. After initial implantation and stabilization with a CFAD, adding this converter might potentially provide the benefits of pulsatile physiologic flow. The device is made of 2 components connected in parallel, working in tandem in user determined cycles. The continuous flow through a specifically positioned openings create a smooth conversion to a pulsatile flow. This device can convert a continuous flow to a physiologic pulsatile flow to achieve a native-like flow pattern and potentially prevent some CFAD complications.ConclusionThis paper presents the concept of pulsatility generation and simulation for other assist devices. Such a device can be a universal add-on or a supplemental option for CFADs.
引用
收藏
页码:471 / 476
页数:6
相关论文
共 50 条
  • [41] Cerebral Blood Flow Autoregulation Is Preserved After Continuous-Flow Left Ventricular Assist Device Implantation
    Ono, Masahiro
    Joshi, Brijen
    Brady, Kenneth
    Easley, R. Blaine
    Kibler, Kathy
    Conte, John
    Shah, Ashish
    Russell, Stuart D.
    Hogue, Charles W.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (06) : 1022 - 1028
  • [42] A SIMPLE DEVICE FOR CHANGING NON-PULSATILE INTO PULSATILE BLOOD-FLOW
    GEORGESCU, H
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1982, 5 (05): : 325 - 326
  • [43] Blood Flow and Pressure Evaluation for a Pulsatile Conduit-Shaped Ventricular Assist Device with Structural Characteristic of Conduit Shape
    Kang, Seong Min
    Choi, Seong Wook
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2011, 35 (11) : 1191 - 1198
  • [44] A Single Center Experience of Device Exchange for Continuous Flow Left Ventricular Assist Device Thrombosis
    Morine, K. J.
    Mehak, D.
    Upshaw, J. N.
    Pham, D. T.
    Kapur, N. K.
    Vest, A. R.
    DeNofrio, D.
    Kiernan, M. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S251 - S251
  • [45] Intrathoracic implantation of a continuous flow left ventricular assist device - the microdiagonal blood pump
    Christiansen, S.
    Redmann, K.
    Autschbach, R.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2006, 47 (03): : 329 - 335
  • [46] Pulsatile operation of a continuous-flow right ventricular assist device (RVAD) to improve vascular pulsatility
    Ng, Boon C.
    Kleinheyer, Matthias
    Smith, Peter A.
    Timms, Daniel
    Cohn, William E.
    Lim, Einly
    PLOS ONE, 2018, 13 (04):
  • [47] Long Term Left Ventricular Assist Device Therapy: Renal Response to Pulsatile vs Continuous Flow
    Sajgalik, Pavol
    Soon, Park J.
    Edwards, Brooks S.
    Kuswaha, Sudrih
    Daly, Richard
    Joyce, Lyle D.
    Nemec, Peter
    Kara, Tomas
    Brunett, John C.
    Boilson, Barry
    Chen, Horng
    Schirger, John A.
    CIRCULATION, 2012, 126 (21)
  • [48] The Lavare Cycle: A Novel Pulsatile Feature of the HVAD Continuous-Flow Left Ventricular Assist Device
    Kumar, Julia
    Elhassan, Amir
    Dimitrova, Galina
    Essandoh, Michael
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (04) : 1170 - 1171
  • [49] Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device
    Day, SW
    McDaniel, JC
    Wood, HG
    Allaire, PE
    Landrot, N
    Curtas, A
    ASAIO JOURNAL, 2001, 47 (04) : 406 - 411
  • [50] Comparison of Outcomes for Heart Transplantation Following Continuous Versus Pulsatile Flow Ventricular Assist Device Bridging
    Kilic, A.
    Conte, J. V.
    Yuh, D. D.
    Shah, A. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S88 - S88