Planning CT Identifies Patients at Risk of High Prostate Intrafraction Motion

被引:1
|
作者
Ballhausen, Hendrik [1 ]
Li, Minglun [1 ]
Lombardo, Elia [1 ]
Landry, Guillaume [1 ]
Belka, Claus [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Radiat Oncol, D-81377 Munich, Germany
关键词
radiation oncology; external beam radiotherapy; prostate carcinoma; intrafraction motion; motion management; risk management; planning CT; IMAGE-GUIDED RADIOTHERAPY; BEAM RADIATION-THERAPY; REAL-TIME; ENDORECTAL BALLOON; SYSTEM; MODEL;
D O I
10.3390/cancers15164103
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Prostate motion (standard deviation, range of motion, and diffusion coefficient) was calculated from 4D ultrasound data of 1791 fractions of radiation therapy in N = 100 patients. The inner diameter of the lesser pelvis was obtained from transversal slices through the pubic symphysis in planning CTs. On the lateral and craniocaudal axes, motility increases significantly (t-test, p < 0.005) with the inner diameter of the lesser pelvis. A diameter of > 106 mm (ca. 6th decile) is a good predictor for high prostate intrafraction motion (ca. 9th decile). The corresponding area under the receiver operator curve (AUROC) is 80% in the lateral direction, 68% to 80% in the craniocaudal direction, and 62% to 70% in the vertical direction. On the lateral x-axis, the proposed test is 100% sensitive and has a 100% negative predictive value for all three characteristics (standard deviation, range of motion, and diffusion coefficient). On the craniocaudal z-axis, the proposed test is 79% to 100% sensitive and reaches 95% to 100% negative predictive value. On the vertical axis, the proposed test still delivers 98% negative predictive value but is not particularly sensitive. Overall, the proposed predictor is able to help identify patients at risk of high prostate motion based on a single planning CT.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Intrafraction Prostate Motion Management for Ultra-Hypofractionated Radiotherapy of Prostate Cancer
    Oehler, Christoph
    Roehner, Nina
    Sumila, Marcin
    Curschmann, Juergen
    Storelli, Fabrizio
    Zwahlen, Daniel Rudolf
    Schneider, Uwe
    CURRENT ONCOLOGY, 2022, 29 (09) : 6314 - 6324
  • [22] Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods
    Beltran, Chris.
    Herman, Michael G.
    Davis, Brian J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 289 - 295
  • [23] Quantification of intrafraction prostate motion and its dosimetric effect on VMAT
    Prabhjot Juneja
    Emma Colvill
    Andrew Kneebone
    Thomas Eade
    Jin A. Ng
    David I. Thwaites
    Paul Keall
    Ramandeep Kaur
    Per Poulsen
    Jeremy T. Booth
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 317 - 324
  • [24] Direct measurement of prostate intrafraction motion and residual setup error
    Adamson, J. D.
    Wu, Q.
    Yan, D.
    Ghilezan, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S549 - S549
  • [25] Do Interventions for Prostate Cancer Intrafraction Motion Make a Difference?
    Parikh, P. J.
    Olsen, J. R.
    Smith, R. L.
    Noel, C.
    Khan, D.
    Tropper, S.
    Mantz, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S591 - S591
  • [26] DOSIMETRIC EVALUATION OF MARGIN REDUCTION AND INTRAFRACTION MOTION FOR PROSTATE SBRT
    Jiang, L.
    Li, H.
    Boike, T.
    Heinzerling, J.
    Solberg, T.
    Foster, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S193 - S194
  • [27] Dosimetric Evaluation of PTV Margins and Intrafraction Motion for Prostate SBRT
    Jiang, L.
    Li, H.
    Heinzerling, J.
    Boike, T.
    Solberg, T.
    Foster, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] Optimizing KV Fluoro Acquisition for Prostate Intrafraction Motion Evaluation
    Adamson, J.
    Wu, Q.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [29] Quantification of intrafraction prostate motion and its dosimetric effect on VMAT
    Juneja, Prabhjot
    Colvill, Emma
    Kneebone, Andrew
    Eade, Thomas
    Ng, Jin A.
    Thwaites, David I.
    Keall, Paul
    Kaur, Ramandeep
    Poulsen, Per
    Booth, Jeremy T.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (02) : 317 - 324
  • [30] THE INFLUENCE OF A DIET ON THE INTRAFRACTION MOTION DURING IMRT FOR PROSTATE CANCER
    Lips, I.
    Moman, M.
    Kotte, A.
    van der Heide, U.
    van Vulpen, M.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S87 - S87