Extending the Eclipse™ AcurosXB output factor table for small field radiosurgery

被引:1
|
作者
Wu, Ning Genevieve [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR USA
[2] Oregon Hlth & Sci Univ, Dept Radiat Med, 3720 S Bond Ave,unit 712, Portland, OR 97239 USA
来源
关键词
Eclipse small field dosimetry; Small Field Output Factor Measurement;
D O I
10.1002/acm2.13877
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the necessity of extending the output factor table (OF Table) of the Varian Eclipse (TM) Treatment Planning System for small field stereotactic radiosurgery (SRS) and stereotactic body radiosurgery (SBRT) treatments. Methods: A new AcurosXB 15.6 beam model was created in the Eclipse Beam Configuration, which is identical to the one that has been used in the clinic with a default 3 x 3 cm to 40 x 40 cm OF Table, except the OF Table in the new model was extended to cover the range from 1 x 1 cm to 40 x 40 cm. 80 small square and rectangular output factors were measured on a Varian TrueBeam utilizing a Standard Imaging Exradin W2-1x1 scintillator detector, inside a PTW BeamScan water tank with 95 cm SSD at 5 cm depth. Cerenkov contamination was corrected using a rectangular field method (2 cm x 15 cm field). Nine Radiosurgery plans with primary jaw setting ranging from 0.7 cm to 2.0 cm were evaluated by both beam models. The monitor unit (MU) differences between the two beam models were calculated for identical 3-dimensional (3D) absolute dose distributions. Output factors, measured versus Eclipse calculated, were compared down to 0.5 x 0.5 cm primary jaw setting. Results: For the 6FFF beam, the difference between the two beam models was similar to 6% for 1 x 1 cm jaw settings and 4% at 1.5 x 1.5 cm, with the extended OF Table requiring higher MUs for the same dose prescription and same 3-dimensional isodose distribution. For the 6MV beam, the corresponding difference is similar to 7.5% for 1 x 1 cm, 5% for 1.5 x 1.5 cm, and 3% for 2 x 2 cm jaw settings, with the extended OF Table requiring higher MUs. For jaw settings smaller than 1 x 1 cm, measured dose can be considerably smaller than Eclipse predicted dose, even with the OF Table extension. This is reflected by the fact that the output factor for 0.5 x 0.5 cm, calculated via Eclipse external beam, was more than 30% greater than that measured for both 6FFF and 6MV beams. Conclusions: Eclipse does a satisfactory job for primary jaw sizes down to 2 cm. For jaw settings smaller than 1.5 cm, the OF Table in Eclipse should be extended to improve the dose calculation accuracy.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Eclipse Output Factor Table: Should It Be Extended for Small Field Radiosurgery?
    Wu, G.
    Roberts, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E761 - E761
  • [2] Impact of Flattening Filter On Output Correction Factor of MicroDiamond Detector in Small-Field Stereotactic Radiosurgery Beams
    Arai, Y.
    Sato, Y.
    Takizawa, T.
    Fujii, K.
    Yasui, K.
    Sakai, K.
    Sato, M.
    Nakajima, Y.
    Fujita, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E948 - E948
  • [3] A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery
    Te-An Polly Huang
    Johnny E. Morales
    Ethan Butson
    Annie Johnson
    Martin Butson
    Robin Hill
    [J]. Physical and Engineering Sciences in Medicine, 2020, 43 : 593 - 599
  • [4] Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams
    Abdullah, R.
    Sapeei, M. S.
    Shukor, N. S. A.
    Yusof, M. F. M.
    Mohamed, M.
    Idris, N. R. N.
    Yusoff, A. L.
    Zakaria, A.
    Aziz, M. Z. A.
    [J]. INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [5] A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery
    Huang, Te-An Polly
    Morales, Johnny E.
    Butson, Ethan
    Johnson, Annie
    Butson, Martin
    Hill, Robin
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 593 - 599
  • [6] Small Field Dosimetry: Detector Dependency On Output Factor and Off-Axis-Ratio Measurements for a Novel Radiosurgery System
    Pinnaduwage, D.
    Srivastava, S.
    Yan, X.
    Jani, S.
    Jenkins, C.
    Weidlich, G.
    Bodduluri, M.
    Sorensen, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E218 - E218
  • [7] Comparison of small-field output factor measurements
    Oliver, C.
    Takau, V.
    Butler, D.
    Williams, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S765 - S765
  • [8] Intercomparison Study On Small Field Output Factor Measurements
    Talamonti, C.
    Casati, M.
    Compagnucci, A.
    Arilli, C.
    Greto, D.
    Marrazzo, L.
    Pallotta, S.
    Zani, M.
    Marinelli, M.
    Menichelli, D.
    Scotti, L.
    Verona, G.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3451 - 3451
  • [9] Use of an optical fiber dosimeter to measure small field output factors in stereotactic radiosurgery
    Miller, R. W.
    Ning, H.
    Justus, B.
    Huston, A.
    Li, G.
    Chang, J.
    Capala, J.
    Xie, H.
    Citrin, D.
    Camphausen, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S647 - S648
  • [10] Development of Simplified Measurement Technique for Small Field Output Factor
    Kim, M.
    Park, S.
    Ahn, S.
    Kim, J.
    Park, K.
    Lee, H.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E323 - E323