Super-Resolution Ultrasound Localization Microscopy Using High-Frequency Ultrasound to Measure Ocular Perfusion Velocity in the Rat Eye

被引:0
|
作者
Ul Banna, Hasan [1 ]
Mitchell, Benjamin [1 ]
Chen, Stephen [2 ]
Palko, Joel [1 ]
机构
[1] West Virginia Univ, Ophthalmol & Visual Sci, Morgantown, WV 26505 USA
[2] West Virginia Univ, Sch Med, Morgantown, WV 26505 USA
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 06期
关键词
glaucoma; intraocular pressure; ocular hemodynamics; ocular vasculature; super-resolution ultrasound; ultrasound localization microscopy;
D O I
10.3390/bioengineering10060689
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Imaging of the ocular vasculature can provide new insights into the pathophysiology of ocular diseases. This study proposes a novel high-frequency super-resolution ultrasound localization microscopy (SRULM) technique and evaluates its ability to measure in vivo perfusion changes in the rat eye at elevated intraocular pressure (IOP). A 38.4 MHz center frequency linear array transducer on a VisualSonics Vevo F2 imaging platform was used to collect high frame rate (1 kHz) radiofrequency data of the posterior rat eye following systemic microbubble contrast injection. Following clutter and spatiotemporal non-local means filtering, individual microbubbles were localized and tracked. The microbubble tracks were accumulated over 10,000 frames to generate vascular images quantifying perfusion velocity and direction. Experiments were performed using physiologic relevant controlled flow states for algorithm validation and subsequently performed in vivo on the rat eye at 10 mm Hg IOP increments from 10 to 60 mm Hg. The posterior vasculature of the rat eye, including the ophthalmic artery, long posterior ciliary arteries and their branches, central retinal artery and retinal arterioles and venules were successfully visualized, and velocities quantified at each IOP level. Significant reductions in arterial flow were measured as IOP was elevated. High-frequency SRULM can be used to visualize and quantify the perfusion velocity of the rat eye in both the retrobulbar and intraocular vasculature simultaneously. The ability to detect ocular perfusion changes throughout the depth of the eye may help elucidate the role ischemia has in the pathophysiology of ocular diseases such as glaucoma.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Antialiased super-resolution with parallel high-frequency synthesis
    Jiang, Xudong
    Sheng, Bin
    Lin, Weiyao
    Li, Ping
    Ma, Lizhuang
    Shen, Ruimin
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2017, 76 (01) : 543 - 560
  • [32] Antialiased super-resolution with parallel high-frequency synthesis
    Xudong Jiang
    Bin Sheng
    Weiyao Lin
    Ping Li
    Lizhuang Ma
    Ruimin Shen
    [J]. Multimedia Tools and Applications, 2017, 76 : 543 - 560
  • [33] High-Frequency Refinement for Sharper Video Super-Resolution
    Singh, Vikram
    Sharma, Akshay
    Devanathan, Sudharshann
    Mittal, Anurag
    [J]. 2020 IEEE WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV), 2020, : 3288 - 3297
  • [34] EXPERIMENTAL OCULAR LESIONS PRODUCED BY HIGH-FREQUENCY ULTRASOUND
    LIZZI, FL
    PACKER, A
    COLEMAN, DJ
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 59 : S59 - S60
  • [35] SUPER-RESOLUTION ULTRAWIDEBAND ULTRASOUND IMAGING USING FOCUSED FREQUENCY TIME REVERSAL MUSIC
    Foroozan, Foroohar
    Sadeghi, Parastoo
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 887 - 891
  • [36] Acoustic Wave Sparsely-Activated Localization Microscopy (AWSALM): In Vivo Fast Ultrasound Super-Resolution Imaging using Nanodroplets
    Zhang, Ge
    Harput, Sevan
    Toulemonde, Matthieu
    Broughton-Venner, Jacob
    Zhu, Jiaqi
    Riemer, Kai
    Christensen-Jeffries, Kirsten
    Brown, Jemma
    Eckersley, Robert J.
    Weinberg, Peter
    Dunsby, Chris
    Tang, Meng-Xing
    [J]. 2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1930 - 1933
  • [37] Fast Acoustic Wave Sparsely Activated Localization Microscopy: Ultrasound Super-Resolution Using Plane-Wave Activation of Nanodroplets
    Zhang, Ge
    Harput, Sevan
    Hu, Hanyu
    Christensen-Jeffries, Kirsten
    Zhu, Jiaqi
    Brown, Jemma
    Leow, Chee Hau
    Eckersley, Robert J.
    Dunsby, Christopher
    Tang, Meng-Xing
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (06) : 1039 - 1046
  • [38] Acoustic wave sparsely activated localization microscopy (AWSALM): Super-resolution ultrasound imaging using acoustic activation and deactivation of nanodroplets
    Zhang, Ge
    Harput, Sevan
    Lin, Shengtao
    Christensen-Jeffries, Kirsten
    Leow, Chee Hau
    Brown, Jemma
    Dunsby, Christopher
    Eckersley, Robert J.
    Tang, Meng-Xing
    [J]. APPLIED PHYSICS LETTERS, 2018, 113 (01)
  • [39] Velocity field estimation in transcranial small vessel using super-resolution ultrasound imaging velocimetry
    Liang, Meiling
    Liu, Jiacheng
    Guo, Chao
    Zong, Yujin
    Wan, Mingxi
    [J]. ULTRASONICS, 2023, 132
  • [40] Localization Microscopy: High power continuous wave lasers for super-resolution microscopy
    Klatt, Gregor
    Saroglou, Konstantinos
    Kobitski, Andrei
    Nienhaus, G. Ulrich
    [J]. PhotonicsViews, 2020, 17 (01): : 27 - 31