Biomechanical comparison of two different compression screws for the treatment of odontoid fractures in human dens axis specimen.

被引:0
|
作者
Mueller, Jan-Uwe [1 ]
Nowak, Stephan [1 ]
Matthes, Marc [1 ]
Pillich, Dirk Thomas [1 ]
Schroeder, Henry Werner Siegfried [1 ]
Schroeder, Siegfried [1 ]
Mueller, Jonas [1 ]
机构
[1] Univ Med, Dept Neurosurg, Greifswald, Germany
关键词
Odontoid fracture; Biomechanic; Osteoporosis; Neurosurgery; Spine trauma; COMPUTED TOMOGRAPHIC EVALUATION; OF-THE-NUT; ELDERLY-PATIENTS; THREAD DESIGN; CORTICAL BONE; HOLDING-POWER; II FRACTURES; FIXATION; PULLOUT; INSERTION;
D O I
10.1016/j.clinbiomech.2023.106162
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Lag screw osteosynthesis for odontoid fractures has a high rate of pseudoarthrosis, especially in elderly patients. Besides biomechanical properties of the different screw types, insufficient fragment compression or unnoticed screw stripping may be the main causing factors for this adverse event. The aim of the study was to compare two screws in clinical use with different design principles in terms of compression force and stability against screw stripping. Methods: Twelve human cadaveric C2 vertebral bodies were considered. Bone density was determined. The specimens were matched according to bone density and randomly assigned to two experimental groups. An odontoid fracture was induced, which were fixed either with a 3.5 mm standard compression screw or with a 5 mm sleeve nut screw. Both screws are certified for the treatment of odontoid fractures. The bone samples were fixed in a measuring device. The screwdriver was driven mechanically. The tests were analyzed for peak interfragmentary compression and screw-in torque with a frequency of 20 HzFindings: The maximum fragment compression was significantly higher with screw with sleeve nut at 346.13(SD +/- 72.35) N compared with classic compression screw at 162.68(SD +/- 114.13) N (p = 0.025). Screw stripping occurred significantly earlier in classic compression screw at 255.5(SD +/- 192.0)degrees rotation after reaching maximum compression than in screw with sleeve nut at 1005.2(SD +/- 341.1)degrees (p = 0.0039). Interpretation: Screw with sleeve nut achieves greater fragment compression and is more robust to screw stripping compared to classic compression screw. Whether the better biomechanical properties lead to a reduction of pseudoarthrosis has to be proven in clinical studies.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Comparison of two different ways to apply a circular plaster cast for distal radius fractures: biomechanical study
    Espejo-Reina, Alejandro
    Carrascal-Morillo, Maria T.
    Delgado-Martinez, Alberto D.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [32] Comparison of two different ways to apply a circular plaster cast for distal radius fractures: biomechanical study
    Alejandro Espejo-Reina
    María T. Carrascal-Morillo
    Alberto D. Delgado-Martínez
    Journal of Orthopaedic Surgery and Research, 16
  • [33] Treatment of distal radius fractures with palmar plates and locking screws. Comparisson of two different types of plate
    Declerq, Jonas
    Benis, Szabolcs
    Vanhove, Wim
    Hollevoet, Nadine
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (02): : 220 - 226
  • [34] Comparison of percutaneous compression plate to parallel screws in the treatment of nondisplaced femoral neck fractures in elderly patients: a prospective, randomized study
    Wang, Tao
    Yin, Haibo
    Zhao, Xijiang
    Ma, Chunhui
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7063 - 7071
  • [35] Comparison of percutaneous compression plate to parallel screws in the treatment of nondisplaced femoral neck fractures in elderly patients: a prospective, randomized study
    Tao Wang
    Haibo Yin
    Xijiang Zhao
    Chunhui Ma
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7063 - 7071
  • [36] Is Bridge Plating of Comminuted Humeral Shaft Fractures Advantageous When Using Compression Plates with Three versus Two Screws per Fragment? A Biomechanical Cadaveric Study
    Gomes, Guilherme Seva
    Zderic, Ivan
    Ahrend, Marc-Daniel
    Kojima, Kodi E.
    Varga, Peter
    Belangero, William Dias
    Richards, Geoff
    Lambert, Simon M.
    Gueorguiev, Boyko
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [37] Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Two Parallel Headless, Tapered, Variable-Pitched, Titanium Compression Screws and Two Parallel 5.5 mm Stainless-Steel Cortical Screws
    Wolker, Ryan R. E.
    Carmalt, James L.
    Wilson, David G.
    VETERINARY SURGERY, 2009, 38 (07) : 861 - 867
  • [38] Comparison of Atlantoaxial Rotation and Functional Outcomes of Two Nonfusion Techniques in the Treatment of Anderson-D'Alonzo Type II Odontoid Fractures
    Guo, Qunfeng
    Zhang, Mei
    Wang, Liang
    Lu, Xuhua
    Guo, Xiang
    Ni, Bin
    SPINE, 2016, 41 (12) : E751 - E758
  • [39] Comparison of Clinical Outcomes and Radiographic Measurements in 4 Different Treatment Modalities for Osteoporotic Compression Fractures Retrospective Analysis
    Ee, Gerard Wen Wei
    Lei, Jiang
    Guo, Chang Ming
    Yeo, William
    Tan, Seang Beng
    Tow, Phak Boon Benjamin
    Chen, Li Tat John
    Yue, Wai-Mun
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (06): : E328 - E335
  • [40] Biomechanical investigation of different surgical strategies for the treatment of rib fractures using a three-dimensional human respiratory model
    Shih, Kao-Shang
    Thanh An Truong
    Hsu, Ching-Chi
    Hou, Sheng-Mou
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (01): : 93 - 102