Biomechanical comparison of two different compression screws for the treatment of odontoid fractures in human dens axis specimen.

被引:0
|
作者
Mueller, Jan-Uwe [1 ]
Nowak, Stephan [1 ]
Matthes, Marc [1 ]
Pillich, Dirk Thomas [1 ]
Schroeder, Henry Werner Siegfried [1 ]
Schroeder, Siegfried [1 ]
Mueller, Jonas [1 ]
机构
[1] Univ Med, Dept Neurosurg, Greifswald, Germany
关键词
Odontoid fracture; Biomechanic; Osteoporosis; Neurosurgery; Spine trauma; COMPUTED TOMOGRAPHIC EVALUATION; OF-THE-NUT; ELDERLY-PATIENTS; THREAD DESIGN; CORTICAL BONE; HOLDING-POWER; II FRACTURES; FIXATION; PULLOUT; INSERTION;
D O I
10.1016/j.clinbiomech.2023.106162
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Lag screw osteosynthesis for odontoid fractures has a high rate of pseudoarthrosis, especially in elderly patients. Besides biomechanical properties of the different screw types, insufficient fragment compression or unnoticed screw stripping may be the main causing factors for this adverse event. The aim of the study was to compare two screws in clinical use with different design principles in terms of compression force and stability against screw stripping. Methods: Twelve human cadaveric C2 vertebral bodies were considered. Bone density was determined. The specimens were matched according to bone density and randomly assigned to two experimental groups. An odontoid fracture was induced, which were fixed either with a 3.5 mm standard compression screw or with a 5 mm sleeve nut screw. Both screws are certified for the treatment of odontoid fractures. The bone samples were fixed in a measuring device. The screwdriver was driven mechanically. The tests were analyzed for peak interfragmentary compression and screw-in torque with a frequency of 20 HzFindings: The maximum fragment compression was significantly higher with screw with sleeve nut at 346.13(SD +/- 72.35) N compared with classic compression screw at 162.68(SD +/- 114.13) N (p = 0.025). Screw stripping occurred significantly earlier in classic compression screw at 255.5(SD +/- 192.0)degrees rotation after reaching maximum compression than in screw with sleeve nut at 1005.2(SD +/- 341.1)degrees (p = 0.0039). Interpretation: Screw with sleeve nut achieves greater fragment compression and is more robust to screw stripping compared to classic compression screw. Whether the better biomechanical properties lead to a reduction of pseudoarthrosis has to be proven in clinical studies.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Proximal screws placement in intertrochanteric fractures treated with external fixation: comparison of two different techniques
    Vekris, Marios D.
    Lykissas, Marios G.
    Manoudis, Gregory
    Mavrodontidis, Alexandros N.
    Papageorgiou, Christos D.
    Korompilias, Anastasios V.
    Kostas-Agnantis, Ioannis P.
    Beris, Alexandros E.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6
  • [22] Bone substitute first or screws first? A biomechanical comparison of two operative techniques for tibial-head depression fractures
    Hoelscher-Doht, Stefanie
    Jordan, Martin Cornelius
    Bonhoff, Christina
    Frey, Soenke
    Blunk, Torsten
    Meffert, Rainer H.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (06) : 978 - 983
  • [23] Comparison of dynamic compression system versus multiple cancellous screws in the treatment of femoral neck fractures in young adults
    Aljasim, Omar
    Yener, Can
    Ozkayin, Nadir
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [24] Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model
    Palierne, Sophie
    Blondel, Margaux
    Swider, Pascal
    Autefage, Andre
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 35 (03) : 166 - 174
  • [25] Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures
    Schwartz, Alexandra
    Oka, Richard
    Odell, Tim
    Mahar, Andrew
    CLINICAL BIOMECHANICS, 2006, 21 (09) : 950 - 955
  • [26] Biomechanical comparison of two different wire stretching methods in the treatment of tibial plateau fractures with the Ilizarov technique and the related clinical results
    Cavusoglu, Turgay
    Ozsoy, M. Hakan
    Dincel, V. Ercan
    Senkoylue, Alpaslan
    Sakaogullari, Abdurrahman
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2009, 20 (01): : 2 - 10
  • [27] A Biomechanical Comparison of Locked Unicortical with Non-Locking Bicortical Screws for Metacarpal Shaft Fractures in a Randomized Human Cadaveric Model
    Minogue, Febe
    Reilly, Keryn
    Walker, Cameron
    Malak, Sharif
    Mayo, Andrew
    Heiss-Dunlop, Wolfgang
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2021, 26 (01): : 10 - 16
  • [28] Biomechanical comparison of different pin configurations during percutaneous pinning for the treatment of proximal humeral fractures
    Jiang, Chunyan
    Zhu, Yiming
    Wang, Manyi
    Rong, Guowei
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (02) : 235 - 239
  • [29] Biomechanical study of two different fixation methods for the treatment of Neer III proximal humerus fractures
    Cheng, Bangjun
    Jiang, Xiping
    Zhang, Xiaofeng
    Guo, Shixin
    Chen, Qi
    Du, Shengchao
    Luo, Yi
    He, Yaohua
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [30] Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: Biomechanical comparison studies on cadaveric bones
    Konstantinidis, L.
    Hauschild, O.
    Beckmann, N. A.
    Hirschmueller, A.
    Suedkamp, N. P.
    Helwig, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (12): : 1256 - 1261