Seismic performance assessment of deteriorated reinforced concrete columns using a new plastic-hinge element

被引:0
|
作者
Kim, Tae-Hoon [1 ]
Jung, Hosung [2 ]
机构
[1] Korea Railroad Res Inst, Adv Railroad Civil Engn Div, 176 Cheoldobangmulgwan Ro, Uiwang Si 16105, Gyeonggi Do, South Korea
[2] Korea Railroad Res Inst, Smart Elect Signaling Div, 176 Cheoldobangmulgwan Ro, Uiwang Si 16105, Gyeonggi Do, South Korea
来源
COMPUTERS AND CONCRETE | 2023年 / 32卷 / 02期
关键词
column; deteriorated; plastic-hinge element; reinforced concrete; seismic performance; BRIDGE PIERS; BEHAVIOR; CORROSION; DUCTILITY; STRENGTH; CAPACITY; MODEL;
D O I
10.12989/cac.2023.32.2.139
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The purpose of this paper is to numerically assess the seismic performance of deteriorated reinforced concrete columns using a new plastic-hinge element. Developing a three dimensional (3D) nonlinear model can be difficult and computationally complex, and there can be problems applying it in the field. Thus, to solve these problems, a plastic-hinge element that could considers the shear deformation of deteriorated reinforced concrete columns was proposed. The developed element was based on the Timoshenko beam model and used two nodes with six degrees of freedom and a zero-length element. Moreover, the developed model could consider the combined effects of corrosion, as demonstrated by the reduced reinforcement area and the loss of bond. Consequently, the numerical procedures developed for evaluating the seismic performance of deteriorated columns were validated by comparing the verification results.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [41] Displacement and plastic hinge length of FRP-confined circular reinforced concrete columns
    Youssf, Osama
    ElGawady, Mohamed A.
    Mills, Julie E.
    ENGINEERING STRUCTURES, 2015, 101 : 465 - 476
  • [42] Probabilistic Model for Equivalent Plastic Hinge Length of Reinforced Concrete Columns Considering Uncertainties
    Yu B.
    Li S.
    Yu Z.
    Zhang Q.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2024, 32 (03): : 839 - 849
  • [43] Structural performance assessment of deteriorated reinforced concrete bridge piers
    Kim, T. H.
    COMPUTERS AND CONCRETE, 2014, 14 (04): : 387 - 403
  • [44] Hysteretic model parameters for seismic performance assessment of cyclically degraded reinforced concrete columns
    Park, Yewon
    Chang Seok, Lee
    Jeon, Jong -Su
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 179
  • [45] Seismic performance assessment of reinforced concrete bridge columns under variable axial load
    Kim, T. -H.
    Kim, Y. -J.
    Shin, H. M.
    MAGAZINE OF CONCRETE RESEARCH, 2007, 59 (02) : 87 - 96
  • [46] Seismic performance analysis of RC shear wall structure with fiber-reinforced concrete in plastic hinge region
    Han, Jun
    Zhai, Yonglin
    Zhang, Hui
    Li, Yingmin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 47 - 54
  • [47] Research on the seismic performance of precast concrete columns with replaceable bionic hinge connections
    Yuan, Yu-Jie
    Qi, Shuai
    Shi, Yan-Li
    Wang, Wen-Da
    STRUCTURES, 2024, 70
  • [48] Seismic assessment of reinforced concrete columns with short lap splices
    Opabola, Eyitayo A.
    Elwood, Kenneth J.
    EARTHQUAKE SPECTRA, 2021, 37 (03) : 1726 - 1757
  • [49] Performance assessment of reinforced concrete bridge columns using a damage index
    Kim, Tae-Hoon
    Kim, Young-Jin
    Kang, Hyeong-Taek
    Shin, Hyun Mock
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2007, 34 (07) : 843 - 855
  • [50] Application of engineered cementitious composites in the plastic hinge of reinforced concrete beams for seismic enhancing
    Zhang, Yangxi
    Yao, Xinyuan
    Li, Tong
    Deng, Mingke
    STRUCTURAL CONCRETE, 2022, 23 (05) : 2732 - 2747