Displacement and plastic hinge length of FRP-confined circular reinforced concrete columns

被引:69
|
作者
Youssf, Osama [1 ]
ElGawady, Mohamed A. [2 ]
Mills, Julie E. [1 ]
机构
[1] Univ S Australia, Adelaide, SA 5001, Australia
[2] Missouri Univ Sci & Technol, Rolla, MO 65409 USA
关键词
FRP-confined concrete; RC columns; Plastic hinge length; Ultimate drift ratio; Finite element analysis; LS-DYNA; SEISMIC BEHAVIOR; RC COLUMNS; DESIGN; PERFORMANCE; BEAMS;
D O I
10.1016/j.engstruct.2015.07.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Confinement of both existing and newly constructed reinforced concrete (RC) columns by fibre reinforced polymer (FRP) has been commonly used in recent decades. This is because of its ability to enhance the shear resistance and the ductility of the RC columns, which are the main parameters that govern the behaviour of RC columns under lateral loading. This paper presents a finite element (FE) model that was developed using the LS-DYNA program aimed at modelling the plastic hinge length (43) for FRP-confined RC columns. A FE parametric study was conducted to investigate the effect of FRP-confinement on l(p). Empirical models were proposed to predict l(p) and the ultimate drift ratio (delta(u)) for FRP-confined RC columns and the results were compared with similar previous models. The proposed FE model was able to predict the plastic hinge region and l(p) value which can provide a simple way for designers to investigate the behaviour of FRP-confined columns during the design process. The proposed Si, model reduced the average of errors (A) and standard deviation (SD) by 15.1%, 3.9%, respectively, compared to the best predictions by previous models. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:465 / 476
页数:12
相关论文
共 50 条
  • [1] Plastic Hinge Length of FRP-Confined Square RC Columns
    Jiang, Cheng
    Wu, Yu-Fei
    Wu, Gang
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (04)
  • [2] Plastic hinge analysis of FRP confined circular concrete columns
    Gu, Dong-Sheng
    Wu, Yu-Fei
    Wu, Gang
    Wu, Zhi-shen
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2012, 27 (01) : 223 - 233
  • [3] Behaviour of FRP-confined circular reinforced concrete columns in fire
    Han, Lin-Hai
    Zheng, Yong-Qian
    Teng, Jin-Guang
    [J]. Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 184 - 190
  • [4] Analytical model for FRP-confined circular reinforced concrete columns
    Eid, R.
    Paultre, P.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (05) : 541 - 552
  • [5] Plastic hinge length of circular reinforced concrete columns
    Ou, Yu-Chen
    Kurniawan, Raditya Andy
    Kurniawan, Dimas Pramudya
    Nguyen Dang Nguyen
    [J]. COMPUTERS AND CONCRETE, 2012, 10 (06): : 663 - 681
  • [6] Modelling plastic hinge of FRP-confined RC columns
    Yuan, Fang
    Wu, Yu-Fei
    Li, Chun-Qing
    [J]. ENGINEERING STRUCTURES, 2017, 131 : 651 - 668
  • [7] Effect of Interfacial Bond on Plastic Hinge Length of FRP-Confined RC Columns
    Jiang, Cheng
    Yuan, Fang
    Wu, Yu-Fei
    Zhao, Xue-Mei
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2019, 23 (02)
  • [8] Axial-flexural interaction in circular FRP-confined reinforced concrete columns
    Bisby, Luke
    Ranger, Michael
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (09) : 1672 - 1681
  • [9] Damping determination of FRP-confined reinforced concrete columns
    Li, Xiaoran
    Wang, Yuanfeng
    Su, Li
    [J]. COMPUTERS AND CONCRETE, 2014, 14 (02): : 163 - 174
  • [10] Compressive behavior of FRP-confined reinforced concrete columns
    Eid, Rami
    Paultre, Patrick
    [J]. ENGINEERING STRUCTURES, 2017, 132 : 518 - 530