Energy-exergy analysis for performance improvement of Brayton-Rankine combined cycle system by utilizing a solar absorption refrigeration cycle (case study: Kahnuj Combined Cycle Power Plant)

被引:1
|
作者
Esfandiari, Moslem [1 ]
Pourfayaz, Fathollah [1 ]
Kasaeian, Alibakhsh [1 ]
Gholami, Ali [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
关键词
combined cycle power plant; energy; exergy; solar absorption refrigeration cycle; GAS-TURBINE ENGINES; INLET AIR;
D O I
10.1002/ese3.1629
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Gas-steam combined cycle power plants are the most efficient electricity-generation units based on fossil fuels. However, these power plants are prone to efficiency decrease in hot climates as high ambient temperatures adversely influence the gas turbine's output. The present study investigated the effect of incorporating a solar absorption refrigeration (SAR) system into an actual combined cycle power plant for the first time. First, the energy and exergy analyses were performed using THERMOFLOW software. Then, the influence of the ambient temperature (10 degrees C-52.5 degrees C) on the power plant's performance and its components was investigated. The SAR system was then used to cool the compressor's input air and improve the power generation capacity by employing TRNSYS software. The results showed that the power plant reached its maximum efficiency at an ambient temperature of 26.6 degrees C. However, its overall efficiency and net power generation were dropped with a further increase in the ambient temperature. Employing the SAR system for each gas turbine in the power plant on a sunny day until 2 p.m. would decrease the compressor's input air temperature. For example, for the refrigeration capacities of 450, 700, and 1000 tons for each gas turbine, the temperature was reduced by nearly 3 degrees C, 5 degrees C, and 7 degrees C, respectively. Under the same condition, power generation capacity improved by 12.5, 24, and 32.5 MW, and the overall efficiency rose by 0.6%, 1.4%, and 2%. Such an increase in power and efficiency occurred during peak demand, which was significant. Solar collectors are utilized to provide the heat source for the absorption refrigeration cycle. The compressor's inlet air temperature is reduced by the absorption refrigeration cycle, increasing the Brayton-Rankine cycle's efficiency.image
引用
收藏
页码:201 / 214
页数:14
相关论文
共 50 条
  • [41] Energy-exergy performance assessment with optimization guidance for the components of the 396-MW combined-cycle power plant
    Babaei Jamnani, Mohammadreza
    Kardgar, Amin
    ENERGY SCIENCE & ENGINEERING, 2020, 8 (10) : 3561 - 3574
  • [42] Performance Analysis and Comprehensive Evaluation of Solar Organic Rankine Cycle Combined with Transcritical CO2 Refrigeration Cycle
    Zhang, Na
    Xu, Po
    Wang, Yiming
    Tong, Wencai
    Yang, Zhao
    ENERGIES, 2023, 16 (14)
  • [43] Working fluid selection, exergy, energy and exergoeconomic assessment of a novel combined Brayton cycle and regenerative-recuperative organic Rankine cycle for concentrated solar power application
    Khan, Yunis
    Singh, Pawan Kumar
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2024, 46 (12)
  • [44] Energy and exergy analysis of brayton-brayton hybrid cycle for power plant applications
    Sanjay, 1600, International Association of Engineers (22):
  • [45] Energy and Exergy Analyses of an Existing Solar-Assisted Combined Cycle Power Plant
    Temraz, Ayman
    Rashad, Ahmed
    Elweteedy, Ahmed
    Alobaid, Falah
    Epple, Bernd
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [46] Exergy optimisation of irreversible closed Brayton cycle combined cooling, heating and power plant
    Chen, L. G.
    Feng, H. J.
    Sun, F. R.
    JOURNAL OF THE ENERGY INSTITUTE, 2013, 86 (02) : 97 - 106
  • [47] Analysis of a Combined Power and Ejector-Refrigeration Cycle Based on Solar Energy
    Sheykhlou, H.
    Jafarmadar, S.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2016, 40 (01) : 57 - 67
  • [48] Sensitivity analysis of ammonia absorption power/refrigeration combined cycle
    Luo, Chen-Ding
    Zhang, Na
    Cai, Rui-Xian
    Liu, Meng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (17): : 1 - 7
  • [49] Thermodynamic performance assessment of solar-based combined power and absorption refrigeration cycle
    Parvez, Mohd
    Khalid, Faizan
    Khan, Osama
    INTERNATIONAL JOURNAL OF EXERGY, 2020, 31 (03) : 232 - 248
  • [50] Working fluid selection for regenerative supercritical Brayton cycle combined with bottoming ORC driven by molten salt solar power tower using energy-exergy analysis
    Habibi, Hamed
    Zoghi, Mohammad
    Chitsaz, Ata
    Javaherdeh, Koroush
    Ayazpour, Mojtaba
    Bellos, Evangelos
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 39