Energy-exergy analysis for performance improvement of Brayton-Rankine combined cycle system by utilizing a solar absorption refrigeration cycle (case study: Kahnuj Combined Cycle Power Plant)

被引:1
|
作者
Esfandiari, Moslem [1 ]
Pourfayaz, Fathollah [1 ]
Kasaeian, Alibakhsh [1 ]
Gholami, Ali [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
关键词
combined cycle power plant; energy; exergy; solar absorption refrigeration cycle; GAS-TURBINE ENGINES; INLET AIR;
D O I
10.1002/ese3.1629
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Gas-steam combined cycle power plants are the most efficient electricity-generation units based on fossil fuels. However, these power plants are prone to efficiency decrease in hot climates as high ambient temperatures adversely influence the gas turbine's output. The present study investigated the effect of incorporating a solar absorption refrigeration (SAR) system into an actual combined cycle power plant for the first time. First, the energy and exergy analyses were performed using THERMOFLOW software. Then, the influence of the ambient temperature (10 degrees C-52.5 degrees C) on the power plant's performance and its components was investigated. The SAR system was then used to cool the compressor's input air and improve the power generation capacity by employing TRNSYS software. The results showed that the power plant reached its maximum efficiency at an ambient temperature of 26.6 degrees C. However, its overall efficiency and net power generation were dropped with a further increase in the ambient temperature. Employing the SAR system for each gas turbine in the power plant on a sunny day until 2 p.m. would decrease the compressor's input air temperature. For example, for the refrigeration capacities of 450, 700, and 1000 tons for each gas turbine, the temperature was reduced by nearly 3 degrees C, 5 degrees C, and 7 degrees C, respectively. Under the same condition, power generation capacity improved by 12.5, 24, and 32.5 MW, and the overall efficiency rose by 0.6%, 1.4%, and 2%. Such an increase in power and efficiency occurred during peak demand, which was significant. Solar collectors are utilized to provide the heat source for the absorption refrigeration cycle. The compressor's inlet air temperature is reduced by the absorption refrigeration cycle, increasing the Brayton-Rankine cycle's efficiency.image
引用
收藏
页码:201 / 214
页数:14
相关论文
共 50 条
  • [21] Energy and Exergy Analysis of Solar Organic Rankine Cycle Coupled with Vapor Compression Refrigeration Cycle
    Kim, Man-Hoe
    ENERGIES, 2022, 15 (15)
  • [22] Exergy-economic analysis of a hybrid combined supercritical Brayton cycle-organic Rankine cycle using biogas and solar PTC system as energy sources
    Alghamdi, Ahmed
    Ponnore, Joffin Jose
    Hassan, Ahmed M.
    Alqahtani, Sultan
    Alshehery, Sultan
    Anqi, Ali E.
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 50
  • [23] Performance Analysis and Optimization of a Novel Combined Cooling, Heating, and Power System-Integrated Rankine Cycle and Brayton Cycle Utilizing the Liquified Natural Gas Cold Energy
    Sun, Wenyi
    Shang, Liyan
    Pan, Zhen
    Liu, Peisheng
    Cui, Xinshuo
    Zhu, Jian
    Sun, Xiangguang
    ENERGY TECHNOLOGY, 2022, 10 (11)
  • [24] Thermo-economic analysis of a solar combined cycle with Brayton, Kalina, and organic Rankine cycle
    Pandey, Mukundjee
    Padhi, Biranchi Narayana
    Mishra, Ipsita
    INTERNATIONAL JOURNAL OF EXERGY, 2023, 40 (04) : 392 - 413
  • [25] Energy and Exergy Analysis of Combined Organic Rankine Cycle-Single and Dual Evaporator Vapor Compression Refrigeration Cycle
    Pektezel, Oguzhan
    Acar, Halil Ibrahim
    APPLIED SCIENCES-BASEL, 2019, 9 (23):
  • [26] Performance analysis of a combined power and refrigeration cycle
    Bian, Yongning
    Pan, Junxiu
    Liu, Yang
    Zhang, Fengge
    Yang, Yunjie
    Arima, Hirofumi
    ENERGY CONVERSION AND MANAGEMENT, 2019, 185 : 259 - 270
  • [27] Exergy analysis of a natural gas combined cycle power plant: a case study
    Pinto, Gabriel Marques
    Rodriguez Coronado, Christian Jeremi
    Zucareli de Souza, TOlio Augusto
    D'Oliveira Santos, Eudes Muller
    INTERNATIONAL JOURNAL OF EXERGY, 2022, 37 (02) : 159 - 180
  • [28] Thermoeconomic analysis of a novel combined cooling, heating and power system based on solar organic Rankine cycle and cascade refrigeration cycle
    Aghaziarati, Zeinab
    Aghdam, Abolfazl Hajizadeh
    RENEWABLE ENERGY, 2021, 164 : 1267 - 1283
  • [29] Energy, exergy and exergoeconomic (3E) analyses of an organic Rankine cycle integrated combined cycle power plant
    Gogoi, T. K.
    Lahon, Dibyani
    Nondy, J.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41
  • [30] Analysis of a Combined Power and Ejector–Refrigeration Cycle Based on Solar Energy
    H. Sheykhlou
    S. Jafarmadar
    Iranian Journal of Science and Technology, Transactions of Mechanical Engineering, 2016, 40 : 57 - 67