Baseplate inferior offset affects shoulder range of motion in reverse shoulder arthroplasty in Asian population

被引:0
|
作者
Yamada, Erina [1 ]
Kozono, Naoya [1 ]
Nabeshima, Akira [1 ]
Tashiro, Eiji [1 ]
Nakashima, Yasuharu [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, 3-1-1 Maidashi,Higashi Ku, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
Reverse total shoulder arthroplasty; Simulation; Asian; Impingement; Offset; CONCENTRIC GLENOSPHERE; GLENOID LATERALIZATION; ECCENTRIC GLENOSPHERE; SCAPULAR NECK; COMPONENT; TILT; IMPINGEMENT; POSITION; OUTCOMES; DESIGN;
D O I
10.1186/s13018-023-04506-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundImpingement is a common complication of reverse shoulder arthroplasty. Placement of the baseplate with a wide impingement-free angle is ideal; however, there are few studies on Asian populations, which have smaller height and physique, and there is a lack of guidance on achieving optimal outcomes. The purpose of the present study was to explore the impingement-free range of motion reverse shoulder arthroplasty and analyze the suitable baseplate position or tilt for the Asian population using simulation software.MethodsWe uploaded computed tomography scan data from 20 Asian patients to three-dimensional (3D) simulation software. The implantation of the reverse shoulder arthroplasty component was performed on the 3D humerus and scapula using software, and range of motion was assessed until impingement occurred.ResultsThe range of motion in flexion significantly improved when the baseplate was lowered up to 3 mm inferiorly. Range of motion in abduction and internal and external rotation significantly improved as the baseplate was lowered up to 4 mm. There was no significant difference in range of motion in any motion after changing the inferior tilt, except in internal and external rotation.ConclusionsThe range of motion in abduction, flexion, and internal and external rotations significantly improved with increased inferior offset. These results may prove valuable in determining the optimal baseplate position for RSA, particularly in Asian populations.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Influence of Glenosphere and baseplate parameters on Glenoid bone strains in reverse shoulder Arthroplasty
    Leo Pauzenberger
    Cory Dwyer
    Elifho Obopilwe
    Michael D. Nowak
    Mark Cote
    Anthony A. Romeo
    Augustus D. Mazzocca
    Felix Dyrna
    BMC Musculoskeletal Disorders, 20
  • [42] Offset in Reverse Shoulder Arthroplasty: Where, When, and How Much
    Wright, Melissa A.
    Murthi, Anand M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (03) : 89 - 99
  • [43] METALLIC LATERALIZED-OFFSET GLENOID REVERSE SHOULDER ARTHROPLASTY
    Maggini, Emanuele
    Warnhoff, Mara
    Freislederer, Florian
    Scheibel, Markus
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2024, 14 (03):
  • [44] Humeral offset as a predictor of outcomes after reverse shoulder arthroplasty
    Carrazana-Suarez, Luis F.
    Panico, Leighann C.
    Smolinski, Michael P.
    Blake, Ryan J.
    McCroskey, Miranda A.
    Sykes, Joshua B.
    Lin, Albert
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (06) : S158 - S165
  • [45] Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model
    Gutierrez, Sergio
    Levy, Jonathan C.
    Frankle, Mark A.
    Cuff, Derek
    Keller, Tony S.
    Pupello, Derek R.
    Lee, William E., III
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (04) : 608 - 615
  • [46] Reverse Shoulder Arthroplasty
    Nally, D.
    Molloy, A.
    Mullet, H.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2012, 181 : S187 - S188
  • [47] Reverse Shoulder Arthroplasty
    Jarrett, Claudius D.
    Brown, Brandon T.
    Schmidt, Christopher C.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2013, 44 (03) : 389 - +
  • [48] Reverse shoulder arthroplasty
    Smithers C.J.
    Young A.A.
    Walch G.
    Current Reviews in Musculoskeletal Medicine, 2011, 4 (4) : 183 - 190
  • [49] Assessment of Isokinetics and Range of Motion of the Shoulder in Patients after Reverse Shoulder Arthroplasty in the Late Follow-Up Period
    Ogrodzka-Ciechanowicz, Katarzyna
    Kurzeja, Piotr
    Sorysz, Tomasz
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [50] Can a reverse shoulder arthroplasty be used to revise a failed primary reverse shoulder arthroplasty? REVISION REVERSE SHOULDER ARTHROPLASTY FOR FAILED REVERSE PROSTHESIS
    Wagner, E. R.
    Hevesi, M.
    Houdek, M. T.
    Cofield, R. H.
    Sperling, J. W.
    Sanchez-Sotelo, J.
    BONE & JOINT JOURNAL, 2018, 100B (11): : 1493 - 1498