Baseplate inferior offset affects shoulder range of motion in reverse shoulder arthroplasty in Asian population

被引:0
|
作者
Yamada, Erina [1 ]
Kozono, Naoya [1 ]
Nabeshima, Akira [1 ]
Tashiro, Eiji [1 ]
Nakashima, Yasuharu [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, 3-1-1 Maidashi,Higashi Ku, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
Reverse total shoulder arthroplasty; Simulation; Asian; Impingement; Offset; CONCENTRIC GLENOSPHERE; GLENOID LATERALIZATION; ECCENTRIC GLENOSPHERE; SCAPULAR NECK; COMPONENT; TILT; IMPINGEMENT; POSITION; OUTCOMES; DESIGN;
D O I
10.1186/s13018-023-04506-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundImpingement is a common complication of reverse shoulder arthroplasty. Placement of the baseplate with a wide impingement-free angle is ideal; however, there are few studies on Asian populations, which have smaller height and physique, and there is a lack of guidance on achieving optimal outcomes. The purpose of the present study was to explore the impingement-free range of motion reverse shoulder arthroplasty and analyze the suitable baseplate position or tilt for the Asian population using simulation software.MethodsWe uploaded computed tomography scan data from 20 Asian patients to three-dimensional (3D) simulation software. The implantation of the reverse shoulder arthroplasty component was performed on the 3D humerus and scapula using software, and range of motion was assessed until impingement occurred.ResultsThe range of motion in flexion significantly improved when the baseplate was lowered up to 3 mm inferiorly. Range of motion in abduction and internal and external rotation significantly improved as the baseplate was lowered up to 4 mm. There was no significant difference in range of motion in any motion after changing the inferior tilt, except in internal and external rotation.ConclusionsThe range of motion in abduction, flexion, and internal and external rotations significantly improved with increased inferior offset. These results may prove valuable in determining the optimal baseplate position for RSA, particularly in Asian populations.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Outcomes after revision surgery for glenoid baseplate failure in reverse shoulder arthroplasty
    Chen, Raymond E.
    Vaughan, Alayna K.
    Singh, Jaspal
    Lazarus, Mark D.
    Williams, Gerald R.
    Namdari, Surena
    SHOULDER & ELBOW, 2025, 17 (01) : 63 - 68
  • [32] Factors contributing to glenoid baseplate micromotion in reverse shoulder arthroplasty: a biomechanical study
    Lung, Tiffany S.
    Cruickshank, David
    Grant, Heather J.
    Rainbow, Michael J.
    Bryant, Timothy J.
    Bicknell, Ryan T.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) : 648 - 653
  • [33] Influence of Glenosphere and baseplate parameters on Glenoid bone strains in reverse shoulder Arthroplasty
    Pauzenberger, Leo
    Dwyer, Cory
    Obopilwe, Elifho
    Nowak, Michael D.
    Cote, Mark
    Romeo, Anthony A.
    Mazzocca, Augustus D.
    Dyrna, Felix
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [34] A nondestructive method to verify the glenosphere-baseplate assembly in reverse shoulder arthroplasty
    Leuridan, Steven
    Goossens, Quentin
    Pastrav, Leonard
    Van Tongel, Alexander
    De Wilde, Lieven
    Debeer, Philippe
    Denis, Kathleen
    Desmet, Wim
    Sloten, Jos Vander
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : E156 - E165
  • [35] Comparing daily shoulder motion and frequency after anatomic and reverse shoulder arthroplasty
    Langohr, G. Daniel G.
    Haverstock, John P.
    Johnson, James A.
    Athwal, George S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) : 325 - 332
  • [36] Reverse total shoulder arthroplasty for failed shoulder arthroplasty
    Patel, Deepan N.
    Young, Brett
    Onyekwelu, Ikemefuna
    Zuckerman, Joseph D.
    Kwon, Young W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (11) : 1478 - 1483
  • [37] Superior Baseplate Inclination Is Associated With Instability After Reverse Total Shoulder Arthroplasty
    McFarland, Edward G.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (08) : 1630 - 1632
  • [38] Baseplate retroversion does not affect postoperative outcomes after reverse shoulder arthroplasty
    Elmallah, Randa
    Swanson, Daniel
    Le, Kiet
    Kirsch, Jacob
    Jawa, Andrew
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (10) : 2082 - 2088
  • [39] Kinematic analysis of dynamic shoulder motion in patients with reverse total shoulder arthroplasty
    Kwon, Young W.
    Pinto, Vivek J.
    Yoon, Jangwhon
    Frankle, Mark A.
    Dunning, Page E.
    Sheikhzadeh, Ali
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (09) : 1184 - 1190
  • [40] How to avoid baseplate failure: the effect of compression and reverse shoulder arthroplasty baseplate design on implant stability
    Diaz, Miguel A.
    Hutchinson, Adam J.
    Ricchetti, Eric T.
    Hsu, Jason E.
    Garrigues, Grant E.
    Gutierrez, Sergio
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (02) : 389 - 398