摘要
BackgroundImpingement is a common complication of reverse shoulder arthroplasty. Placement of the baseplate with a wide impingement-free angle is ideal; however, there are few studies on Asian populations, which have smaller height and physique, and there is a lack of guidance on achieving optimal outcomes. The purpose of the present study was to explore the impingement-free range of motion reverse shoulder arthroplasty and analyze the suitable baseplate position or tilt for the Asian population using simulation software.MethodsWe uploaded computed tomography scan data from 20 Asian patients to three-dimensional (3D) simulation software. The implantation of the reverse shoulder arthroplasty component was performed on the 3D humerus and scapula using software, and range of motion was assessed until impingement occurred.ResultsThe range of motion in flexion significantly improved when the baseplate was lowered up to 3 mm inferiorly. Range of motion in abduction and internal and external rotation significantly improved as the baseplate was lowered up to 4 mm. There was no significant difference in range of motion in any motion after changing the inferior tilt, except in internal and external rotation.ConclusionsThe range of motion in abduction, flexion, and internal and external rotations significantly improved with increased inferior offset. These results may prove valuable in determining the optimal baseplate position for RSA, particularly in Asian populations.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Baseplate inferior offset affects shoulder range of motion in reverse shoulder arthroplasty in Asian population
    Erina Yamada
    Naoya Kozono
    Akira Nabeshima
    Eiji Tashiro
    Yasuharu Nakashima
    Journal of Orthopaedic Surgery and Research, 19
  • [2] Risk of penetration of the baseplate peg in reverse total shoulder arthroplasty for an Asian population
    Tashiro, Eiji
    Takeuchi, Naohide
    Kozono, Naoya
    Nabeshima, Akira
    Teshima, Ei
    Nakashima, Yasuharu
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (05) : 1063 - 1071
  • [3] Risk of penetration of the baseplate peg in reverse total shoulder arthroplasty for an Asian population
    Eiji Tashiro
    Naohide Takeuchi
    Naoya Kozono
    Akira Nabeshima
    Ei Teshima
    Yasuharu Nakashima
    International Orthopaedics, 2022, 46 : 1063 - 1071
  • [4] Center of rotation affects abduction range of motion of reverse shoulder arthroplasty
    Gutierrez, Sergio
    Levy, Jonathan C.
    Lee, William E., III
    Keller, Tony S.
    Maitland, Murray E.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (458) : 78 - 82
  • [5] Effect of posterior offset humeral components on range of motion in reverse shoulder arthroplasty
    Dedy, Nicolas J.
    Stangenberg, Martin
    Liem, Dennis
    Hurschler, Christof
    Simmen, Beat
    Riner, Marc
    Marquardt, Bjoern
    Steinbeck, Joern
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (04) : 549 - 554
  • [6] Effect of posterior offset humeral components on range of motion in reverse shoulder arthroplasty
    Nicolas J. Dedy
    Martin Stangenberg
    Dennis Liem
    Christof Hurschler
    Beat Simmen
    Marc Riner
    Bjoern Marquardt
    Joern Steinbeck
    International Orthopaedics, 2011, 35 : 549 - 554
  • [7] Optimizing range of motion in reverse shoulder arthroplasty
    Mouchantaf, M.
    Parisi, M.
    Secci, G.
    Biegun, M.
    Chelli, M.
    Schippers, P.
    Boileau, P.
    BONE & JOINT OPEN, 2024, 5 (10): : 851 - 857
  • [8] Revision reverse shoulder arthroplasty for glenoid baseplate failure after primary reverse shoulder arthroplasty
    Holcomb, Jason O.
    Cuff, Derek
    Petersen, Steve A.
    Pupello, Derek R.
    Rankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (05) : 717 - 723
  • [9] Baseplate Options for Reverse Total Shoulder Arthroplasty
    Wassim Mourad
    J. Michael Wiater
    Brett P. Wiater
    Alexander Martusiewicz
    Current Reviews in Musculoskeletal Medicine, 2020, 13 : 769 - 775
  • [10] Baseplate Options for Reverse Total Shoulder Arthroplasty
    Mourad, Wassim
    Wiater, J. Michael
    Wiater, Brett P.
    Martusiewicz, Alexander
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2020, 13 (06) : 769 - 775