Optimal sensor placement methodology of triaxial accelerometers using combined metaheuristic algorithms for structural health monitoring applications

被引:8
|
作者
Mghazli, Mohamed Oualid [1 ,2 ,3 ]
Zoubir, Zineb [1 ,4 ]
Nait-Taour, Abdellah [1 ]
Cherif, Seifeddine [5 ]
Lamdouar, Nouzha [3 ]
El Mankibi, Mohamed [2 ]
机构
[1] Green Energy Pk, UM6P, IRESEN, km2 R206, Benguerir, Morocco
[2] Univ Lyon, ENTPE, LTDS, UMR CNRS 5513, Vaulx en Velin, France
[3] Mohammed V Univ Rabat, Mohammadia Sch Engineers, Civil Engn Lab, Rabat, Morocco
[4] Mohammed VI Polytech Univ Morocco, Sch Ind Management, EMINES, Ben Guerir, Morocco
[5] Cadi Ayyad Univ, Fac Sci & Technol, Geoenvironm & Civil Engn Lab L3G, Georessources, Marrakech 40000, Morocco
关键词
Optimal sensor placement; Metaheuristic algorithms; Combinatorial optimization; Structural health monitoring; High rise buildings; OPTIMIZATION; CONFIGURATION;
D O I
10.1016/j.istruc.2023.03.093
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Structural health monitoring applications present a valuable opportunity for cities to improve their in-frastructures environmental life cycle, reduce operational maintenance cost and enhance their resiliency through early damage detection capabilities. The dilemma with structural health monitoring resides in balancing between the number of sensors to be installed and the amount of data that needs to be transferred, stored, and managed. These technical complications directly impact the cost efficiency of such solutions. Thus, limiting the wide range deployment of such technology. Henceforth, Optimal Sensor Placement (OSP) methodologies offers the possi-bility to optimize the sensor configuration that will ensure a proper and cost-efficient monitoring system to obtain the maximum modal information related to any infrastructure type.In this study, a novel "Modal Assurance Criterion (MAC)"-based methodology with the aim of the optimal sensor placement is presented using a 410 m high rise structure. The Modal Kinetic Energy (MKE) and a MAC -based objective function are combined in the suggested methodology. The optimization problem is solved using a new hybrid metaheuristic algorithm that combines Teaching-Learning-Based Optimization (TLBO), Artificial Bee Colonies (ABC), and Stochastic Paint Optimizer (SPO). With no user-defined parameters, the combination of algorithms exhibits up to 86% better fitness, avoids local optimums due to higher accuracy, and shows promising results for cost calculation optimization because it requires 50% to 70% fewer iterations compared to six evolutionary algorithms that are usually used.
引用
收藏
页码:1959 / 1971
页数:13
相关论文
共 50 条
  • [21] A Prototype Tool of Optimal Wireless Sensor Placement for Structural Health Monitoring
    Shi, Weixiang
    Wu, Changzhi
    Wang, Xiangyu
    ADVANCED COMPUTING STRATEGIES FOR ENGINEERING, PT II, 2018, 10864 : 53 - 73
  • [22] Acoustic Based Structural Health Monitoring for Composites Using Optimal Sensor Placement: Analysis and Experiments
    Das, Santanu
    Chattopadhyay, Aditi
    Zhou, Xu
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2009, 28 (01) : 83 - 97
  • [23] A Comparative Study of Genetic and Firefly Algorithms for Sensor Placement in Structural Health Monitoring
    Zhou, Guang-Dong
    Yi, Ting-Hua
    Zhang, Huan
    Li, Hong-Nan
    SHOCK AND VIBRATION, 2015, 2015
  • [24] Optimal placement of triaxial accelerometers using hypotrochoid spiral optimization algorithm for automated monitoring of high-rise buildings
    Mahjoubi, Soroush
    Barhemat, Rojyar
    Bao, Yi
    AUTOMATION IN CONSTRUCTION, 2020, 118
  • [25] A review on optimal sensor placement for health monitoring
    Liao CanXing
    Li Xingshan
    Zhang Ping
    Dai Jing
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 170 - 173
  • [26] A Generalized Optimal Sensor Placement Technique for Structural Health Monitoring and System Identification
    Rao, A. Rama Mohan
    Lakshmi, K.
    Krishnakumar, S.
    STRUCTURAL INTEGRITY, 2014, 86 : 529 - 538
  • [27] Optimal sensor placement for enhancing sensitivity to change in stiffness for structural health monitoring
    Josh M. Beal
    Amit Shukla
    Olga A. Brezhneva
    Mark A. Abramson
    Optimization and Engineering, 2008, 9 : 119 - 142
  • [28] A DISCRETE FIREFLY ALGORITHM FOR OPTIMAL WIRELESS SENSOR PLACEMENT IN STRUCTURAL HEALTH MONITORING
    Zhou, Guangdong
    Shen, Hui
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 1709 - 1715
  • [29] Optimal sensor placement for structural health monitoring based on deep reinforcement learning
    Meng, Xianghao
    Zhang, Haoyu
    Jia, Kailiang
    Li, Hui
    Huang, Yong
    SMART STRUCTURES AND SYSTEMS, 2023, 31 (03) : 247 - 257
  • [30] Optimal sensor placement for enhancing sensitivity to change in stiffness for structural health monitoring
    Beal, Josh M.
    Shukla, Amit
    Brezhneva, Olga A.
    Abramson, Mark A.
    OPTIMIZATION AND ENGINEERING, 2008, 9 (02) : 119 - 142