Effect of head rotation on two-dimensional cephalometric measurements using cone beam-computed tomography

被引:1
|
作者
El Hayeck, Emilie [1 ]
Bassil-Nassif, Nayla
Khairallah, Alexandre [2 ]
El Wak, Terry [3 ]
Bouserhal, Joseph [1 ,3 ,4 ]
机构
[1] St Joseph Univ, Sch Dent Med, Dept Orthodont, Beirut, Lebanon
[2] Lebanese Univ, Sch Dent, Dept Oral & Maxillo Facial Imaging, Beirut, Lebanon
[3] St Joseph Univ, Craniofacial Res Lab, Beirut, Lebanon
[4] Beirut Arab Univ, Sch Dent, Dept Orthodont, Beirut, Lebanon
关键词
Cone beam-computed tomography; Axial rotation; Lateral cephalograms; CBCT; PROJECTION ERRORS; ORIENTATION;
D O I
10.1007/s00784-022-04852-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The purpose of this study was to identify the variation of bi-dimensional cephalometric measurements following real head rotation. Material and methods Thirty cone beam-computed tomography (CBCT) head films were oriented according to three axes: horizontal Frankfort plane, transverse bi-orbital plane, and Opisthion-Nasion median plane. Axial rotation of 2 degrees, 4 degrees, 6 degrees, and 8 degrees from the Odontoidale point were performed. Horizontal and vertical linear and angular measurements were studied on lateral cephalograms derived from each rotation T0, T2, T4, T6, and T8. A paired t-test was applied to compare the measurements between T0 and each rotational angle. Results Of the 18 measurements, 55% showed statistically significant differences (P < 0.05) and 22% showed clinically significant differences, mostly at T6 and T8. Horizontal linear measurements Ba-A and N-Ba decreased, and vertical linear measurement G-Sn increased gradually, as the angle of head rotation increased. Angular measurements studied did not vary. Conclusions Head malpositions during X-ray acquisition should be avoided and rotated lateral CBCT cephalograms should be corrected and recentered to prevent any variation in linear measurements.
引用
收藏
页码:2747 / 2761
页数:15
相关论文
共 50 条
  • [31] Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography: A systematic review
    Sam, Alycia
    Currie, Kris
    Oh, Heesoo
    Flores-Mir, Carlos
    Lagravere-Vich, Manuel
    ANGLE ORTHODONTIST, 2019, 89 (02) : 317 - 332
  • [32] Head positioning in a cone beam computed tomography unit and the effect on accuracy of the three-dimensional surface mode
    Stamatakis, Harry C.
    Steegman, Ralph
    Dusseldorp, Joost
    Ren, Yijin
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2019, 127 (01) : 72 - 80
  • [33] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    R. Olszewski
    L. Frison
    M. Wisniewski
    J. M. Denis
    S. Vynckier
    G. Cosnard
    F. Zech
    H. Reychler
    Clinical Oral Investigations, 2013, 17 : 285 - 292
  • [34] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    Olszewski, R.
    Frison, L.
    Wisniewski, M.
    Denis, J. M.
    Vynckier, S.
    Cosnard, G.
    Zech, F.
    Reychler, H.
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 285 - 292
  • [35] Evaluating the four-dimensional cone beam computed tomography with varying gantry rotation speed
    Yoganathan, S. A.
    Maria, K. J.
    Ali, Shajahan Mohamed
    Agarwal, Arpita
    Mishra, Surendra P.
    Kumar, Shaleen
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1060):
  • [36] Dimensional stability in composite cone beam computed tomography
    Kopp, S.
    Ottl, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (08) : 512 - 516
  • [37] Accuracy and Repeatability of Anthropometric Facial Measurements Using Cone Beam Computed Tomography
    Fourie, Zacharias
    Damstra, Janalt
    Gerrits, Peter O.
    Ren, Yijin
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2011, 48 (05): : 623 - 630
  • [38] Cone Beam Computed Tomography Dose Measurements. Head & Neck Collimators in Elekta Synergy®
    Juan-Senabre, X.
    Lopez-Tarjuelo, J.
    Santos-Serra, A.
    Calzada-Feliu, S.
    Sanfeliu-Lucas, E.
    MEDICAL PHYSICS, 2010, 37 (06) : 3160 - +
  • [39] Accuracy of Linear Measurements of Galileos Cone Beam Computed Tomography in Normal and Different Head Positions
    Sheikhi, Mahnaz
    Ghorbanizadeh, Sajad
    Abdinian, Mehrdad
    Goroohi, Hossein
    Badrian, Hamid
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [40] Two-Dimensional and Three-Dimensional Cephalometry Using Cone Beam Computed Tomography Scans (vol 26, pg e311, 2015)
    Cassetta, Michele
    Altieri, Federica
    Di Giorgio, Roberto
    Silvestri, Alessandro
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (06) : e560 - e560